Simulation and prediction of residential grid-connected photovoltaic system performance

This paper presents the analysis of the actual, predicted, and simulated technical performance of a residential 2.835 kWp retrofitted grid-connected photovoltaic (GCPV) system under the feed-in-tariff (FiT) scheme in Klang, Malaysia located in the equatorial region. The technical performance indices...

وصف كامل

التفاصيل البيبلوغرافية
الحاوية / القاعدة:International Journal of Power Electronics and Drive Systems
المؤلف الرئيسي: 2-s2.0-85144931177
التنسيق: مقال
اللغة:English
منشور في: Institute of Advanced Engineering and Science 2023
الوصول للمادة أونلاين:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85144931177&doi=10.11591%2fijpeds.v14.i1.pp506-515&partnerID=40&md5=b407e93bf768a415ab7922069afb29c3
id Ibrahim S.N.N.; Zainuddin H.; Rahim Y.I.A.A.; Mansor N.A.; Muhammad N.; Khir F.L.M.
spelling Ibrahim S.N.N.; Zainuddin H.; Rahim Y.I.A.A.; Mansor N.A.; Muhammad N.; Khir F.L.M.
2-s2.0-85144931177
Simulation and prediction of residential grid-connected photovoltaic system performance
2023
International Journal of Power Electronics and Drive Systems
14
1
10.11591/ijpeds.v14.i1.pp506-515
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85144931177&doi=10.11591%2fijpeds.v14.i1.pp506-515&partnerID=40&md5=b407e93bf768a415ab7922069afb29c3
This paper presents the analysis of the actual, predicted, and simulated technical performance of a residential 2.835 kWp retrofitted grid-connected photovoltaic (GCPV) system under the feed-in-tariff (FiT) scheme in Klang, Malaysia located in the equatorial region. The technical performance indices of the GCPV system were assessed based on the three-year energy production in 2018, 2019 and 2020. The actual and predicted technical performance were calculated using SEDA mathematical model, which the solar irradiation data was acquired from PVsyst software. Meanwhile, the simulated technical performance was obtained using PVsyst software. The results showed that the prediction using mathematical model has higher percentage difference within the range of 12.54-13.29%, compared to PVsyst simulation that was within 7.93-11.93%. This study has highlighted the factors that contributed to the technical performance underprediction of both mathematical model and PVsyst simulation, which are the estimation of losses and annual irradiation data accuracy. Lastly, the FiT gross income calculated for the three consecutive years were within the range of 3310.80 MYR and 3357.30 MYR. This FiT gross income result conveys an example of Malaysian case study, to enlighten the public, on the economic aspect of installing GCPV system under FiT scheme. © 2023, Institute of Advanced Engineering and Science. All rights reserved.
Institute of Advanced Engineering and Science
20888694
English
Article
All Open Access; Gold Open Access; Green Open Access
author 2-s2.0-85144931177
spellingShingle 2-s2.0-85144931177
Simulation and prediction of residential grid-connected photovoltaic system performance
author_facet 2-s2.0-85144931177
author_sort 2-s2.0-85144931177
title Simulation and prediction of residential grid-connected photovoltaic system performance
title_short Simulation and prediction of residential grid-connected photovoltaic system performance
title_full Simulation and prediction of residential grid-connected photovoltaic system performance
title_fullStr Simulation and prediction of residential grid-connected photovoltaic system performance
title_full_unstemmed Simulation and prediction of residential grid-connected photovoltaic system performance
title_sort Simulation and prediction of residential grid-connected photovoltaic system performance
publishDate 2023
container_title International Journal of Power Electronics and Drive Systems
container_volume 14
container_issue 1
doi_str_mv 10.11591/ijpeds.v14.i1.pp506-515
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85144931177&doi=10.11591%2fijpeds.v14.i1.pp506-515&partnerID=40&md5=b407e93bf768a415ab7922069afb29c3
description This paper presents the analysis of the actual, predicted, and simulated technical performance of a residential 2.835 kWp retrofitted grid-connected photovoltaic (GCPV) system under the feed-in-tariff (FiT) scheme in Klang, Malaysia located in the equatorial region. The technical performance indices of the GCPV system were assessed based on the three-year energy production in 2018, 2019 and 2020. The actual and predicted technical performance were calculated using SEDA mathematical model, which the solar irradiation data was acquired from PVsyst software. Meanwhile, the simulated technical performance was obtained using PVsyst software. The results showed that the prediction using mathematical model has higher percentage difference within the range of 12.54-13.29%, compared to PVsyst simulation that was within 7.93-11.93%. This study has highlighted the factors that contributed to the technical performance underprediction of both mathematical model and PVsyst simulation, which are the estimation of losses and annual irradiation data accuracy. Lastly, the FiT gross income calculated for the three consecutive years were within the range of 3310.80 MYR and 3357.30 MYR. This FiT gross income result conveys an example of Malaysian case study, to enlighten the public, on the economic aspect of installing GCPV system under FiT scheme. © 2023, Institute of Advanced Engineering and Science. All rights reserved.
publisher Institute of Advanced Engineering and Science
issn 20888694
language English
format Article
accesstype All Open Access; Gold Open Access; Green Open Access
record_format scopus
collection Scopus
_version_ 1828987866414317568