Real-time power quality measurement audit of government building - A case study in compliance with IEEE 1159
Power Quality (PQ) measurements and auditing play a vital role for smart grid applications, industrial safety and reliability. The major Flicker, and Supply Interruptions, are studied with the aim of maintaining the international or national standards. The electrical characteristics are studied and...
Published in: | ACTA IMEKO |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Published: |
IMEKO - Int Measurement Confederation
2023
|
Subjects: | |
Online Access: | https://www-webofscience-com.uitm.idm.oclc.org/wos/woscc/full-record/WOS:001280123200001 |
author |
Ananth D. V. N.; Hannoon Naeem; Yunus Mohamed Shahriman Bin Mohamed; Jamaludin Mohd Hanif Bin; Charavarthy V. V. S. S. Sameer; Chowdary, P. S. R. |
---|---|
spellingShingle |
Ananth D. V. N.; Hannoon Naeem; Yunus Mohamed Shahriman Bin Mohamed; Jamaludin Mohd Hanif Bin; Charavarthy V. V. S. S. Sameer; Chowdary, P. S. R. Real-time power quality measurement audit of government building - A case study in compliance with IEEE 1159 Instruments & Instrumentation |
author_facet |
Ananth D. V. N.; Hannoon Naeem; Yunus Mohamed Shahriman Bin Mohamed; Jamaludin Mohd Hanif Bin; Charavarthy V. V. S. S. Sameer; Chowdary, P. S. R. |
author_sort |
Ananth |
spelling |
Ananth, D. V. N.; Hannoon, Naeem; Yunus, Mohamed Shahriman Bin Mohamed; Jamaludin, Mohd Hanif Bin; Charavarthy, V. V. S. S. Sameer; Chowdary, P. S. R. Real-time power quality measurement audit of government building - A case study in compliance with IEEE 1159 ACTA IMEKO English Article Power Quality (PQ) measurements and auditing play a vital role for smart grid applications, industrial safety and reliability. The major Flicker, and Supply Interruptions, are studied with the aim of maintaining the international or national standards. The electrical characteristics are studied and analyzed for single-phase and poly-phase systems in this IEEE 1159 recommended practice. The significant PQ constraints and parameters, like electromagnetic interference phenomenon deviation from the regular operation due to load equipment or source to load interaction, are described. Further, it is discussed PQ different monitoring devices, roles, and applications. In this paper, power quality monitoring of the equipment using FLUKE instrument and accessories to identify the equipment performance, audit, PQ issues are discussed practically for a two-panel boards switchgear equipment as a case study in Malaysia. Here, trends in voltage and current changes with current imbalances were observed on 1st May 2019 morning 8'o clock and on 7th May 2019 evening at 9'0 clock. IMEKO - Int Measurement Confederation 0237-028X 2221-870X 2023 12 1 Instruments & Instrumentation WOS:001280123200001 https://www-webofscience-com.uitm.idm.oclc.org/wos/woscc/full-record/WOS:001280123200001 |
title |
Real-time power quality measurement audit of government building - A case study in compliance with IEEE 1159 |
title_short |
Real-time power quality measurement audit of government building - A case study in compliance with IEEE 1159 |
title_full |
Real-time power quality measurement audit of government building - A case study in compliance with IEEE 1159 |
title_fullStr |
Real-time power quality measurement audit of government building - A case study in compliance with IEEE 1159 |
title_full_unstemmed |
Real-time power quality measurement audit of government building - A case study in compliance with IEEE 1159 |
title_sort |
Real-time power quality measurement audit of government building - A case study in compliance with IEEE 1159 |
container_title |
ACTA IMEKO |
language |
English |
format |
Article |
description |
Power Quality (PQ) measurements and auditing play a vital role for smart grid applications, industrial safety and reliability. The major Flicker, and Supply Interruptions, are studied with the aim of maintaining the international or national standards. The electrical characteristics are studied and analyzed for single-phase and poly-phase systems in this IEEE 1159 recommended practice. The significant PQ constraints and parameters, like electromagnetic interference phenomenon deviation from the regular operation due to load equipment or source to load interaction, are described. Further, it is discussed PQ different monitoring devices, roles, and applications. In this paper, power quality monitoring of the equipment using FLUKE instrument and accessories to identify the equipment performance, audit, PQ issues are discussed practically for a two-panel boards switchgear equipment as a case study in Malaysia. Here, trends in voltage and current changes with current imbalances were observed on 1st May 2019 morning 8'o clock and on 7th May 2019 evening at 9'0 clock. |
publisher |
IMEKO - Int Measurement Confederation |
issn |
0237-028X 2221-870X |
publishDate |
2023 |
container_volume |
12 |
container_issue |
1 |
doi_str_mv |
|
topic |
Instruments & Instrumentation |
topic_facet |
Instruments & Instrumentation |
accesstype |
|
id |
WOS:001280123200001 |
url |
https://www-webofscience-com.uitm.idm.oclc.org/wos/woscc/full-record/WOS:001280123200001 |
record_format |
wos |
collection |
Web of Science (WoS) |
_version_ |
1809679296927629312 |