Flexural Behavior of Built-Up Cold-formed Steel Channel Section Strengthened with Oriented Strand Board

The objective of the study is to determine the flexural behavior of the built-up cold-formed steel (CFS) channel section strengthened with an oriented strand board (OSB) in the three-point bending experiment. CFS with a variety of shapes and grades is classified as a steel-based material and exposed...

Full description

Bibliographic Details
Published in:International Journal of Engineering and Technology Innovation
Main Author: 2-s2.0-85165964149
Format: Article
Language:English
Published: Taiwan Association of Engineering and Technology Innovation 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85165964149&doi=10.46604%2fijeti.2023.11380&partnerID=40&md5=ea87767202a741b7d802881cb890b4bb
id Sani M.S.H.M.; Amaruddin H.I.; Rahman W.M.N.W.A.; Muftah F.
spelling Sani M.S.H.M.; Amaruddin H.I.; Rahman W.M.N.W.A.; Muftah F.
2-s2.0-85165964149
Flexural Behavior of Built-Up Cold-formed Steel Channel Section Strengthened with Oriented Strand Board
2023
International Journal of Engineering and Technology Innovation
13
3
10.46604/ijeti.2023.11380
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85165964149&doi=10.46604%2fijeti.2023.11380&partnerID=40&md5=ea87767202a741b7d802881cb890b4bb
The objective of the study is to determine the flexural behavior of the built-up cold-formed steel (CFS) channel section strengthened with an oriented strand board (OSB) in the three-point bending experiment. CFS with a variety of shapes and grades is classified as a steel-based material and exposed to buckling failure when subjected to compression or flexural load. Thus, the CFS channel section with 100 mm of the web, 50 mm of the flange, 12 mm of the lip, and 1.55 mm of thickness has been selected. Then, the built-up CFS channel section is designed by filling with an OSB between the gap of each section. Channel, face-to-face built-up, and back-to-back built-up CFS sections are three types of tested specimens. From the result and discussion, the specimen with back-to-back built-up CFS section is recognized to sustain the ultimate load with the highest value when compared with other specimens. © 2023 by the authors. Licensee TAETI, Taiwan. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY-NC) license (https://creativecommons.org/licenses/by-nc/4.0/)., All Rights Reserved.
Taiwan Association of Engineering and Technology Innovation
22235329
English
Article
All Open Access; Gold Open Access
author 2-s2.0-85165964149
spellingShingle 2-s2.0-85165964149
Flexural Behavior of Built-Up Cold-formed Steel Channel Section Strengthened with Oriented Strand Board
author_facet 2-s2.0-85165964149
author_sort 2-s2.0-85165964149
title Flexural Behavior of Built-Up Cold-formed Steel Channel Section Strengthened with Oriented Strand Board
title_short Flexural Behavior of Built-Up Cold-formed Steel Channel Section Strengthened with Oriented Strand Board
title_full Flexural Behavior of Built-Up Cold-formed Steel Channel Section Strengthened with Oriented Strand Board
title_fullStr Flexural Behavior of Built-Up Cold-formed Steel Channel Section Strengthened with Oriented Strand Board
title_full_unstemmed Flexural Behavior of Built-Up Cold-formed Steel Channel Section Strengthened with Oriented Strand Board
title_sort Flexural Behavior of Built-Up Cold-formed Steel Channel Section Strengthened with Oriented Strand Board
publishDate 2023
container_title International Journal of Engineering and Technology Innovation
container_volume 13
container_issue 3
doi_str_mv 10.46604/ijeti.2023.11380
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85165964149&doi=10.46604%2fijeti.2023.11380&partnerID=40&md5=ea87767202a741b7d802881cb890b4bb
description The objective of the study is to determine the flexural behavior of the built-up cold-formed steel (CFS) channel section strengthened with an oriented strand board (OSB) in the three-point bending experiment. CFS with a variety of shapes and grades is classified as a steel-based material and exposed to buckling failure when subjected to compression or flexural load. Thus, the CFS channel section with 100 mm of the web, 50 mm of the flange, 12 mm of the lip, and 1.55 mm of thickness has been selected. Then, the built-up CFS channel section is designed by filling with an OSB between the gap of each section. Channel, face-to-face built-up, and back-to-back built-up CFS sections are three types of tested specimens. From the result and discussion, the specimen with back-to-back built-up CFS section is recognized to sustain the ultimate load with the highest value when compared with other specimens. © 2023 by the authors. Licensee TAETI, Taiwan. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY-NC) license (https://creativecommons.org/licenses/by-nc/4.0/)., All Rights Reserved.
publisher Taiwan Association of Engineering and Technology Innovation
issn 22235329
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1828987866691141632