Automatic detection of the end-diastolic and end-systolic from 4D echocardiographic images

Accurate detection of the End-Diastolic (ED) and End-Systolic (ES) frames of a cardiac cycle are significant factors that may affect the accuracy of abnormality assessment of a ventricle. This process is a routine step of the ventricle assessment procedure as most of the time in clinical reports man...

وصف كامل

التفاصيل البيبلوغرافية
الحاوية / القاعدة:Journal of Computer Science
المؤلف الرئيسي: 2-s2.0-84923081929
التنسيق: مقال
اللغة:English
منشور في: Science Publications 2015
الوصول للمادة أونلاين:https://www.scopus.com/inward/record.uri?eid=2-s2.0-84923081929&doi=10.3844%2fjcssp.2015.230.240&partnerID=40&md5=849bbb5668bdfb795d5df69ab82077f1
id Abboud A.A.; Rahmat R.W.; Kadiman S.B.; Dimon M.Z.B.; Nurliyana L.; Saripan M.I.; Khaleel H.H.
spelling Abboud A.A.; Rahmat R.W.; Kadiman S.B.; Dimon M.Z.B.; Nurliyana L.; Saripan M.I.; Khaleel H.H.
2-s2.0-84923081929
Automatic detection of the end-diastolic and end-systolic from 4D echocardiographic images
2015
Journal of Computer Science
11
1
10.3844/jcssp.2015.230.240
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84923081929&doi=10.3844%2fjcssp.2015.230.240&partnerID=40&md5=849bbb5668bdfb795d5df69ab82077f1
Accurate detection of the End-Diastolic (ED) and End-Systolic (ES) frames of a cardiac cycle are significant factors that may affect the accuracy of abnormality assessment of a ventricle. This process is a routine step of the ventricle assessment procedure as most of the time in clinical reports many parameters are measured in these two frames to help in diagnosing and dissection making. According to the previous works the process of detecting the ED and ES remains a challenge in that the ED and ES frames for the cavity are usually determined manually by review of individual image phases of the cavity and/or tracking the tricuspid valve. The proposed algorithm aims to automatically determine the ED and ES frames from the four Dimensional Echocardiographic images (4DE) of the Right Ventricle (RV) from one cardiac cycle. By computing the area of three slices along one cardiac cycle and selecting the maximum area as the ED frame and the minimum area as the ES frame. This method gives an accurate determination for the ED and ES frames, hence avoid the need for time consuming, expert contributions during the process of computing the cavity stroke volume. © 2015 The Anas A. Abboud, Rahmita Wirza Rahmat, Suhaini Bin Kadiman, Mohd Zamrin Bin Dimon, Lili Nurliyana, M. Iqbal Saripan and Hasan H. Khaleel.
Science Publications
15493636
English
Article
All Open Access; Green Open Access; Hybrid Gold Open Access
author 2-s2.0-84923081929
spellingShingle 2-s2.0-84923081929
Automatic detection of the end-diastolic and end-systolic from 4D echocardiographic images
author_facet 2-s2.0-84923081929
author_sort 2-s2.0-84923081929
title Automatic detection of the end-diastolic and end-systolic from 4D echocardiographic images
title_short Automatic detection of the end-diastolic and end-systolic from 4D echocardiographic images
title_full Automatic detection of the end-diastolic and end-systolic from 4D echocardiographic images
title_fullStr Automatic detection of the end-diastolic and end-systolic from 4D echocardiographic images
title_full_unstemmed Automatic detection of the end-diastolic and end-systolic from 4D echocardiographic images
title_sort Automatic detection of the end-diastolic and end-systolic from 4D echocardiographic images
publishDate 2015
container_title Journal of Computer Science
container_volume 11
container_issue 1
doi_str_mv 10.3844/jcssp.2015.230.240
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-84923081929&doi=10.3844%2fjcssp.2015.230.240&partnerID=40&md5=849bbb5668bdfb795d5df69ab82077f1
description Accurate detection of the End-Diastolic (ED) and End-Systolic (ES) frames of a cardiac cycle are significant factors that may affect the accuracy of abnormality assessment of a ventricle. This process is a routine step of the ventricle assessment procedure as most of the time in clinical reports many parameters are measured in these two frames to help in diagnosing and dissection making. According to the previous works the process of detecting the ED and ES remains a challenge in that the ED and ES frames for the cavity are usually determined manually by review of individual image phases of the cavity and/or tracking the tricuspid valve. The proposed algorithm aims to automatically determine the ED and ES frames from the four Dimensional Echocardiographic images (4DE) of the Right Ventricle (RV) from one cardiac cycle. By computing the area of three slices along one cardiac cycle and selecting the maximum area as the ED frame and the minimum area as the ES frame. This method gives an accurate determination for the ED and ES frames, hence avoid the need for time consuming, expert contributions during the process of computing the cavity stroke volume. © 2015 The Anas A. Abboud, Rahmita Wirza Rahmat, Suhaini Bin Kadiman, Mohd Zamrin Bin Dimon, Lili Nurliyana, M. Iqbal Saripan and Hasan H. Khaleel.
publisher Science Publications
issn 15493636
language English
format Article
accesstype All Open Access; Green Open Access; Hybrid Gold Open Access
record_format scopus
collection Scopus
_version_ 1828987882456481792