Non-Invasive Glucose Monitoring Based on Mid-Infrared Spectroscopy
This paper presents on non-invasive method of glucose monitoring using Mid-Infrared (M-IR) spectroscopy. Glucose samples are prepared and analyzed using M-IR spectroscopy. Using Fourier-transform of the M-IR spectroscopy, we experimentally track variations in the mid-infrared glucose absorption peak...
Published in: | Proceedings of International Conference on Artificial Life and Robotics |
---|---|
Main Author: | |
Format: | Conference paper |
Language: | English |
Published: |
ALife Robotics Corporation Ltd
2025
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85219577680&partnerID=40&md5=0d527869f0016d5690a928e385ba2ac4 |
id |
Zakki P.N.S.M.; Naim N.F.; Saad H.; Muhamad W.N.W.; Sarnin S.S.; Ya’acob N.; Abu Bakar N.F. |
---|---|
spelling |
Zakki P.N.S.M.; Naim N.F.; Saad H.; Muhamad W.N.W.; Sarnin S.S.; Ya’acob N.; Abu Bakar N.F. 2-s2.0-85219577680 Non-Invasive Glucose Monitoring Based on Mid-Infrared Spectroscopy 2025 Proceedings of International Conference on Artificial Life and Robotics https://www.scopus.com/inward/record.uri?eid=2-s2.0-85219577680&partnerID=40&md5=0d527869f0016d5690a928e385ba2ac4 This paper presents on non-invasive method of glucose monitoring using Mid-Infrared (M-IR) spectroscopy. Glucose samples are prepared and analyzed using M-IR spectroscopy. Using Fourier-transform of the M-IR spectroscopy, we experimentally track variations in the mid-infrared glucose absorption peak. The glucose samples and the relation with diabetic people is also presented in this paper. It is found that as the glucose concentration increases, the wavelengths at which absorbance peaks occur also increase particularly for wavelength range 1400-1470nm. © The 2025 International Conference on Artificial Life and Robotics (ICAROB2025). ALife Robotics Corporation Ltd 24359157 English Conference paper |
author |
2-s2.0-85219577680 |
spellingShingle |
2-s2.0-85219577680 Non-Invasive Glucose Monitoring Based on Mid-Infrared Spectroscopy |
author_facet |
2-s2.0-85219577680 |
author_sort |
2-s2.0-85219577680 |
title |
Non-Invasive Glucose Monitoring Based on Mid-Infrared Spectroscopy |
title_short |
Non-Invasive Glucose Monitoring Based on Mid-Infrared Spectroscopy |
title_full |
Non-Invasive Glucose Monitoring Based on Mid-Infrared Spectroscopy |
title_fullStr |
Non-Invasive Glucose Monitoring Based on Mid-Infrared Spectroscopy |
title_full_unstemmed |
Non-Invasive Glucose Monitoring Based on Mid-Infrared Spectroscopy |
title_sort |
Non-Invasive Glucose Monitoring Based on Mid-Infrared Spectroscopy |
publishDate |
2025 |
container_title |
Proceedings of International Conference on Artificial Life and Robotics |
container_volume |
|
container_issue |
|
doi_str_mv |
|
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85219577680&partnerID=40&md5=0d527869f0016d5690a928e385ba2ac4 |
description |
This paper presents on non-invasive method of glucose monitoring using Mid-Infrared (M-IR) spectroscopy. Glucose samples are prepared and analyzed using M-IR spectroscopy. Using Fourier-transform of the M-IR spectroscopy, we experimentally track variations in the mid-infrared glucose absorption peak. The glucose samples and the relation with diabetic people is also presented in this paper. It is found that as the glucose concentration increases, the wavelengths at which absorbance peaks occur also increase particularly for wavelength range 1400-1470nm. © The 2025 International Conference on Artificial Life and Robotics (ICAROB2025). |
publisher |
ALife Robotics Corporation Ltd |
issn |
24359157 |
language |
English |
format |
Conference paper |
accesstype |
|
record_format |
scopus |
collection |
Scopus |
_version_ |
1828987858080235520 |