Hysteresis loops of base isolation system-an overview
Recently, there are a lot of technological developments in the earthquake engineering field to reduce structural damage and one of them is base isolation system. Base isolation system is one of the best technologies for the safety of human beings and properties under earthquake excitations. The aim...
出版年: | Key Engineering Materials |
---|---|
第一著者: | |
フォーマット: | Conference paper |
言語: | English |
出版事項: |
Trans Tech Publications Ltd
2021
|
オンライン・アクセス: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85104346296&doi=10.4028%2fwww.scientific.net%2fKEM.879.189&partnerID=40&md5=6d7d57e4e0aa532b90b660118fb38fec |
id |
Amir M.A.; Hamid N.H. |
---|---|
spelling |
Amir M.A.; Hamid N.H. 2-s2.0-85104346296 Hysteresis loops of base isolation system-an overview 2021 Key Engineering Materials 879 KEM 10.4028/www.scientific.net/KEM.879.189 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85104346296&doi=10.4028%2fwww.scientific.net%2fKEM.879.189&partnerID=40&md5=6d7d57e4e0aa532b90b660118fb38fec Recently, there are a lot of technological developments in the earthquake engineering field to reduce structural damage and one of them is base isolation system. Base isolation system is one of the best technologies for the safety of human beings and properties under earthquake excitations. The aim of this paper is to review previous research works on simulation of base isolation systems for RC buildings and their efficiency on the safety of these buildings. Base isolation decouples superstructure from substructure to avoid transmission of seismic energy to the superstructure of RC buildings. The most effective way to assess the of base isolation system for RC building under different earthquake excitations is by conducting experiment work that consume more time and money. Many researchers had studied the behavior of base isolation system for structure through modeling the behavior of the base isolation in which base isolator is modeled through numerical models and validated through experimental works. Previous researches on the modeling of base isolation systems of structures had shown similar outcomes as the experimental work. These studies indicate that base isolation is an effective technology in immunization of structures against earthquakes. © 2021 Trans Tech Publications Ltd, Switzerland. Trans Tech Publications Ltd 10139826 English Conference paper |
author |
2-s2.0-85104346296 |
spellingShingle |
2-s2.0-85104346296 Hysteresis loops of base isolation system-an overview |
author_facet |
2-s2.0-85104346296 |
author_sort |
2-s2.0-85104346296 |
title |
Hysteresis loops of base isolation system-an overview |
title_short |
Hysteresis loops of base isolation system-an overview |
title_full |
Hysteresis loops of base isolation system-an overview |
title_fullStr |
Hysteresis loops of base isolation system-an overview |
title_full_unstemmed |
Hysteresis loops of base isolation system-an overview |
title_sort |
Hysteresis loops of base isolation system-an overview |
publishDate |
2021 |
container_title |
Key Engineering Materials |
container_volume |
879 KEM |
container_issue |
|
doi_str_mv |
10.4028/www.scientific.net/KEM.879.189 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85104346296&doi=10.4028%2fwww.scientific.net%2fKEM.879.189&partnerID=40&md5=6d7d57e4e0aa532b90b660118fb38fec |
description |
Recently, there are a lot of technological developments in the earthquake engineering field to reduce structural damage and one of them is base isolation system. Base isolation system is one of the best technologies for the safety of human beings and properties under earthquake excitations. The aim of this paper is to review previous research works on simulation of base isolation systems for RC buildings and their efficiency on the safety of these buildings. Base isolation decouples superstructure from substructure to avoid transmission of seismic energy to the superstructure of RC buildings. The most effective way to assess the of base isolation system for RC building under different earthquake excitations is by conducting experiment work that consume more time and money. Many researchers had studied the behavior of base isolation system for structure through modeling the behavior of the base isolation in which base isolator is modeled through numerical models and validated through experimental works. Previous researches on the modeling of base isolation systems of structures had shown similar outcomes as the experimental work. These studies indicate that base isolation is an effective technology in immunization of structures against earthquakes. © 2021 Trans Tech Publications Ltd, Switzerland. |
publisher |
Trans Tech Publications Ltd |
issn |
10139826 |
language |
English |
format |
Conference paper |
accesstype |
|
record_format |
scopus |
collection |
Scopus |
_version_ |
1828987871376179200 |