Real-time forest fire detection, monitoring, and alert system using Arduino

Early fire detection is critical to protecting forests from wildfires and enabling rapid responses to minimize fire spread. Existing forest fire detection methods cannot quickly detect forest fires and evaluate the fire risk of these sensitive areas. Hence, this research aims to develop a real-time...

وصف كامل

التفاصيل البيبلوغرافية
الحاوية / القاعدة:Indonesian Journal of Electrical Engineering and Computer Science
المؤلف الرئيسي: 2-s2.0-85184615110
التنسيق: مقال
اللغة:English
منشور في: Institute of Advanced Engineering and Science 2024
الوصول للمادة أونلاين:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85184615110&doi=10.11591%2fijeecs.v33.i2.pp942-950&partnerID=40&md5=dab0196cc55ea95a57cfb442d2e63852
id Anuar A.I.M.; Mohamad R.; Markom A.M.; Concepcion R.
spelling Anuar A.I.M.; Mohamad R.; Markom A.M.; Concepcion R.
2-s2.0-85184615110
Real-time forest fire detection, monitoring, and alert system using Arduino
2024
Indonesian Journal of Electrical Engineering and Computer Science
33
2
10.11591/ijeecs.v33.i2.pp942-950
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85184615110&doi=10.11591%2fijeecs.v33.i2.pp942-950&partnerID=40&md5=dab0196cc55ea95a57cfb442d2e63852
Early fire detection is critical to protecting forests from wildfires and enabling rapid responses to minimize fire spread. Existing forest fire detection methods cannot quickly detect forest fires and evaluate the fire risk of these sensitive areas. Hence, this research aims to develop a real-time forest fire detection, monitoring, and alert system. The development of the system started with assembling temperature and humidity sensors, a smoke sensor, an Arduino microcontroller, and a wireless fidelity module. Then, a fire monitoring and alert system was developed using Blynk. From the sensitivity flame sensor analysis with the fire, the flame sensor detected the presence of fire up to 60 cm. The sensor also indicated high temperature (45 °C) and low humidity (53.4%) at noon. Low temperature (29 ℃) and high humidity (88.4%) were identified in the morning. Moreover, the highest carbon dioxide (CO2) concentration of 1,800 ppm was recorded when the smoke from the fire was detected. The global positioning system module shows the accurate real-time location of the system displayed in the Blynk application. In conclusion, this system can detect and monitor early forest fires in real-time and can alert the authorities to protect forests from wildfires. © 2024 Institute of Advanced Engineering and Science. All rights reserved.
Institute of Advanced Engineering and Science
25024752
English
Article
All Open Access; Gold Open Access
author 2-s2.0-85184615110
spellingShingle 2-s2.0-85184615110
Real-time forest fire detection, monitoring, and alert system using Arduino
author_facet 2-s2.0-85184615110
author_sort 2-s2.0-85184615110
title Real-time forest fire detection, monitoring, and alert system using Arduino
title_short Real-time forest fire detection, monitoring, and alert system using Arduino
title_full Real-time forest fire detection, monitoring, and alert system using Arduino
title_fullStr Real-time forest fire detection, monitoring, and alert system using Arduino
title_full_unstemmed Real-time forest fire detection, monitoring, and alert system using Arduino
title_sort Real-time forest fire detection, monitoring, and alert system using Arduino
publishDate 2024
container_title Indonesian Journal of Electrical Engineering and Computer Science
container_volume 33
container_issue 2
doi_str_mv 10.11591/ijeecs.v33.i2.pp942-950
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85184615110&doi=10.11591%2fijeecs.v33.i2.pp942-950&partnerID=40&md5=dab0196cc55ea95a57cfb442d2e63852
description Early fire detection is critical to protecting forests from wildfires and enabling rapid responses to minimize fire spread. Existing forest fire detection methods cannot quickly detect forest fires and evaluate the fire risk of these sensitive areas. Hence, this research aims to develop a real-time forest fire detection, monitoring, and alert system. The development of the system started with assembling temperature and humidity sensors, a smoke sensor, an Arduino microcontroller, and a wireless fidelity module. Then, a fire monitoring and alert system was developed using Blynk. From the sensitivity flame sensor analysis with the fire, the flame sensor detected the presence of fire up to 60 cm. The sensor also indicated high temperature (45 °C) and low humidity (53.4%) at noon. Low temperature (29 ℃) and high humidity (88.4%) were identified in the morning. Moreover, the highest carbon dioxide (CO2) concentration of 1,800 ppm was recorded when the smoke from the fire was detected. The global positioning system module shows the accurate real-time location of the system displayed in the Blynk application. In conclusion, this system can detect and monitor early forest fires in real-time and can alert the authorities to protect forests from wildfires. © 2024 Institute of Advanced Engineering and Science. All rights reserved.
publisher Institute of Advanced Engineering and Science
issn 25024752
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1828987860936556544