Real-time power quality measurement audit of government building - A case study in compliance with IEEE 1159

Power Quality (PQ) measurements and auditing play a vital role for smart grid applications, industrial safety and reliability. The major Flicker, and Supply Interruptions, are studied with the aim of maintaining the international or national standards. The electrical characteristics are studied and...

Full description

Bibliographic Details
Published in:ACTA IMEKO
Main Authors: Ananth, D. V. N.; Hannoon, Naeem; Yunus, Mohamed Shahriman Bin Mohamed; Jamaludin, Mohd Hanif Bin; Charavarthy, V. V. S. S. Sameer; Chowdary, P. S. R.
Format: Article
Language:English
Published: IMEKO - Int Measurement Confederation 2023
Subjects:
Online Access:https://www-webofscience-com.uitm.idm.oclc.org/wos/woscc/full-record/WOS:001280123200001
author Ananth
D. V. N.; Hannoon
Naeem; Yunus
Mohamed Shahriman Bin Mohamed; Jamaludin
Mohd Hanif Bin; Charavarthy
V. V. S. S. Sameer; Chowdary, P. S. R.
spellingShingle Ananth
D. V. N.; Hannoon
Naeem; Yunus
Mohamed Shahriman Bin Mohamed; Jamaludin
Mohd Hanif Bin; Charavarthy
V. V. S. S. Sameer; Chowdary, P. S. R.
Real-time power quality measurement audit of government building - A case study in compliance with IEEE 1159
Instruments & Instrumentation
author_facet Ananth
D. V. N.; Hannoon
Naeem; Yunus
Mohamed Shahriman Bin Mohamed; Jamaludin
Mohd Hanif Bin; Charavarthy
V. V. S. S. Sameer; Chowdary, P. S. R.
author_sort Ananth
spelling Ananth, D. V. N.; Hannoon, Naeem; Yunus, Mohamed Shahriman Bin Mohamed; Jamaludin, Mohd Hanif Bin; Charavarthy, V. V. S. S. Sameer; Chowdary, P. S. R.
Real-time power quality measurement audit of government building - A case study in compliance with IEEE 1159
ACTA IMEKO
English
Article
Power Quality (PQ) measurements and auditing play a vital role for smart grid applications, industrial safety and reliability. The major Flicker, and Supply Interruptions, are studied with the aim of maintaining the international or national standards. The electrical characteristics are studied and analyzed for single-phase and poly-phase systems in this IEEE 1159 recommended practice. The significant PQ constraints and parameters, like electromagnetic interference phenomenon deviation from the regular operation due to load equipment or source to load interaction, are described. Further, it is discussed PQ different monitoring devices, roles, and applications. In this paper, power quality monitoring of the equipment using FLUKE instrument and accessories to identify the equipment performance, audit, PQ issues are discussed practically for a two-panel boards switchgear equipment as a case study in Malaysia. Here, trends in voltage and current changes with current imbalances were observed on 1st May 2019 morning 8'o clock and on 7th May 2019 evening at 9'0 clock.
IMEKO - Int Measurement Confederation
0237-028X
2221-870X
2023
12
1

Instruments & Instrumentation

WOS:001280123200001
https://www-webofscience-com.uitm.idm.oclc.org/wos/woscc/full-record/WOS:001280123200001
title Real-time power quality measurement audit of government building - A case study in compliance with IEEE 1159
title_short Real-time power quality measurement audit of government building - A case study in compliance with IEEE 1159
title_full Real-time power quality measurement audit of government building - A case study in compliance with IEEE 1159
title_fullStr Real-time power quality measurement audit of government building - A case study in compliance with IEEE 1159
title_full_unstemmed Real-time power quality measurement audit of government building - A case study in compliance with IEEE 1159
title_sort Real-time power quality measurement audit of government building - A case study in compliance with IEEE 1159
container_title ACTA IMEKO
language English
format Article
description Power Quality (PQ) measurements and auditing play a vital role for smart grid applications, industrial safety and reliability. The major Flicker, and Supply Interruptions, are studied with the aim of maintaining the international or national standards. The electrical characteristics are studied and analyzed for single-phase and poly-phase systems in this IEEE 1159 recommended practice. The significant PQ constraints and parameters, like electromagnetic interference phenomenon deviation from the regular operation due to load equipment or source to load interaction, are described. Further, it is discussed PQ different monitoring devices, roles, and applications. In this paper, power quality monitoring of the equipment using FLUKE instrument and accessories to identify the equipment performance, audit, PQ issues are discussed practically for a two-panel boards switchgear equipment as a case study in Malaysia. Here, trends in voltage and current changes with current imbalances were observed on 1st May 2019 morning 8'o clock and on 7th May 2019 evening at 9'0 clock.
publisher IMEKO - Int Measurement Confederation
issn 0237-028X
2221-870X
publishDate 2023
container_volume 12
container_issue 1
doi_str_mv
topic Instruments & Instrumentation
topic_facet Instruments & Instrumentation
accesstype
id WOS:001280123200001
url https://www-webofscience-com.uitm.idm.oclc.org/wos/woscc/full-record/WOS:001280123200001
record_format wos
collection Web of Science (WoS)
_version_ 1809679296927629312