Advancements in Spasticity Management: A Design Framework with PID Integration for Upper Limb Spasticity Training Device (ULSTraD)

The upper limb spasticity training device (ULSTraD) is a simulator designed to replicate various spasticity behaviors observed in patients with upper limb spasticity. Through a systematic development process involving requirements analysis, clinical data collection, conceptual design, prototyping, a...

Full description

Bibliographic Details
Published in:2024 2nd International Conference on Mechatronics, Control and Robotics, ICMCR 2024
Main Author: Othman N.A.; Zakaria N.A.C.; Low C.Y.; Hashim N.M.; Johar K.; Zohadi M.A.M.; Yee J.; Hanapiah F.A.
Format: Conference paper
Language:English
Published: Institute of Electrical and Electronics Engineers Inc. 2024
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85190514108&doi=10.1109%2fICMCR60777.2024.10481838&partnerID=40&md5=34d36a9bcf9f342fbef96dd26bdd333e
id 2-s2.0-85190514108
spelling 2-s2.0-85190514108
Othman N.A.; Zakaria N.A.C.; Low C.Y.; Hashim N.M.; Johar K.; Zohadi M.A.M.; Yee J.; Hanapiah F.A.
Advancements in Spasticity Management: A Design Framework with PID Integration for Upper Limb Spasticity Training Device (ULSTraD)
2024
2024 2nd International Conference on Mechatronics, Control and Robotics, ICMCR 2024


10.1109/ICMCR60777.2024.10481838
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85190514108&doi=10.1109%2fICMCR60777.2024.10481838&partnerID=40&md5=34d36a9bcf9f342fbef96dd26bdd333e
The upper limb spasticity training device (ULSTraD) is a simulator designed to replicate various spasticity behaviors observed in patients with upper limb spasticity. Through a systematic development process involving requirements analysis, clinical data collection, conceptual design, prototyping, and integration of a Proportional-Integral-Derivative (PID) controller, the ULSTraD achieves precise control over servo motors. The PID controller, in conjunction with the PWM Controller PCA9885 and real-time feedback from the MPU6050 angle sensor, enables accurate spasticity behavior emulation. Optimal PID gains (Kp = 0.9, Ki = 1.0, and Kd = 0.00) were determined through tuning, resulting in the desired target position. By incorporating FSR 460 and conducting tests at various angles using the PID controller, ULSTraD displayed real-time responsiveness to external forces, enhancing its stability and accurately emulating upper limb spasticity behaviors. Guided by anthropometric measurements and clinical data, the ULSTraD closely resembles a real human arm affected by spasticity. The prototyping process involved 3D printing, welding, and assembly, leading to a functional prototype refined through iterative testing. To assess the similarity in range of motion (ROM) between ULSTraD and the human arm, a Paired Sample T-test was conducted, comparing the flexion and extension movements. The obtained p-value from the test was 0.9087, which indicates that there is no statistically significant difference in ROM between ULSTraD and the human arm during both flexion and extension movements. This validates ULSTraD's ability to replicate the human arm's range of motion affected by spasticity. © 2024 IEEE.
Institute of Electrical and Electronics Engineers Inc.

English
Conference paper

author Othman N.A.; Zakaria N.A.C.; Low C.Y.; Hashim N.M.; Johar K.; Zohadi M.A.M.; Yee J.; Hanapiah F.A.
spellingShingle Othman N.A.; Zakaria N.A.C.; Low C.Y.; Hashim N.M.; Johar K.; Zohadi M.A.M.; Yee J.; Hanapiah F.A.
Advancements in Spasticity Management: A Design Framework with PID Integration for Upper Limb Spasticity Training Device (ULSTraD)
author_facet Othman N.A.; Zakaria N.A.C.; Low C.Y.; Hashim N.M.; Johar K.; Zohadi M.A.M.; Yee J.; Hanapiah F.A.
author_sort Othman N.A.; Zakaria N.A.C.; Low C.Y.; Hashim N.M.; Johar K.; Zohadi M.A.M.; Yee J.; Hanapiah F.A.
title Advancements in Spasticity Management: A Design Framework with PID Integration for Upper Limb Spasticity Training Device (ULSTraD)
title_short Advancements in Spasticity Management: A Design Framework with PID Integration for Upper Limb Spasticity Training Device (ULSTraD)
title_full Advancements in Spasticity Management: A Design Framework with PID Integration for Upper Limb Spasticity Training Device (ULSTraD)
title_fullStr Advancements in Spasticity Management: A Design Framework with PID Integration for Upper Limb Spasticity Training Device (ULSTraD)
title_full_unstemmed Advancements in Spasticity Management: A Design Framework with PID Integration for Upper Limb Spasticity Training Device (ULSTraD)
title_sort Advancements in Spasticity Management: A Design Framework with PID Integration for Upper Limb Spasticity Training Device (ULSTraD)
publishDate 2024
container_title 2024 2nd International Conference on Mechatronics, Control and Robotics, ICMCR 2024
container_volume
container_issue
doi_str_mv 10.1109/ICMCR60777.2024.10481838
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85190514108&doi=10.1109%2fICMCR60777.2024.10481838&partnerID=40&md5=34d36a9bcf9f342fbef96dd26bdd333e
description The upper limb spasticity training device (ULSTraD) is a simulator designed to replicate various spasticity behaviors observed in patients with upper limb spasticity. Through a systematic development process involving requirements analysis, clinical data collection, conceptual design, prototyping, and integration of a Proportional-Integral-Derivative (PID) controller, the ULSTraD achieves precise control over servo motors. The PID controller, in conjunction with the PWM Controller PCA9885 and real-time feedback from the MPU6050 angle sensor, enables accurate spasticity behavior emulation. Optimal PID gains (Kp = 0.9, Ki = 1.0, and Kd = 0.00) were determined through tuning, resulting in the desired target position. By incorporating FSR 460 and conducting tests at various angles using the PID controller, ULSTraD displayed real-time responsiveness to external forces, enhancing its stability and accurately emulating upper limb spasticity behaviors. Guided by anthropometric measurements and clinical data, the ULSTraD closely resembles a real human arm affected by spasticity. The prototyping process involved 3D printing, welding, and assembly, leading to a functional prototype refined through iterative testing. To assess the similarity in range of motion (ROM) between ULSTraD and the human arm, a Paired Sample T-test was conducted, comparing the flexion and extension movements. The obtained p-value from the test was 0.9087, which indicates that there is no statistically significant difference in ROM between ULSTraD and the human arm during both flexion and extension movements. This validates ULSTraD's ability to replicate the human arm's range of motion affected by spasticity. © 2024 IEEE.
publisher Institute of Electrical and Electronics Engineers Inc.
issn
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1809677884875341824