Chlorine Safety in Water Treatment: A Study of Causes and Preventive Measures Through Fault Tree and Event Tree Analysis

Accidents in process industries, especially involving hazardous substances like chlorine, pose significant risks to humans, the environment, and property. This paper examines chlorine-related incidents in water treatment plants (WTPs), where chlorine gas is used for disinfection. Typically, WTPs sto...

Full description

Bibliographic Details
Published in:International Journal of Safety and Security Engineering
Main Author: Zainulabidin S.; Rashid Z.A.; Ahmad M.A.
Format: Article
Language:English
Published: International Information and Engineering Technology Association 2024
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85214088874&doi=10.18280%2fijsse.140614&partnerID=40&md5=61259cc0046c045273a3b0275c2652a7
id 2-s2.0-85214088874
spelling 2-s2.0-85214088874
Zainulabidin S.; Rashid Z.A.; Ahmad M.A.
Chlorine Safety in Water Treatment: A Study of Causes and Preventive Measures Through Fault Tree and Event Tree Analysis
2024
International Journal of Safety and Security Engineering
14
6
10.18280/ijsse.140614
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85214088874&doi=10.18280%2fijsse.140614&partnerID=40&md5=61259cc0046c045273a3b0275c2652a7
Accidents in process industries, especially involving hazardous substances like chlorine, pose significant risks to humans, the environment, and property. This paper examines chlorine-related incidents in water treatment plants (WTPs), where chlorine gas is used for disinfection. Typically, WTPs store over 20 chlorine drums, each containing around 930 kg, increasing inherent risks due to chlorine’s reactivity and health consequences upon exposure. Incidents such as the Bhopal 2022 case, which hospitalized 15 people, and the Kota Belud 2017 case highlight the importance of safe operation. This study aims to identify the root causes of chlorine-related incidents, assess their impacts, and recommend effective preventive measures to enhance safety. Using Fault Tree Analysis (FTA) to identify root causes and Event Tree Analysis (ETA) to evaluate preventive measures. Major failure causes included equipment damage, corrosion, non-compliance with design specifications, and mishandling. Preventive measures like leak detectors, scrubber systems, and Emergency Shutdown Systems (ESD) significantly reduce risks. If scrubbers fail but ESD works with trained personnel, or if scrubbers work but ESD fails without personnel, the impact remains medium. However, chlorine releases become catastrophic when all measures fail or only leak detectors work without effective mitigation systems. ©2024 The authors.
International Information and Engineering Technology Association
20419031
English
Article

author Zainulabidin S.; Rashid Z.A.; Ahmad M.A.
spellingShingle Zainulabidin S.; Rashid Z.A.; Ahmad M.A.
Chlorine Safety in Water Treatment: A Study of Causes and Preventive Measures Through Fault Tree and Event Tree Analysis
author_facet Zainulabidin S.; Rashid Z.A.; Ahmad M.A.
author_sort Zainulabidin S.; Rashid Z.A.; Ahmad M.A.
title Chlorine Safety in Water Treatment: A Study of Causes and Preventive Measures Through Fault Tree and Event Tree Analysis
title_short Chlorine Safety in Water Treatment: A Study of Causes and Preventive Measures Through Fault Tree and Event Tree Analysis
title_full Chlorine Safety in Water Treatment: A Study of Causes and Preventive Measures Through Fault Tree and Event Tree Analysis
title_fullStr Chlorine Safety in Water Treatment: A Study of Causes and Preventive Measures Through Fault Tree and Event Tree Analysis
title_full_unstemmed Chlorine Safety in Water Treatment: A Study of Causes and Preventive Measures Through Fault Tree and Event Tree Analysis
title_sort Chlorine Safety in Water Treatment: A Study of Causes and Preventive Measures Through Fault Tree and Event Tree Analysis
publishDate 2024
container_title International Journal of Safety and Security Engineering
container_volume 14
container_issue 6
doi_str_mv 10.18280/ijsse.140614
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85214088874&doi=10.18280%2fijsse.140614&partnerID=40&md5=61259cc0046c045273a3b0275c2652a7
description Accidents in process industries, especially involving hazardous substances like chlorine, pose significant risks to humans, the environment, and property. This paper examines chlorine-related incidents in water treatment plants (WTPs), where chlorine gas is used for disinfection. Typically, WTPs store over 20 chlorine drums, each containing around 930 kg, increasing inherent risks due to chlorine’s reactivity and health consequences upon exposure. Incidents such as the Bhopal 2022 case, which hospitalized 15 people, and the Kota Belud 2017 case highlight the importance of safe operation. This study aims to identify the root causes of chlorine-related incidents, assess their impacts, and recommend effective preventive measures to enhance safety. Using Fault Tree Analysis (FTA) to identify root causes and Event Tree Analysis (ETA) to evaluate preventive measures. Major failure causes included equipment damage, corrosion, non-compliance with design specifications, and mishandling. Preventive measures like leak detectors, scrubber systems, and Emergency Shutdown Systems (ESD) significantly reduce risks. If scrubbers fail but ESD works with trained personnel, or if scrubbers work but ESD fails without personnel, the impact remains medium. However, chlorine releases become catastrophic when all measures fail or only leak detectors work without effective mitigation systems. ©2024 The authors.
publisher International Information and Engineering Technology Association
issn 20419031
language English
format Article
accesstype
record_format scopus
collection Scopus
_version_ 1823296153467224064