Comparison of vergence mechanisms between university students with good and poor sleep quality

• AIM: To compare the vergence mechanisms between good and poor sleepers in university students. • METHODS: A total of 64 university students were recruited in this study. The validated Malay version of Pittsburgh Sleep Quality Index questionnaire (PSQI-M) was used to measure the participants’ sleep...

全面介绍

书目详细资料
发表在:International Journal of Ophthalmology
主要作者: 2-s2.0-85186228708
格式: 文件
语言:English
出版: International Journal of Ophthalmology (c/o Editorial Office) 2024
在线阅读:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85186228708&doi=10.18240%2fijo.2024.02.19&partnerID=40&md5=a00ff6e181808c231d072eab90d3e1b4
id Woi P.J.; Lu J.Y.L.; Hairol M.I.; Ibrahim W.N.A.
spelling Woi P.J.; Lu J.Y.L.; Hairol M.I.; Ibrahim W.N.A.
2-s2.0-85186228708
Comparison of vergence mechanisms between university students with good and poor sleep quality
2024
International Journal of Ophthalmology
17
2
10.18240/ijo.2024.02.19
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85186228708&doi=10.18240%2fijo.2024.02.19&partnerID=40&md5=a00ff6e181808c231d072eab90d3e1b4
• AIM: To compare the vergence mechanisms between good and poor sleepers in university students. • METHODS: A total of 64 university students were recruited in this study. The validated Malay version of Pittsburgh Sleep Quality Index questionnaire (PSQI-M) was used to measure the participants’ sleep quality over the past month. Participants were categorized as good sleepers (n=32) and poor sleepers (n=32) based on the PSQI-M scores. Heterophoria and fusional vergences were measured at distance and near. Mann-Whitney U test was used to compare heterophoria, negative fusional vergence (NFV), and positive fusional vergence (PFV) at distance and near between good and poor sleepers. Spearman correlation analysis was used to study the relationship between PSQI-M score and PFV at distance. • RESULTS: Both distance and near heterophorias were not significantly different between good and poor sleepers (P>0.05). There was a difference in distance PFV (P<0.05) between good and poor sleepers, but not in distance NFV, near NFV, and near PFV (P>0.05). Distance PFV was negatively correlated with PSQI-M score (rs=-0.33, P<0.05). • CONCLUSION: University students with poor sleep quality demonstrates a reduced ability to maintain fusion with increasing convergence demand at distance. Sleep quality assessment during binocular vision examination in university students is recommended. © 2024 International Journal of Ophthalmology (c/o Editorial Office). All rights reserved.
International Journal of Ophthalmology (c/o Editorial Office)
22223959
English
Article
All Open Access; Gold Open Access; Green Open Access
author 2-s2.0-85186228708
spellingShingle 2-s2.0-85186228708
Comparison of vergence mechanisms between university students with good and poor sleep quality
author_facet 2-s2.0-85186228708
author_sort 2-s2.0-85186228708
title Comparison of vergence mechanisms between university students with good and poor sleep quality
title_short Comparison of vergence mechanisms between university students with good and poor sleep quality
title_full Comparison of vergence mechanisms between university students with good and poor sleep quality
title_fullStr Comparison of vergence mechanisms between university students with good and poor sleep quality
title_full_unstemmed Comparison of vergence mechanisms between university students with good and poor sleep quality
title_sort Comparison of vergence mechanisms between university students with good and poor sleep quality
publishDate 2024
container_title International Journal of Ophthalmology
container_volume 17
container_issue 2
doi_str_mv 10.18240/ijo.2024.02.19
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85186228708&doi=10.18240%2fijo.2024.02.19&partnerID=40&md5=a00ff6e181808c231d072eab90d3e1b4
description • AIM: To compare the vergence mechanisms between good and poor sleepers in university students. • METHODS: A total of 64 university students were recruited in this study. The validated Malay version of Pittsburgh Sleep Quality Index questionnaire (PSQI-M) was used to measure the participants’ sleep quality over the past month. Participants were categorized as good sleepers (n=32) and poor sleepers (n=32) based on the PSQI-M scores. Heterophoria and fusional vergences were measured at distance and near. Mann-Whitney U test was used to compare heterophoria, negative fusional vergence (NFV), and positive fusional vergence (PFV) at distance and near between good and poor sleepers. Spearman correlation analysis was used to study the relationship between PSQI-M score and PFV at distance. • RESULTS: Both distance and near heterophorias were not significantly different between good and poor sleepers (P>0.05). There was a difference in distance PFV (P<0.05) between good and poor sleepers, but not in distance NFV, near NFV, and near PFV (P>0.05). Distance PFV was negatively correlated with PSQI-M score (rs=-0.33, P<0.05). • CONCLUSION: University students with poor sleep quality demonstrates a reduced ability to maintain fusion with increasing convergence demand at distance. Sleep quality assessment during binocular vision examination in university students is recommended. © 2024 International Journal of Ophthalmology (c/o Editorial Office). All rights reserved.
publisher International Journal of Ophthalmology (c/o Editorial Office)
issn 22223959
language English
format Article
accesstype All Open Access; Gold Open Access; Green Open Access
record_format scopus
collection Scopus
_version_ 1828987863295852544