EVALUATING THE IMPACT OF DESIGN FAILURE ON THE PERAK TENGAH DISTRICT MOSQUE, PERAK, MALAYSIA

This study investigates how building structural defects affect maintenance management in mosques in the Perak Tengah District. As well as offering suggestions for improving maintenance effectiveness, it draws attention to the fundamental design defects that cause issues with maintenance. A literatur...

Full description

Bibliographic Details
Published in:Planning Malaysia
Main Author: Khalid M.K.A.; Zawawi Z.A.; Ahmad N.A.; Zahari N.F.; Hashim H.
Format: Article
Language:English
Published: Malaysian Institute Of Planners 2024
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85210931323&doi=10.21837%2fpm.v22i34.1624&partnerID=40&md5=8bb7599f88f83c08a87cc38ec04996ed
id 2-s2.0-85210931323
spelling 2-s2.0-85210931323
Khalid M.K.A.; Zawawi Z.A.; Ahmad N.A.; Zahari N.F.; Hashim H.
EVALUATING THE IMPACT OF DESIGN FAILURE ON THE PERAK TENGAH DISTRICT MOSQUE, PERAK, MALAYSIA
2024
Planning Malaysia
22
6
10.21837/pm.v22i34.1624
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85210931323&doi=10.21837%2fpm.v22i34.1624&partnerID=40&md5=8bb7599f88f83c08a87cc38ec04996ed
This study investigates how building structural defects affect maintenance management in mosques in the Perak Tengah District. As well as offering suggestions for improving maintenance effectiveness, it draws attention to the fundamental design defects that cause issues with maintenance. A literature study, semi-structured interviews, observation, and a survey were used to collect the data. According to the goal of this study, inadequate site supervision, an inadequate cover of reinforcing concrete, poor structural design, noncompliance with specifications, improperly placed or applied paint, and a failure to specify suitable materials are the main design flaws that lead to maintenance issues. These defects result in increased maintenance expenses, job loads, the labour force, and the frequency of maintenance. Based on the study, all departments should collaborate and employ weather-resistant materials to improve job standards and building upkeep. © 2024 by MIP.
Malaysian Institute Of Planners
16756215
English
Article
All Open Access; Hybrid Gold Open Access
author Khalid M.K.A.; Zawawi Z.A.; Ahmad N.A.; Zahari N.F.; Hashim H.
spellingShingle Khalid M.K.A.; Zawawi Z.A.; Ahmad N.A.; Zahari N.F.; Hashim H.
EVALUATING THE IMPACT OF DESIGN FAILURE ON THE PERAK TENGAH DISTRICT MOSQUE, PERAK, MALAYSIA
author_facet Khalid M.K.A.; Zawawi Z.A.; Ahmad N.A.; Zahari N.F.; Hashim H.
author_sort Khalid M.K.A.; Zawawi Z.A.; Ahmad N.A.; Zahari N.F.; Hashim H.
title EVALUATING THE IMPACT OF DESIGN FAILURE ON THE PERAK TENGAH DISTRICT MOSQUE, PERAK, MALAYSIA
title_short EVALUATING THE IMPACT OF DESIGN FAILURE ON THE PERAK TENGAH DISTRICT MOSQUE, PERAK, MALAYSIA
title_full EVALUATING THE IMPACT OF DESIGN FAILURE ON THE PERAK TENGAH DISTRICT MOSQUE, PERAK, MALAYSIA
title_fullStr EVALUATING THE IMPACT OF DESIGN FAILURE ON THE PERAK TENGAH DISTRICT MOSQUE, PERAK, MALAYSIA
title_full_unstemmed EVALUATING THE IMPACT OF DESIGN FAILURE ON THE PERAK TENGAH DISTRICT MOSQUE, PERAK, MALAYSIA
title_sort EVALUATING THE IMPACT OF DESIGN FAILURE ON THE PERAK TENGAH DISTRICT MOSQUE, PERAK, MALAYSIA
publishDate 2024
container_title Planning Malaysia
container_volume 22
container_issue 6
doi_str_mv 10.21837/pm.v22i34.1624
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85210931323&doi=10.21837%2fpm.v22i34.1624&partnerID=40&md5=8bb7599f88f83c08a87cc38ec04996ed
description This study investigates how building structural defects affect maintenance management in mosques in the Perak Tengah District. As well as offering suggestions for improving maintenance effectiveness, it draws attention to the fundamental design defects that cause issues with maintenance. A literature study, semi-structured interviews, observation, and a survey were used to collect the data. According to the goal of this study, inadequate site supervision, an inadequate cover of reinforcing concrete, poor structural design, noncompliance with specifications, improperly placed or applied paint, and a failure to specify suitable materials are the main design flaws that lead to maintenance issues. These defects result in increased maintenance expenses, job loads, the labour force, and the frequency of maintenance. Based on the study, all departments should collaborate and employ weather-resistant materials to improve job standards and building upkeep. © 2024 by MIP.
publisher Malaysian Institute Of Planners
issn 16756215
language English
format Article
accesstype All Open Access; Hybrid Gold Open Access
record_format scopus
collection Scopus
_version_ 1820775436832997376