Influence of Column Length on Settlement Performance of Floating Stone Column in Soft Clay
This paper presents the experimental solutions for the influence of length to the behavior and settlement performance of stone column. Laboratory experiments were conducted to compare the results between the settlement performance of end bearing stone columns and floating stone columns. Unit cell co...
Published in: | Journal of Advanced Research in Applied Mechanics |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Published: |
Semarak Ilmu Publishing
2025
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85217494047&doi=10.37934%2faram.132.1.6069&partnerID=40&md5=8f823b4b663f0dca88bc7929158ffc3f |
id |
2-s2.0-85217494047 |
---|---|
spelling |
2-s2.0-85217494047 Azmi Y.I.; Nik Omar N.A.H.; Ng K.S.; Rashid A.S.A.; Mukri M.; Chew Y.M. Influence of Column Length on Settlement Performance of Floating Stone Column in Soft Clay 2025 Journal of Advanced Research in Applied Mechanics 132 1 10.37934/aram.132.1.6069 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85217494047&doi=10.37934%2faram.132.1.6069&partnerID=40&md5=8f823b4b663f0dca88bc7929158ffc3f This paper presents the experimental solutions for the influence of length to the behavior and settlement performance of stone column. Laboratory experiments were conducted to compare the results between the settlement performance of end bearing stone columns and floating stone columns. Unit cell concept is used to idealize the settlement performance of large column group under the uniform load. The parameters that investigated are the column length to diameter ratio. This experimental investigation used a small-scale unit cell model tank and investigated the column length of a single column. Furthermore, the physical test involved the use of a custom-made stone column model, constructed with a rectangular steel frame measuring 600 mm in height and 260*260 mm in length and width. The experiment incorporated three different column heights: 400 mm, 320 mm, and 240 mm. Additionally, three distinct area replacement ratios of 33%, 23% and 15% were employed in these testing experiments. The results indicated that an increase in the length of stone columns correlates with a reduction in settlement, together with the increase ability to dissipate excess water pressure leading to a faster consolidation rate. The settlement performance was compared with existing analytical solution where reasonable agreement was obtained. © 2025, Semarak Ilmu Publishing. All rights reserved. Semarak Ilmu Publishing 22897895 English Article All Open Access; Gold Open Access |
author |
Azmi Y.I.; Nik Omar N.A.H.; Ng K.S.; Rashid A.S.A.; Mukri M.; Chew Y.M. |
spellingShingle |
Azmi Y.I.; Nik Omar N.A.H.; Ng K.S.; Rashid A.S.A.; Mukri M.; Chew Y.M. Influence of Column Length on Settlement Performance of Floating Stone Column in Soft Clay |
author_facet |
Azmi Y.I.; Nik Omar N.A.H.; Ng K.S.; Rashid A.S.A.; Mukri M.; Chew Y.M. |
author_sort |
Azmi Y.I.; Nik Omar N.A.H.; Ng K.S.; Rashid A.S.A.; Mukri M.; Chew Y.M. |
title |
Influence of Column Length on Settlement Performance of Floating Stone Column in Soft Clay |
title_short |
Influence of Column Length on Settlement Performance of Floating Stone Column in Soft Clay |
title_full |
Influence of Column Length on Settlement Performance of Floating Stone Column in Soft Clay |
title_fullStr |
Influence of Column Length on Settlement Performance of Floating Stone Column in Soft Clay |
title_full_unstemmed |
Influence of Column Length on Settlement Performance of Floating Stone Column in Soft Clay |
title_sort |
Influence of Column Length on Settlement Performance of Floating Stone Column in Soft Clay |
publishDate |
2025 |
container_title |
Journal of Advanced Research in Applied Mechanics |
container_volume |
132 |
container_issue |
1 |
doi_str_mv |
10.37934/aram.132.1.6069 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85217494047&doi=10.37934%2faram.132.1.6069&partnerID=40&md5=8f823b4b663f0dca88bc7929158ffc3f |
description |
This paper presents the experimental solutions for the influence of length to the behavior and settlement performance of stone column. Laboratory experiments were conducted to compare the results between the settlement performance of end bearing stone columns and floating stone columns. Unit cell concept is used to idealize the settlement performance of large column group under the uniform load. The parameters that investigated are the column length to diameter ratio. This experimental investigation used a small-scale unit cell model tank and investigated the column length of a single column. Furthermore, the physical test involved the use of a custom-made stone column model, constructed with a rectangular steel frame measuring 600 mm in height and 260*260 mm in length and width. The experiment incorporated three different column heights: 400 mm, 320 mm, and 240 mm. Additionally, three distinct area replacement ratios of 33%, 23% and 15% were employed in these testing experiments. The results indicated that an increase in the length of stone columns correlates with a reduction in settlement, together with the increase ability to dissipate excess water pressure leading to a faster consolidation rate. The settlement performance was compared with existing analytical solution where reasonable agreement was obtained. © 2025, Semarak Ilmu Publishing. All rights reserved. |
publisher |