AXIAL DEFORMATION OF SPINE BIO-TENSEGRITY MODEL AT DIFFERENT DEPLOYABLE SCHEMES

The study presents the axial deformation of a spine bio-tensegrity model through a shape change strategy with different deployment schemes. The spine biotensegrity model mimics a human spine's total height, tapered form and natural curvature. Three deployable schemes S1-S3 with a different comb...

Full description

Bibliographic Details
Published in:JURNAL TEKNOLOGI-SCIENCES & ENGINEERING
Main Authors: Rosli, Nur Hazira; Yahya, Syed Muhammad Syed; Wee, Lee Siong; Nishimura, Toku; Lian, Oh Chai
Format: Article
Language:English
Published: PENERBIT UTM PRESS 2024
Subjects:
Online Access:https://www-webofscience-com.uitm.idm.oclc.org/wos/woscc/full-record/WOS:001342155400006
author Rosli
Nur Hazira; Yahya
Syed Muhammad Syed; Wee
Lee Siong; Nishimura
Toku; Lian
Oh Chai
spellingShingle Rosli
Nur Hazira; Yahya
Syed Muhammad Syed; Wee
Lee Siong; Nishimura
Toku; Lian
Oh Chai
AXIAL DEFORMATION OF SPINE BIO-TENSEGRITY MODEL AT DIFFERENT DEPLOYABLE SCHEMES
Engineering
author_facet Rosli
Nur Hazira; Yahya
Syed Muhammad Syed; Wee
Lee Siong; Nishimura
Toku; Lian
Oh Chai
author_sort Rosli
spelling Rosli, Nur Hazira; Yahya, Syed Muhammad Syed; Wee, Lee Siong; Nishimura, Toku; Lian, Oh Chai
AXIAL DEFORMATION OF SPINE BIO-TENSEGRITY MODEL AT DIFFERENT DEPLOYABLE SCHEMES
JURNAL TEKNOLOGI-SCIENCES & ENGINEERING
English
Article
The study presents the axial deformation of a spine bio-tensegrity model through a shape change strategy with different deployment schemes. The spine biotensegrity model mimics a human spine's total height, tapered form and natural curvature. Three deployable schemes S1-S3 with a different combination of cables at alterable and fixed lengths were investigated to achieve a series of axial displacements at 200 mm, 400 mm and 600 mm in the z-direction. The shape change algorithm was developed to optimise the forced elongation of cables, incorporating an objective function designed for monitored nodes in the system to reach their prescribed targets during the optimisation process. Sequential quadratic programming was employed to solve a nonlinear analysis. The efficiency of the deployable systems was assessed based on the deformed shapes, convergence curve, and axial forces of the spine biotensegrity model. The finding shows that in addition to axial deformation, the model S1 deployment scheme preserves the slenderness characteristic of the spine. In contrast, the model exhibits excessive expansion in the thoracic region in schemes S2 and S3. Greater total computational steps in deployment scheme S3, followed by S2 and S1, reveal that the active cables set near the monitored nodes allow the model to sense and act faster to reach their targets. The study contributes to understanding the structural behavior and deployment strategy for a structure mimicking a biological system and it can be extended to applications such as deployable structures and biomechanical studies.
PENERBIT UTM PRESS
0127-9696
2180-3722
2024
86
6
10.11113/jurnalteknologi.v86.21028
Engineering
gold
WOS:001342155400006
https://www-webofscience-com.uitm.idm.oclc.org/wos/woscc/full-record/WOS:001342155400006
title AXIAL DEFORMATION OF SPINE BIO-TENSEGRITY MODEL AT DIFFERENT DEPLOYABLE SCHEMES
title_short AXIAL DEFORMATION OF SPINE BIO-TENSEGRITY MODEL AT DIFFERENT DEPLOYABLE SCHEMES
title_full AXIAL DEFORMATION OF SPINE BIO-TENSEGRITY MODEL AT DIFFERENT DEPLOYABLE SCHEMES
title_fullStr AXIAL DEFORMATION OF SPINE BIO-TENSEGRITY MODEL AT DIFFERENT DEPLOYABLE SCHEMES
title_full_unstemmed AXIAL DEFORMATION OF SPINE BIO-TENSEGRITY MODEL AT DIFFERENT DEPLOYABLE SCHEMES
title_sort AXIAL DEFORMATION OF SPINE BIO-TENSEGRITY MODEL AT DIFFERENT DEPLOYABLE SCHEMES
container_title JURNAL TEKNOLOGI-SCIENCES & ENGINEERING
language English
format Article
description The study presents the axial deformation of a spine bio-tensegrity model through a shape change strategy with different deployment schemes. The spine biotensegrity model mimics a human spine's total height, tapered form and natural curvature. Three deployable schemes S1-S3 with a different combination of cables at alterable and fixed lengths were investigated to achieve a series of axial displacements at 200 mm, 400 mm and 600 mm in the z-direction. The shape change algorithm was developed to optimise the forced elongation of cables, incorporating an objective function designed for monitored nodes in the system to reach their prescribed targets during the optimisation process. Sequential quadratic programming was employed to solve a nonlinear analysis. The efficiency of the deployable systems was assessed based on the deformed shapes, convergence curve, and axial forces of the spine biotensegrity model. The finding shows that in addition to axial deformation, the model S1 deployment scheme preserves the slenderness characteristic of the spine. In contrast, the model exhibits excessive expansion in the thoracic region in schemes S2 and S3. Greater total computational steps in deployment scheme S3, followed by S2 and S1, reveal that the active cables set near the monitored nodes allow the model to sense and act faster to reach their targets. The study contributes to understanding the structural behavior and deployment strategy for a structure mimicking a biological system and it can be extended to applications such as deployable structures and biomechanical studies.
publisher PENERBIT UTM PRESS
issn 0127-9696
2180-3722
publishDate 2024
container_volume 86
container_issue 6
doi_str_mv 10.11113/jurnalteknologi.v86.21028
topic Engineering
topic_facet Engineering
accesstype gold
id WOS:001342155400006
url https://www-webofscience-com.uitm.idm.oclc.org/wos/woscc/full-record/WOS:001342155400006
record_format wos
collection Web of Science (WoS)
_version_ 1818940498682839040