Three probe reflectometer algorithm for complex coefficient measurements of water quality at microwave frequencies
The complex reflection coefficient (magnitude and phase) are measured using a three probe reflectometer algorithm. The measurement system consists of a Gunn diode source, 1 kHz modulator, attenuator, slotted line, A/D converter and a computer. A slotted line is used to measure three standing wave vo...
الحاوية / القاعدة: | 2003 Asia-Pacific Conference on Applied Electromagnetics, APACE 2003 - Proceedings |
---|---|
المؤلف الرئيسي: | |
التنسيق: | Conference paper |
اللغة: | English |
منشور في: |
Institute of Electrical and Electronics Engineers Inc.
2003
|
الوصول للمادة أونلاين: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84946397624&doi=10.1109%2fAPACE.2003.1234481&partnerID=40&md5=12e4b6203a19a452eb3233c27a71248d |
الملخص: | The complex reflection coefficient (magnitude and phase) are measured using a three probe reflectometer algorithm. The measurement system consists of a Gunn diode source, 1 kHz modulator, attenuator, slotted line, A/D converter and a computer. A slotted line is used to measure three standing wave voltages corresponding to three probe positions which are one-eighth wavelength apart. Complex reflection coefficient results are reported for two standard liquids, namely, water and methyl alcohol. This measurement system can be used for water quality measurements. © 2003 IEEE. |
---|---|
تدمد: | |
DOI: | 10.1109/APACE.2003.1234481 |