EXPLORING THE EFFICACY OF PIEZOELECTRIC-BASED SENSORY SYSTEMS FOR HEART RATE MONITORING IN DIFFERENTIATING STRESS VS RELAX CONDITIONS
Stress has diverse effects on human physiological reactions, and one such effect is on heart rate (HR). The established methods to acquire HR is by electrocardiogram (ECG) and photoplethysmogram (PPG). ECG electrodes need to be placed on the chest, which can cause inconvenience and is not practical...
Published in: | IIUM Engineering Journal |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Published: |
International Islamic University Malaysia-IIUM
2024
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85199789125&doi=10.31436%2fiiumej.v25i2.3017&partnerID=40&md5=f7c029e6b25b95efa960de72c6c607a9 |
id |
2-s2.0-85199789125 |
---|---|
spelling |
2-s2.0-85199789125 Zulkifli M.H.Z.; Jasni F.; Ghazali A.S.; Nordin N.H.D.; Sidek S.N.; Shaharum S.M.; Zaman F.H.K. EXPLORING THE EFFICACY OF PIEZOELECTRIC-BASED SENSORY SYSTEMS FOR HEART RATE MONITORING IN DIFFERENTIATING STRESS VS RELAX CONDITIONS 2024 IIUM Engineering Journal 25 2 10.31436/iiumej.v25i2.3017 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85199789125&doi=10.31436%2fiiumej.v25i2.3017&partnerID=40&md5=f7c029e6b25b95efa960de72c6c607a9 Stress has diverse effects on human physiological reactions, and one such effect is on heart rate (HR). The established methods to acquire HR is by electrocardiogram (ECG) and photoplethysmogram (PPG). ECG electrodes need to be placed on the chest, which can cause inconvenience and is not practical in daily life, while PPG signals are known to contain more noise than ECG. Thus, this work aims to investigate the efficacy of a piezoelectric-based sensory system in measuring HR and using the signal to differentiate stressed and relaxed conditions by means of statistical analysis. Two activities were conducted to achieve the goal. The first experiment involved collecting and analysing piezoelectric signals to measure the pulse rate (bpm) and compare this with the HR from PPG. For the second experiment, the piezoelectric-based HR was calculated from 20 subjects (male and female, age ranging between 20 and 25) in relaxed and stressed conditions. The stress condition was triggered using two stressors: the Stroop Colour Word Test and the Digit Span Test. Statistical analyses reveal a strong positive correlation between piezoelectric-based heart rate (HR) and oximeter readings (r(12) = 0.993, p < 0.001), despite the fact that the values are not precisely identical. In addition, the findings also indicate that there are significant effects by the mental states (stressed and relaxed) on the piezoelectric-based HR readings (p<0.05). Employing a within-subject design condition, the results further illustrated that piezoelectric readings are elevated during stressed conditions (Mean±SD = 72.395±0.097) and diminished during relaxed conditions (Mean±SD = 71.615±0.126). Therefore, the suggested piezoelectric-based sensory system has been validated as an effective means of categorizing stress and relaxation based on heart rate signals. © (2024), (International Islamic University Malaysia-IIUM). All rights reserved. International Islamic University Malaysia-IIUM 1511788X English Article All Open Access; Gold Open Access |
author |
Zulkifli M.H.Z.; Jasni F.; Ghazali A.S.; Nordin N.H.D.; Sidek S.N.; Shaharum S.M.; Zaman F.H.K. |
spellingShingle |
Zulkifli M.H.Z.; Jasni F.; Ghazali A.S.; Nordin N.H.D.; Sidek S.N.; Shaharum S.M.; Zaman F.H.K. EXPLORING THE EFFICACY OF PIEZOELECTRIC-BASED SENSORY SYSTEMS FOR HEART RATE MONITORING IN DIFFERENTIATING STRESS VS RELAX CONDITIONS |
author_facet |
Zulkifli M.H.Z.; Jasni F.; Ghazali A.S.; Nordin N.H.D.; Sidek S.N.; Shaharum S.M.; Zaman F.H.K. |
author_sort |
Zulkifli M.H.Z.; Jasni F.; Ghazali A.S.; Nordin N.H.D.; Sidek S.N.; Shaharum S.M.; Zaman F.H.K. |
title |
EXPLORING THE EFFICACY OF PIEZOELECTRIC-BASED SENSORY SYSTEMS FOR HEART RATE MONITORING IN DIFFERENTIATING STRESS VS RELAX CONDITIONS |
title_short |
EXPLORING THE EFFICACY OF PIEZOELECTRIC-BASED SENSORY SYSTEMS FOR HEART RATE MONITORING IN DIFFERENTIATING STRESS VS RELAX CONDITIONS |
title_full |
EXPLORING THE EFFICACY OF PIEZOELECTRIC-BASED SENSORY SYSTEMS FOR HEART RATE MONITORING IN DIFFERENTIATING STRESS VS RELAX CONDITIONS |
title_fullStr |
EXPLORING THE EFFICACY OF PIEZOELECTRIC-BASED SENSORY SYSTEMS FOR HEART RATE MONITORING IN DIFFERENTIATING STRESS VS RELAX CONDITIONS |
title_full_unstemmed |
EXPLORING THE EFFICACY OF PIEZOELECTRIC-BASED SENSORY SYSTEMS FOR HEART RATE MONITORING IN DIFFERENTIATING STRESS VS RELAX CONDITIONS |
title_sort |
EXPLORING THE EFFICACY OF PIEZOELECTRIC-BASED SENSORY SYSTEMS FOR HEART RATE MONITORING IN DIFFERENTIATING STRESS VS RELAX CONDITIONS |
publishDate |
2024 |
container_title |
IIUM Engineering Journal |
container_volume |
25 |
container_issue |
2 |
doi_str_mv |
10.31436/iiumej.v25i2.3017 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85199789125&doi=10.31436%2fiiumej.v25i2.3017&partnerID=40&md5=f7c029e6b25b95efa960de72c6c607a9 |
description |
Stress has diverse effects on human physiological reactions, and one such effect is on heart rate (HR). The established methods to acquire HR is by electrocardiogram (ECG) and photoplethysmogram (PPG). ECG electrodes need to be placed on the chest, which can cause inconvenience and is not practical in daily life, while PPG signals are known to contain more noise than ECG. Thus, this work aims to investigate the efficacy of a piezoelectric-based sensory system in measuring HR and using the signal to differentiate stressed and relaxed conditions by means of statistical analysis. Two activities were conducted to achieve the goal. The first experiment involved collecting and analysing piezoelectric signals to measure the pulse rate (bpm) and compare this with the HR from PPG. For the second experiment, the piezoelectric-based HR was calculated from 20 subjects (male and female, age ranging between 20 and 25) in relaxed and stressed conditions. The stress condition was triggered using two stressors: the Stroop Colour Word Test and the Digit Span Test. Statistical analyses reveal a strong positive correlation between piezoelectric-based heart rate (HR) and oximeter readings (r(12) = 0.993, p < 0.001), despite the fact that the values are not precisely identical. In addition, the findings also indicate that there are significant effects by the mental states (stressed and relaxed) on the piezoelectric-based HR readings (p<0.05). Employing a within-subject design condition, the results further illustrated that piezoelectric readings are elevated during stressed conditions (Mean±SD = 72.395±0.097) and diminished during relaxed conditions (Mean±SD = 71.615±0.126). Therefore, the suggested piezoelectric-based sensory system has been validated as an effective means of categorizing stress and relaxation based on heart rate signals. © (2024), (International Islamic University Malaysia-IIUM). All rights reserved. |
publisher |
International Islamic University Malaysia-IIUM |
issn |
1511788X |
language |
English |
format |
Article |
accesstype |
All Open Access; Gold Open Access |
record_format |
scopus |
collection |
Scopus |
_version_ |
1814778502789988352 |