Development of iridium oxide sensor for surface pH measurement of a corroding metal under deposit
A novel method used to design and fabricate a pH sensor for measurement of hydrogen ion activity on corroding metal surface in under deposit. The electrodeposition method of cyclic voltammetry approach is used for coating of Iridium Oxide (IrOX) on stainless steel substrate. The pH value of the X52...