The Characteristics of Dissolved Oxygen and Temperature Sensors in a Fishpond

Water quality is the most vital component influencing fish well-being and execution in aquaculture generation frameworks. Good water quality refers to a suitable condition for pond fish production. The main problem with the fishpond water quality is that the fishpond owner can't detect the prob...

Full description

Bibliographic Details
Published in:2024 IEEE International Conference on Applied Electronics and Engineering, ICAEE 2024
Main Author: Hashim H.; Zohri M.F.A.; Saad P.S.M.; Shariffudin S.S.; Harun Z.
Format: Conference paper
Language:English
Published: Institute of Electrical and Electronics Engineers Inc. 2024
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85204771657&doi=10.1109%2fICAEE62924.2024.10667487&partnerID=40&md5=9f3677e08e3c32abc29cfd352d0b135a
id 2-s2.0-85204771657
spelling 2-s2.0-85204771657
Hashim H.; Zohri M.F.A.; Saad P.S.M.; Shariffudin S.S.; Harun Z.
The Characteristics of Dissolved Oxygen and Temperature Sensors in a Fishpond
2024
2024 IEEE International Conference on Applied Electronics and Engineering, ICAEE 2024


10.1109/ICAEE62924.2024.10667487
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85204771657&doi=10.1109%2fICAEE62924.2024.10667487&partnerID=40&md5=9f3677e08e3c32abc29cfd352d0b135a
Water quality is the most vital component influencing fish well-being and execution in aquaculture generation frameworks. Good water quality refers to a suitable condition for pond fish production. The main problem with the fishpond water quality is that the fishpond owner can't detect the problem in the water that could affect the condition of the fish. This project aims to investigate the relationship between dissolved oxygen and temperature in the fishpond. The research involved the use of sensors for measuring dissolved oxygen and temperature. The sensors were connected to the Arduino Mega 2560 to obtain the output of the data from the sensors that were assembled at the fishpond. For this project, research was done to make sure that the condition of the water becomes neutral and suitable for the fish to live. It also helps the reproduction of the fish become larger. As a result, the relationship between the two parameters can be observed and monitored. The results indicate that during the daytime, the dissolved oxygen and temperature values were 29.88°C and 7.57 mg/L, respectively. At nighttime, the values remained the same at 29.88°C and 7.57 mg/L. In conclusion, this research showed that the condition of the parameters in the water would affect the reproduction of the fish and make sure that their fish can stay healthy. © 2024 IEEE.
Institute of Electrical and Electronics Engineers Inc.

English
Conference paper

author Hashim H.; Zohri M.F.A.; Saad P.S.M.; Shariffudin S.S.; Harun Z.
spellingShingle Hashim H.; Zohri M.F.A.; Saad P.S.M.; Shariffudin S.S.; Harun Z.
The Characteristics of Dissolved Oxygen and Temperature Sensors in a Fishpond
author_facet Hashim H.; Zohri M.F.A.; Saad P.S.M.; Shariffudin S.S.; Harun Z.
author_sort Hashim H.; Zohri M.F.A.; Saad P.S.M.; Shariffudin S.S.; Harun Z.
title The Characteristics of Dissolved Oxygen and Temperature Sensors in a Fishpond
title_short The Characteristics of Dissolved Oxygen and Temperature Sensors in a Fishpond
title_full The Characteristics of Dissolved Oxygen and Temperature Sensors in a Fishpond
title_fullStr The Characteristics of Dissolved Oxygen and Temperature Sensors in a Fishpond
title_full_unstemmed The Characteristics of Dissolved Oxygen and Temperature Sensors in a Fishpond
title_sort The Characteristics of Dissolved Oxygen and Temperature Sensors in a Fishpond
publishDate 2024
container_title 2024 IEEE International Conference on Applied Electronics and Engineering, ICAEE 2024
container_volume
container_issue
doi_str_mv 10.1109/ICAEE62924.2024.10667487
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85204771657&doi=10.1109%2fICAEE62924.2024.10667487&partnerID=40&md5=9f3677e08e3c32abc29cfd352d0b135a
description Water quality is the most vital component influencing fish well-being and execution in aquaculture generation frameworks. Good water quality refers to a suitable condition for pond fish production. The main problem with the fishpond water quality is that the fishpond owner can't detect the problem in the water that could affect the condition of the fish. This project aims to investigate the relationship between dissolved oxygen and temperature in the fishpond. The research involved the use of sensors for measuring dissolved oxygen and temperature. The sensors were connected to the Arduino Mega 2560 to obtain the output of the data from the sensors that were assembled at the fishpond. For this project, research was done to make sure that the condition of the water becomes neutral and suitable for the fish to live. It also helps the reproduction of the fish become larger. As a result, the relationship between the two parameters can be observed and monitored. The results indicate that during the daytime, the dissolved oxygen and temperature values were 29.88°C and 7.57 mg/L, respectively. At nighttime, the values remained the same at 29.88°C and 7.57 mg/L. In conclusion, this research showed that the condition of the parameters in the water would affect the reproduction of the fish and make sure that their fish can stay healthy. © 2024 IEEE.
publisher Institute of Electrical and Electronics Engineers Inc.
issn
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1814778502015090688