Comprehensive Evaluation of Generator Insulation Health: Electrical Testing Techniques

This paper presents a comprehensive study on the electrical testing of a turbine generator. The aim is to assess the condition of the generator's insulation system and overall electrical health through various diagnostic tests. Key methodologies include the Tan Delta (TD) Test, Partial Discharg...

Full description

Bibliographic Details
Published in:2024 IEEE 15th Control and System Graduate Research Colloquium, ICSGRC 2024 - Conference Proceeding
Main Author: Majid M.H.H.A.; Samsuddin N.M.; Rahman A.S.A.; Ali N.H.N.; Rahiman M.H.F.
Format: Conference paper
Language:English
Published: Institute of Electrical and Electronics Engineers Inc. 2024
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85206608669&doi=10.1109%2fICSGRC62081.2024.10691121&partnerID=40&md5=072bce525f39f10eb9f06611001b0b1f
id 2-s2.0-85206608669
spelling 2-s2.0-85206608669
Majid M.H.H.A.; Samsuddin N.M.; Rahman A.S.A.; Ali N.H.N.; Rahiman M.H.F.
Comprehensive Evaluation of Generator Insulation Health: Electrical Testing Techniques
2024
2024 IEEE 15th Control and System Graduate Research Colloquium, ICSGRC 2024 - Conference Proceeding


10.1109/ICSGRC62081.2024.10691121
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85206608669&doi=10.1109%2fICSGRC62081.2024.10691121&partnerID=40&md5=072bce525f39f10eb9f06611001b0b1f
This paper presents a comprehensive study on the electrical testing of a turbine generator. The aim is to assess the condition of the generator's insulation system and overall electrical health through various diagnostic tests. Key methodologies include the Tan Delta (TD) Test, Partial Discharge (PD) measurement, Resistance-to-Ground (RTG), Capacitance-to-Ground (CTG), Phase-to-Phase Inductance measurement, and the Polarization Index (PI). The TD Test evaluates the insulation quality by measuring the dissipation factor, indicating the extent of insulation deterioration. PD measurement detects electrical discharges that signify insulation defects. RTG testing determines the effectiveness of the insulation system in preventing leakage currents. CTG testing identifies contamination buildup on the windings. Phase-to-Phase Inductance measurement assesses the inductive properties and identifies potential winding deformations. The Polarization Index provides insights into the insulation's dryness and cleanliness. The results indicate that the generator is in generally acceptable condition, with recommendations for periodic monitoring to ensure sustained reliability and performance. This paper underscores the importance of regular and thorough electrical testing in maintaining the operational integrity of high-voltage generators. © 2024 IEEE.
Institute of Electrical and Electronics Engineers Inc.

English
Conference paper

author Majid M.H.H.A.; Samsuddin N.M.; Rahman A.S.A.; Ali N.H.N.; Rahiman M.H.F.
spellingShingle Majid M.H.H.A.; Samsuddin N.M.; Rahman A.S.A.; Ali N.H.N.; Rahiman M.H.F.
Comprehensive Evaluation of Generator Insulation Health: Electrical Testing Techniques
author_facet Majid M.H.H.A.; Samsuddin N.M.; Rahman A.S.A.; Ali N.H.N.; Rahiman M.H.F.
author_sort Majid M.H.H.A.; Samsuddin N.M.; Rahman A.S.A.; Ali N.H.N.; Rahiman M.H.F.
title Comprehensive Evaluation of Generator Insulation Health: Electrical Testing Techniques
title_short Comprehensive Evaluation of Generator Insulation Health: Electrical Testing Techniques
title_full Comprehensive Evaluation of Generator Insulation Health: Electrical Testing Techniques
title_fullStr Comprehensive Evaluation of Generator Insulation Health: Electrical Testing Techniques
title_full_unstemmed Comprehensive Evaluation of Generator Insulation Health: Electrical Testing Techniques
title_sort Comprehensive Evaluation of Generator Insulation Health: Electrical Testing Techniques
publishDate 2024
container_title 2024 IEEE 15th Control and System Graduate Research Colloquium, ICSGRC 2024 - Conference Proceeding
container_volume
container_issue
doi_str_mv 10.1109/ICSGRC62081.2024.10691121
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85206608669&doi=10.1109%2fICSGRC62081.2024.10691121&partnerID=40&md5=072bce525f39f10eb9f06611001b0b1f
description This paper presents a comprehensive study on the electrical testing of a turbine generator. The aim is to assess the condition of the generator's insulation system and overall electrical health through various diagnostic tests. Key methodologies include the Tan Delta (TD) Test, Partial Discharge (PD) measurement, Resistance-to-Ground (RTG), Capacitance-to-Ground (CTG), Phase-to-Phase Inductance measurement, and the Polarization Index (PI). The TD Test evaluates the insulation quality by measuring the dissipation factor, indicating the extent of insulation deterioration. PD measurement detects electrical discharges that signify insulation defects. RTG testing determines the effectiveness of the insulation system in preventing leakage currents. CTG testing identifies contamination buildup on the windings. Phase-to-Phase Inductance measurement assesses the inductive properties and identifies potential winding deformations. The Polarization Index provides insights into the insulation's dryness and cleanliness. The results indicate that the generator is in generally acceptable condition, with recommendations for periodic monitoring to ensure sustained reliability and performance. This paper underscores the importance of regular and thorough electrical testing in maintaining the operational integrity of high-voltage generators. © 2024 IEEE.
publisher Institute of Electrical and Electronics Engineers Inc.