Machine Parameters Estimation Using Closed-Loop Control Signal Curve Fitting

Apart from the current limits, the voltage limits will also affect the achievable performance of a motor drive. The voltage limits for a fault-tolerant drive will decide the maximum operating speed of the machine before flux weakening, hence the maximum attainable output power. Unlike current limits...

Full description

Bibliographic Details
Published in:IEACon 2024 - 2024 IEEE Industrial Electronics and Applications Conference
Main Author: Wan Abdul Munim W.N.; Che H.S.; Tousizadeh M.; Baharom R.; Muhammad K.S.; Abdul Rahman N.F.
Format: Conference paper
Language:English
Published: Institute of Electrical and Electronics Engineers Inc. 2024
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85216531767&doi=10.1109%2fIEACon61321.2024.10797442&partnerID=40&md5=9bf87c06e7950a507e791b50cbb5043c
id 2-s2.0-85216531767
spelling 2-s2.0-85216531767
Wan Abdul Munim W.N.; Che H.S.; Tousizadeh M.; Baharom R.; Muhammad K.S.; Abdul Rahman N.F.
Machine Parameters Estimation Using Closed-Loop Control Signal Curve Fitting
2024
IEACon 2024 - 2024 IEEE Industrial Electronics and Applications Conference


10.1109/IEACon61321.2024.10797442
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85216531767&doi=10.1109%2fIEACon61321.2024.10797442&partnerID=40&md5=9bf87c06e7950a507e791b50cbb5043c
Apart from the current limits, the voltage limits will also affect the achievable performance of a motor drive. The voltage limits for a fault-tolerant drive will decide the maximum operating speed of the machine before flux weakening, hence the maximum attainable output power. Unlike current limits, the voltage limits of the fault-tolerant drive depend on the machine parameters. Hence, an accurate machine parameter needs to be obtained to estimate the voltage variations under different fault scenarios. By using the measured currents and plugging it into the machine voltage equations, the theoretical voltages for the machine can be calculated using some initial values for the machine parameters. Accurate machine parameters can be obtained by optimizing the machine parameters to minimize the theoretical voltage and the actual control voltages. It is shown that the estimated machine parameters are accurate enough to predict the control voltage references under varying operating conditions. © 2024 IEEE.
Institute of Electrical and Electronics Engineers Inc.

English
Conference paper

author Wan Abdul Munim W.N.; Che H.S.; Tousizadeh M.; Baharom R.; Muhammad K.S.; Abdul Rahman N.F.
spellingShingle Wan Abdul Munim W.N.; Che H.S.; Tousizadeh M.; Baharom R.; Muhammad K.S.; Abdul Rahman N.F.
Machine Parameters Estimation Using Closed-Loop Control Signal Curve Fitting
author_facet Wan Abdul Munim W.N.; Che H.S.; Tousizadeh M.; Baharom R.; Muhammad K.S.; Abdul Rahman N.F.
author_sort Wan Abdul Munim W.N.; Che H.S.; Tousizadeh M.; Baharom R.; Muhammad K.S.; Abdul Rahman N.F.
title Machine Parameters Estimation Using Closed-Loop Control Signal Curve Fitting
title_short Machine Parameters Estimation Using Closed-Loop Control Signal Curve Fitting
title_full Machine Parameters Estimation Using Closed-Loop Control Signal Curve Fitting
title_fullStr Machine Parameters Estimation Using Closed-Loop Control Signal Curve Fitting
title_full_unstemmed Machine Parameters Estimation Using Closed-Loop Control Signal Curve Fitting
title_sort Machine Parameters Estimation Using Closed-Loop Control Signal Curve Fitting
publishDate 2024
container_title IEACon 2024 - 2024 IEEE Industrial Electronics and Applications Conference
container_volume
container_issue
doi_str_mv 10.1109/IEACon61321.2024.10797442
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85216531767&doi=10.1109%2fIEACon61321.2024.10797442&partnerID=40&md5=9bf87c06e7950a507e791b50cbb5043c
description Apart from the current limits, the voltage limits will also affect the achievable performance of a motor drive. The voltage limits for a fault-tolerant drive will decide the maximum operating speed of the machine before flux weakening, hence the maximum attainable output power. Unlike current limits, the voltage limits of the fault-tolerant drive depend on the machine parameters. Hence, an accurate machine parameter needs to be obtained to estimate the voltage variations under different fault scenarios. By using the measured currents and plugging it into the machine voltage equations, the theoretical voltages for the machine can be calculated using some initial values for the machine parameters. Accurate machine parameters can be obtained by optimizing the machine parameters to minimize the theoretical voltage and the actual control voltages. It is shown that the estimated machine parameters are accurate enough to predict the control voltage references under varying operating conditions. © 2024 IEEE.
publisher Institute of Electrical and Electronics Engineers Inc.
issn
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1825722578572935168