Effect of different preheating's temperature towards the integrity of weldment AISI 1045

The purpose of this paper is to show the effect of different preheating's temperature for different thickness of AISI 1045 before it was welded by using Shield Metal Arc Welding (SMAW). The temperature of preheating approach that will be use are 200oC, 250oC and 300oC and were applied to pair o...

وصف كامل

التفاصيل البيبلوغرافية
الحاوية / القاعدة:IOP Conference Series: Materials Science and Engineering
المؤلف الرئيسي: 2-s2.0-85087506656
التنسيق: Conference paper
اللغة:English
منشور في: Institute of Physics Publishing 2020
الوصول للمادة أونلاين:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85087506656&doi=10.1088%2f1757-899X%2f834%2f1%2f012070&partnerID=40&md5=fb801ea8ae0f50b64140e616e9e33bcf
id Mat Shah M.A.; Rosli F.H.; Abdullah B.; Alias S.K.; Hamami G.; Halmy M.N.
spelling Mat Shah M.A.; Rosli F.H.; Abdullah B.; Alias S.K.; Hamami G.; Halmy M.N.
2-s2.0-85087506656
Effect of different preheating's temperature towards the integrity of weldment AISI 1045
2020
IOP Conference Series: Materials Science and Engineering
834
1
10.1088/1757-899X/834/1/012070
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85087506656&doi=10.1088%2f1757-899X%2f834%2f1%2f012070&partnerID=40&md5=fb801ea8ae0f50b64140e616e9e33bcf
The purpose of this paper is to show the effect of different preheating's temperature for different thickness of AISI 1045 before it was welded by using Shield Metal Arc Welding (SMAW). The temperature of preheating approach that will be use are 200oC, 250oC and 300oC and were applied to pair of base plate metal with different thickness of 16mm, 22mm and 28mm. Then the pair samples had been welded by using Shield Metal Arc Welding (SMAW). To monitoring the temperature, non-contact type instrument which is thermomapping was used in this study. Time was recorded after preheating was applied and then was stopped when the desired temperature has been obtained. As to evaluate the weld quality, the macrostructure observation, dye penetration, hardness, and tensile test were conducted. As the result, it found that the electrode rod with size16mm and 22mm required preheating's temperature around 200° C while for 28mm required temperature up to 250°C. This paper will give a deeper understanding about the effect of preheating in term of strength of joining. The result obtained from this study can be used to assist welder while performing welding on medium carbon steel. © 2020 IOP Publishing Ltd. All rights reserved.
Institute of Physics Publishing
17578981
English
Conference paper
All Open Access; Gold Open Access
author 2-s2.0-85087506656
spellingShingle 2-s2.0-85087506656
Effect of different preheating's temperature towards the integrity of weldment AISI 1045
author_facet 2-s2.0-85087506656
author_sort 2-s2.0-85087506656
title Effect of different preheating's temperature towards the integrity of weldment AISI 1045
title_short Effect of different preheating's temperature towards the integrity of weldment AISI 1045
title_full Effect of different preheating's temperature towards the integrity of weldment AISI 1045
title_fullStr Effect of different preheating's temperature towards the integrity of weldment AISI 1045
title_full_unstemmed Effect of different preheating's temperature towards the integrity of weldment AISI 1045
title_sort Effect of different preheating's temperature towards the integrity of weldment AISI 1045
publishDate 2020
container_title IOP Conference Series: Materials Science and Engineering
container_volume 834
container_issue 1
doi_str_mv 10.1088/1757-899X/834/1/012070
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85087506656&doi=10.1088%2f1757-899X%2f834%2f1%2f012070&partnerID=40&md5=fb801ea8ae0f50b64140e616e9e33bcf
description The purpose of this paper is to show the effect of different preheating's temperature for different thickness of AISI 1045 before it was welded by using Shield Metal Arc Welding (SMAW). The temperature of preheating approach that will be use are 200oC, 250oC and 300oC and were applied to pair of base plate metal with different thickness of 16mm, 22mm and 28mm. Then the pair samples had been welded by using Shield Metal Arc Welding (SMAW). To monitoring the temperature, non-contact type instrument which is thermomapping was used in this study. Time was recorded after preheating was applied and then was stopped when the desired temperature has been obtained. As to evaluate the weld quality, the macrostructure observation, dye penetration, hardness, and tensile test were conducted. As the result, it found that the electrode rod with size16mm and 22mm required preheating's temperature around 200° C while for 28mm required temperature up to 250°C. This paper will give a deeper understanding about the effect of preheating in term of strength of joining. The result obtained from this study can be used to assist welder while performing welding on medium carbon steel. © 2020 IOP Publishing Ltd. All rights reserved.
publisher Institute of Physics Publishing
issn 17578981
language English
format Conference paper
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1828987872432095232