Corrosivity of Earthing Electrode (Galvanized Tape) in Various Soil Locations for TNBR Transmission Tower

Tenaga Nasional Berhad (TNB) transmission towers carrying electrical lines are earthed by earthing electrodes. They are at risk of corrosion due to being fully submerged in soil for long periods and periodical maintenance of these towers can be a challenge as some of the sites of these towers are ha...

Full description

Bibliographic Details
Published in:Chemical Engineering Transactions
Main Author: Jarni H.H.; Amir Hisham N.I.; Hatta N.M.; Manaf F.; Yaakob N.
Format: Article
Language:English
Published: Italian Association of Chemical Engineering - AIDIC 2024
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85207916393&doi=10.3303%2fCET24112041&partnerID=40&md5=7a8cc86a3f1903e8712b06ac7d0ed880
id 2-s2.0-85207916393
spelling 2-s2.0-85207916393
Jarni H.H.; Amir Hisham N.I.; Hatta N.M.; Manaf F.; Yaakob N.
Corrosivity of Earthing Electrode (Galvanized Tape) in Various Soil Locations for TNBR Transmission Tower
2024
Chemical Engineering Transactions
112

10.3303/CET24112041
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85207916393&doi=10.3303%2fCET24112041&partnerID=40&md5=7a8cc86a3f1903e8712b06ac7d0ed880
Tenaga Nasional Berhad (TNB) transmission towers carrying electrical lines are earthed by earthing electrodes. They are at risk of corrosion due to being fully submerged in soil for long periods and periodical maintenance of these towers can be a challenge as some of the sites of these towers are hard to access. Previous research on galvanized tape as earthing electrodes was limited to certain locations, and subsequently, only focused on certain types of soils. Moreover, there is no prediction of the lifespan of earthing electrodes using galvanized tape, which is crucial information for industry. Hence, the objective of this study is to determine the corrosion rate of galvanized tape in various soil types in Malaysia by the Weight Loss Method (ASTM G1-03). Soils from four locations from Ulu Bernam, Teluk Kalong, Merlimau, and Gelang Patah are analyzed to identify the soil types and compositions, followed by a corrosion lab-based experiment for 14 days. The mass reductions of the corroded galvanized tapes were measured to determine the corrosion rate with pH values monitored daily. Results revealed that the soil type and area influence the corrosion of the galvanized tape with the average lifespan of galvanized tape in Malaysian peat soil being 7.2 years. Copyright © 2024, AIDIC Servizi S.r.l.
Italian Association of Chemical Engineering - AIDIC
22839216
English
Article

author Jarni H.H.; Amir Hisham N.I.; Hatta N.M.; Manaf F.; Yaakob N.
spellingShingle Jarni H.H.; Amir Hisham N.I.; Hatta N.M.; Manaf F.; Yaakob N.
Corrosivity of Earthing Electrode (Galvanized Tape) in Various Soil Locations for TNBR Transmission Tower
author_facet Jarni H.H.; Amir Hisham N.I.; Hatta N.M.; Manaf F.; Yaakob N.
author_sort Jarni H.H.; Amir Hisham N.I.; Hatta N.M.; Manaf F.; Yaakob N.
title Corrosivity of Earthing Electrode (Galvanized Tape) in Various Soil Locations for TNBR Transmission Tower
title_short Corrosivity of Earthing Electrode (Galvanized Tape) in Various Soil Locations for TNBR Transmission Tower
title_full Corrosivity of Earthing Electrode (Galvanized Tape) in Various Soil Locations for TNBR Transmission Tower
title_fullStr Corrosivity of Earthing Electrode (Galvanized Tape) in Various Soil Locations for TNBR Transmission Tower
title_full_unstemmed Corrosivity of Earthing Electrode (Galvanized Tape) in Various Soil Locations for TNBR Transmission Tower
title_sort Corrosivity of Earthing Electrode (Galvanized Tape) in Various Soil Locations for TNBR Transmission Tower
publishDate 2024
container_title Chemical Engineering Transactions
container_volume 112
container_issue
doi_str_mv 10.3303/CET24112041
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85207916393&doi=10.3303%2fCET24112041&partnerID=40&md5=7a8cc86a3f1903e8712b06ac7d0ed880
description Tenaga Nasional Berhad (TNB) transmission towers carrying electrical lines are earthed by earthing electrodes. They are at risk of corrosion due to being fully submerged in soil for long periods and periodical maintenance of these towers can be a challenge as some of the sites of these towers are hard to access. Previous research on galvanized tape as earthing electrodes was limited to certain locations, and subsequently, only focused on certain types of soils. Moreover, there is no prediction of the lifespan of earthing electrodes using galvanized tape, which is crucial information for industry. Hence, the objective of this study is to determine the corrosion rate of galvanized tape in various soil types in Malaysia by the Weight Loss Method (ASTM G1-03). Soils from four locations from Ulu Bernam, Teluk Kalong, Merlimau, and Gelang Patah are analyzed to identify the soil types and compositions, followed by a corrosion lab-based experiment for 14 days. The mass reductions of the corroded galvanized tapes were measured to determine the corrosion rate with pH values monitored daily. Results revealed that the soil type and area influence the corrosion of the galvanized tape with the average lifespan of galvanized tape in Malaysian peat soil being 7.2 years. Copyright © 2024, AIDIC Servizi S.r.l.
publisher Italian Association of Chemical Engineering - AIDIC
issn 22839216
language English
format Article
accesstype
record_format scopus
collection Scopus
_version_ 1818940551255293952