Initial quantitative comparison of 940nm and 950nm infrared sensor performance for measuring glucose non-invasively

This project uses a non-invasive method for measuring the blood glucose concentration levels. By implementing two infrared light with different wavelength; 940nm and 950nm based on the use of light emitting diodes and measure transmittance through solution of distilled water and d-glucose of concent...

وصف كامل

التفاصيل البيبلوغرافية
الحاوية / القاعدة:2013 IEEE International Conference on Smart Instrumentation, Measurement and Applications, ICSIMA 2013
المؤلف الرئيسي: 2-s2.0-84894147715
التنسيق: Conference paper
اللغة:English
منشور في: 2013
الوصول للمادة أونلاين:https://www.scopus.com/inward/record.uri?eid=2-s2.0-84894147715&doi=10.1109%2fICSIMA.2013.6717938&partnerID=40&md5=c5e15c08d8c44e8275625d69bcf1d7ff
id Abidin M.T.B.Z.; Rosli M.K.R.; Shamsuddin S.A.; Madzhi N.K.; Abdullah M.F.
spelling Abidin M.T.B.Z.; Rosli M.K.R.; Shamsuddin S.A.; Madzhi N.K.; Abdullah M.F.
2-s2.0-84894147715
Initial quantitative comparison of 940nm and 950nm infrared sensor performance for measuring glucose non-invasively
2013
2013 IEEE International Conference on Smart Instrumentation, Measurement and Applications, ICSIMA 2013


10.1109/ICSIMA.2013.6717938
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84894147715&doi=10.1109%2fICSIMA.2013.6717938&partnerID=40&md5=c5e15c08d8c44e8275625d69bcf1d7ff
This project uses a non-invasive method for measuring the blood glucose concentration levels. By implementing two infrared light with different wavelength; 940nm and 950nm based on the use of light emitting diodes and measure transmittance through solution of distilled water and d-glucose of concentration from 0mg/dL to 200mg/dL by using a 1000nm photodiode. It is observed that the output voltage from the photodiode increased proportionally to the increased of concentration levels. The relation observed was linear. Nine subjects with the same age but different body weight have been used to observe the glucose level during fasting and non-fasting. During fasting the voltage is about 0.13096V to 0.236V and during non-fasting the voltage range is about 0.12V to 0.256V. This method of measuring blood glucose level may become a preferably choice for diabetics because of the non-invasive and may extend to the general public. For having a large majority people able to monitor their blood glucose levels, it may prevent hypoglycemia, hyperglycemia and perhaps the onset of diabetes. © 2013 IEEE.


English
Conference paper

author 2-s2.0-84894147715
spellingShingle 2-s2.0-84894147715
Initial quantitative comparison of 940nm and 950nm infrared sensor performance for measuring glucose non-invasively
author_facet 2-s2.0-84894147715
author_sort 2-s2.0-84894147715
title Initial quantitative comparison of 940nm and 950nm infrared sensor performance for measuring glucose non-invasively
title_short Initial quantitative comparison of 940nm and 950nm infrared sensor performance for measuring glucose non-invasively
title_full Initial quantitative comparison of 940nm and 950nm infrared sensor performance for measuring glucose non-invasively
title_fullStr Initial quantitative comparison of 940nm and 950nm infrared sensor performance for measuring glucose non-invasively
title_full_unstemmed Initial quantitative comparison of 940nm and 950nm infrared sensor performance for measuring glucose non-invasively
title_sort Initial quantitative comparison of 940nm and 950nm infrared sensor performance for measuring glucose non-invasively
publishDate 2013
container_title 2013 IEEE International Conference on Smart Instrumentation, Measurement and Applications, ICSIMA 2013
container_volume
container_issue
doi_str_mv 10.1109/ICSIMA.2013.6717938
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-84894147715&doi=10.1109%2fICSIMA.2013.6717938&partnerID=40&md5=c5e15c08d8c44e8275625d69bcf1d7ff
description This project uses a non-invasive method for measuring the blood glucose concentration levels. By implementing two infrared light with different wavelength; 940nm and 950nm based on the use of light emitting diodes and measure transmittance through solution of distilled water and d-glucose of concentration from 0mg/dL to 200mg/dL by using a 1000nm photodiode. It is observed that the output voltage from the photodiode increased proportionally to the increased of concentration levels. The relation observed was linear. Nine subjects with the same age but different body weight have been used to observe the glucose level during fasting and non-fasting. During fasting the voltage is about 0.13096V to 0.236V and during non-fasting the voltage range is about 0.12V to 0.256V. This method of measuring blood glucose level may become a preferably choice for diabetics because of the non-invasive and may extend to the general public. For having a large majority people able to monitor their blood glucose levels, it may prevent hypoglycemia, hyperglycemia and perhaps the onset of diabetes. © 2013 IEEE.
publisher
issn
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1828987882830823424