Machine Parameters Estimation Using Closed-Loop Control Signal Curve Fitting
Apart from the current limits, the voltage limits will also affect the achievable performance of a motor drive. The voltage limits for a fault-tolerant drive will decide the maximum operating speed of the machine before flux weakening, hence the maximum attainable output power. Unlike current limits...
Published in: | IEACon 2024 - 2024 IEEE Industrial Electronics and Applications Conference |
---|---|
Main Author: | |
Format: | Conference paper |
Language: | English |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2024
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85216531767&doi=10.1109%2fIEACon61321.2024.10797442&partnerID=40&md5=9bf87c06e7950a507e791b50cbb5043c |
id |
2-s2.0-85216531767 |
---|---|
spelling |
2-s2.0-85216531767 Wan Abdul Munim W.N.; Che H.S.; Tousizadeh M.; Baharom R.; Muhammad K.S.; Abdul Rahman N.F. Machine Parameters Estimation Using Closed-Loop Control Signal Curve Fitting 2024 IEACon 2024 - 2024 IEEE Industrial Electronics and Applications Conference 10.1109/IEACon61321.2024.10797442 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85216531767&doi=10.1109%2fIEACon61321.2024.10797442&partnerID=40&md5=9bf87c06e7950a507e791b50cbb5043c Apart from the current limits, the voltage limits will also affect the achievable performance of a motor drive. The voltage limits for a fault-tolerant drive will decide the maximum operating speed of the machine before flux weakening, hence the maximum attainable output power. Unlike current limits, the voltage limits of the fault-tolerant drive depend on the machine parameters. Hence, an accurate machine parameter needs to be obtained to estimate the voltage variations under different fault scenarios. By using the measured currents and plugging it into the machine voltage equations, the theoretical voltages for the machine can be calculated using some initial values for the machine parameters. Accurate machine parameters can be obtained by optimizing the machine parameters to minimize the theoretical voltage and the actual control voltages. It is shown that the estimated machine parameters are accurate enough to predict the control voltage references under varying operating conditions. © 2024 IEEE. Institute of Electrical and Electronics Engineers Inc. English Conference paper |
author |
Wan Abdul Munim W.N.; Che H.S.; Tousizadeh M.; Baharom R.; Muhammad K.S.; Abdul Rahman N.F. |
spellingShingle |
Wan Abdul Munim W.N.; Che H.S.; Tousizadeh M.; Baharom R.; Muhammad K.S.; Abdul Rahman N.F. Machine Parameters Estimation Using Closed-Loop Control Signal Curve Fitting |
author_facet |
Wan Abdul Munim W.N.; Che H.S.; Tousizadeh M.; Baharom R.; Muhammad K.S.; Abdul Rahman N.F. |
author_sort |
Wan Abdul Munim W.N.; Che H.S.; Tousizadeh M.; Baharom R.; Muhammad K.S.; Abdul Rahman N.F. |
title |
Machine Parameters Estimation Using Closed-Loop Control Signal Curve Fitting |
title_short |
Machine Parameters Estimation Using Closed-Loop Control Signal Curve Fitting |
title_full |
Machine Parameters Estimation Using Closed-Loop Control Signal Curve Fitting |
title_fullStr |
Machine Parameters Estimation Using Closed-Loop Control Signal Curve Fitting |
title_full_unstemmed |
Machine Parameters Estimation Using Closed-Loop Control Signal Curve Fitting |
title_sort |
Machine Parameters Estimation Using Closed-Loop Control Signal Curve Fitting |
publishDate |
2024 |
container_title |
IEACon 2024 - 2024 IEEE Industrial Electronics and Applications Conference |
container_volume |
|
container_issue |
|
doi_str_mv |
10.1109/IEACon61321.2024.10797442 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85216531767&doi=10.1109%2fIEACon61321.2024.10797442&partnerID=40&md5=9bf87c06e7950a507e791b50cbb5043c |
description |
Apart from the current limits, the voltage limits will also affect the achievable performance of a motor drive. The voltage limits for a fault-tolerant drive will decide the maximum operating speed of the machine before flux weakening, hence the maximum attainable output power. Unlike current limits, the voltage limits of the fault-tolerant drive depend on the machine parameters. Hence, an accurate machine parameter needs to be obtained to estimate the voltage variations under different fault scenarios. By using the measured currents and plugging it into the machine voltage equations, the theoretical voltages for the machine can be calculated using some initial values for the machine parameters. Accurate machine parameters can be obtained by optimizing the machine parameters to minimize the theoretical voltage and the actual control voltages. It is shown that the estimated machine parameters are accurate enough to predict the control voltage references under varying operating conditions. © 2024 IEEE. |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
issn |
|
language |
English |
format |
Conference paper |
accesstype |
|
record_format |
scopus |
collection |
Scopus |
_version_ |
1825722578572935168 |