Automatic detection of the end-diastolic and end-systolic from 4D echocardiographic images
Accurate detection of the End-Diastolic (ED) and End-Systolic (ES) frames of a cardiac cycle are significant factors that may affect the accuracy of abnormality assessment of a ventricle. This process is a routine step of the ventricle assessment procedure as most of the time in clinical reports man...
الحاوية / القاعدة: | Journal of Computer Science |
---|---|
المؤلف الرئيسي: | |
التنسيق: | مقال |
اللغة: | English |
منشور في: |
Science Publications
2015
|
الوصول للمادة أونلاين: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84923081929&doi=10.3844%2fjcssp.2015.230.240&partnerID=40&md5=849bbb5668bdfb795d5df69ab82077f1 |
id |
Abboud A.A.; Rahmat R.W.; Kadiman S.B.; Dimon M.Z.B.; Nurliyana L.; Saripan M.I.; Khaleel H.H. |
---|---|
spelling |
Abboud A.A.; Rahmat R.W.; Kadiman S.B.; Dimon M.Z.B.; Nurliyana L.; Saripan M.I.; Khaleel H.H. 2-s2.0-84923081929 Automatic detection of the end-diastolic and end-systolic from 4D echocardiographic images 2015 Journal of Computer Science 11 1 10.3844/jcssp.2015.230.240 https://www.scopus.com/inward/record.uri?eid=2-s2.0-84923081929&doi=10.3844%2fjcssp.2015.230.240&partnerID=40&md5=849bbb5668bdfb795d5df69ab82077f1 Accurate detection of the End-Diastolic (ED) and End-Systolic (ES) frames of a cardiac cycle are significant factors that may affect the accuracy of abnormality assessment of a ventricle. This process is a routine step of the ventricle assessment procedure as most of the time in clinical reports many parameters are measured in these two frames to help in diagnosing and dissection making. According to the previous works the process of detecting the ED and ES remains a challenge in that the ED and ES frames for the cavity are usually determined manually by review of individual image phases of the cavity and/or tracking the tricuspid valve. The proposed algorithm aims to automatically determine the ED and ES frames from the four Dimensional Echocardiographic images (4DE) of the Right Ventricle (RV) from one cardiac cycle. By computing the area of three slices along one cardiac cycle and selecting the maximum area as the ED frame and the minimum area as the ES frame. This method gives an accurate determination for the ED and ES frames, hence avoid the need for time consuming, expert contributions during the process of computing the cavity stroke volume. © 2015 The Anas A. Abboud, Rahmita Wirza Rahmat, Suhaini Bin Kadiman, Mohd Zamrin Bin Dimon, Lili Nurliyana, M. Iqbal Saripan and Hasan H. Khaleel. Science Publications 15493636 English Article All Open Access; Green Open Access; Hybrid Gold Open Access |
author |
2-s2.0-84923081929 |
spellingShingle |
2-s2.0-84923081929 Automatic detection of the end-diastolic and end-systolic from 4D echocardiographic images |
author_facet |
2-s2.0-84923081929 |
author_sort |
2-s2.0-84923081929 |
title |
Automatic detection of the end-diastolic and end-systolic from 4D echocardiographic images |
title_short |
Automatic detection of the end-diastolic and end-systolic from 4D echocardiographic images |
title_full |
Automatic detection of the end-diastolic and end-systolic from 4D echocardiographic images |
title_fullStr |
Automatic detection of the end-diastolic and end-systolic from 4D echocardiographic images |
title_full_unstemmed |
Automatic detection of the end-diastolic and end-systolic from 4D echocardiographic images |
title_sort |
Automatic detection of the end-diastolic and end-systolic from 4D echocardiographic images |
publishDate |
2015 |
container_title |
Journal of Computer Science |
container_volume |
11 |
container_issue |
1 |
doi_str_mv |
10.3844/jcssp.2015.230.240 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84923081929&doi=10.3844%2fjcssp.2015.230.240&partnerID=40&md5=849bbb5668bdfb795d5df69ab82077f1 |
description |
Accurate detection of the End-Diastolic (ED) and End-Systolic (ES) frames of a cardiac cycle are significant factors that may affect the accuracy of abnormality assessment of a ventricle. This process is a routine step of the ventricle assessment procedure as most of the time in clinical reports many parameters are measured in these two frames to help in diagnosing and dissection making. According to the previous works the process of detecting the ED and ES remains a challenge in that the ED and ES frames for the cavity are usually determined manually by review of individual image phases of the cavity and/or tracking the tricuspid valve. The proposed algorithm aims to automatically determine the ED and ES frames from the four Dimensional Echocardiographic images (4DE) of the Right Ventricle (RV) from one cardiac cycle. By computing the area of three slices along one cardiac cycle and selecting the maximum area as the ED frame and the minimum area as the ES frame. This method gives an accurate determination for the ED and ES frames, hence avoid the need for time consuming, expert contributions during the process of computing the cavity stroke volume. © 2015 The Anas A. Abboud, Rahmita Wirza Rahmat, Suhaini Bin Kadiman, Mohd Zamrin Bin Dimon, Lili Nurliyana, M. Iqbal Saripan and Hasan H. Khaleel. |
publisher |
Science Publications |
issn |
15493636 |
language |
English |
format |
Article |
accesstype |
All Open Access; Green Open Access; Hybrid Gold Open Access |
record_format |
scopus |
collection |
Scopus |
_version_ |
1828987882456481792 |