OPERATIONAL COST MODELS FOR AN EARTH STATION SYSTEM USING 2-PARALLEL AND 4- PARALLEL CONFIGURATIONS

Operational cost is important in any system. In the case of the earth station system, operational cost is very crucial. The operational cost can be divided into three costs: maintenance, failure, and replacement costs. There are many complex subsystems incorporated in the earth station system, for i...

Full description

Bibliographic Details
Published in:IIUM ENGINEERING JOURNAL
Main Authors: Aris, Wan Muhamad Syaamil w; Rahim, Nadirah Abdul; Mansor, Mahayaudin M.; Rahman, Nur Shazana Abdul
Format: Article
Language:English
Published: KULLIYYAH ENGINEERING 2024
Subjects:
Online Access:https://www-webofscience-com.uitm.idm.oclc.org/wos/woscc/full-record/WOS:001275324200016
author Aris
Wan Muhamad Syaamil w; Rahim
Nadirah Abdul; Mansor
Mahayaudin M.; Rahman
Nur Shazana Abdul
spellingShingle Aris
Wan Muhamad Syaamil w; Rahim
Nadirah Abdul; Mansor
Mahayaudin M.; Rahman
Nur Shazana Abdul
OPERATIONAL COST MODELS FOR AN EARTH STATION SYSTEM USING 2-PARALLEL AND 4- PARALLEL CONFIGURATIONS
Engineering
author_facet Aris
Wan Muhamad Syaamil w; Rahim
Nadirah Abdul; Mansor
Mahayaudin M.; Rahman
Nur Shazana Abdul
author_sort Aris
spelling Aris, Wan Muhamad Syaamil w; Rahim, Nadirah Abdul; Mansor, Mahayaudin M.; Rahman, Nur Shazana Abdul
OPERATIONAL COST MODELS FOR AN EARTH STATION SYSTEM USING 2-PARALLEL AND 4- PARALLEL CONFIGURATIONS
IIUM ENGINEERING JOURNAL
English
Article
Operational cost is important in any system. In the case of the earth station system, operational cost is very crucial. The operational cost can be divided into three costs: maintenance, failure, and replacement costs. There are many complex subsystems incorporated in the earth station system, for instance a high-power amplifier, modulators, and antennas, to name a few. In this research, only the replacement cost was considered. Moreover, there are many replacement methods that are available. These replacement methods implicitly influence both the replacement and the replacement costs. The aim of this research is to provide a new cost model based on which replacement method yields the lowest cost. Two replacement methods are involved in this research: failure-triggered and age-based. The failure-triggered and the age-based replacement methods were considered because these methods are the most used in previous research work. Furthermore, three types of cost models were also considered, and they were linear, polynomial, and exponential operational cost models. The outcomes show that the failure-triggered and age-based replacement methods of 2-parallel configuration of polynomial and linear operational cost models yielded the lowest RMSE value of 2.5. Therefore, both polynomial and linear operational cost models of the 2parallel configuration were the most optimal operational cost models.
KULLIYYAH ENGINEERING
1511-788X
2289-7860
2024
25
2
10.31436/iiumej.v25i2.3063
Engineering
gold
WOS:001275324200016
https://www-webofscience-com.uitm.idm.oclc.org/wos/woscc/full-record/WOS:001275324200016
title OPERATIONAL COST MODELS FOR AN EARTH STATION SYSTEM USING 2-PARALLEL AND 4- PARALLEL CONFIGURATIONS
title_short OPERATIONAL COST MODELS FOR AN EARTH STATION SYSTEM USING 2-PARALLEL AND 4- PARALLEL CONFIGURATIONS
title_full OPERATIONAL COST MODELS FOR AN EARTH STATION SYSTEM USING 2-PARALLEL AND 4- PARALLEL CONFIGURATIONS
title_fullStr OPERATIONAL COST MODELS FOR AN EARTH STATION SYSTEM USING 2-PARALLEL AND 4- PARALLEL CONFIGURATIONS
title_full_unstemmed OPERATIONAL COST MODELS FOR AN EARTH STATION SYSTEM USING 2-PARALLEL AND 4- PARALLEL CONFIGURATIONS
title_sort OPERATIONAL COST MODELS FOR AN EARTH STATION SYSTEM USING 2-PARALLEL AND 4- PARALLEL CONFIGURATIONS
container_title IIUM ENGINEERING JOURNAL
language English
format Article
description Operational cost is important in any system. In the case of the earth station system, operational cost is very crucial. The operational cost can be divided into three costs: maintenance, failure, and replacement costs. There are many complex subsystems incorporated in the earth station system, for instance a high-power amplifier, modulators, and antennas, to name a few. In this research, only the replacement cost was considered. Moreover, there are many replacement methods that are available. These replacement methods implicitly influence both the replacement and the replacement costs. The aim of this research is to provide a new cost model based on which replacement method yields the lowest cost. Two replacement methods are involved in this research: failure-triggered and age-based. The failure-triggered and the age-based replacement methods were considered because these methods are the most used in previous research work. Furthermore, three types of cost models were also considered, and they were linear, polynomial, and exponential operational cost models. The outcomes show that the failure-triggered and age-based replacement methods of 2-parallel configuration of polynomial and linear operational cost models yielded the lowest RMSE value of 2.5. Therefore, both polynomial and linear operational cost models of the 2parallel configuration were the most optimal operational cost models.
publisher KULLIYYAH ENGINEERING
issn 1511-788X
2289-7860
publishDate 2024
container_volume 25
container_issue 2
doi_str_mv 10.31436/iiumej.v25i2.3063
topic Engineering
topic_facet Engineering
accesstype gold
id WOS:001275324200016
url https://www-webofscience-com.uitm.idm.oclc.org/wos/woscc/full-record/WOS:001275324200016
record_format wos
collection Web of Science (WoS)
_version_ 1809679297105887232