Spectrophotometric Detection of Fe3+ Ion Based on Alizarin Red S (ARS) Reagent

Metal ions such as iro(III) ion (Fe3+) have an impact on human health and also play an important function in biological systems. However, the negative effects of Fe3+ ion to human and environment motivate the researchers to find a simple and quick method for Fe3+ detection. The aim of this study is...

Full description

Bibliographic Details
Published in:Malaysian Journal of Chemistry
Main Author: Zulkefli N.A.; Wan Khalid W.E.F.
Format: Article
Language:English
Published: Malaysian Institute of Chemistry 2024
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85198047111&doi=10.55373%2fmjchem.v26i3.320&partnerID=40&md5=dafbaf992c0c3cc13ce708dc7a4dbb6f
id 2-s2.0-85198047111
spelling 2-s2.0-85198047111
Zulkefli N.A.; Wan Khalid W.E.F.
Spectrophotometric Detection of Fe3+ Ion Based on Alizarin Red S (ARS) Reagent
2024
Malaysian Journal of Chemistry
26
3
10.55373/mjchem.v26i3.320
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85198047111&doi=10.55373%2fmjchem.v26i3.320&partnerID=40&md5=dafbaf992c0c3cc13ce708dc7a4dbb6f
Metal ions such as iro(III) ion (Fe3+) have an impact on human health and also play an important function in biological systems. However, the negative effects of Fe3+ ion to human and environment motivate the researchers to find a simple and quick method for Fe3+ detection. The aim of this study is to develop a simple method for determination of Fe3+ ion using Alizarin Red S (ARS) reagent. The reaction between ARS and Fe3+ ion has produced ARS-Fe(III) blackish-brown complex. All the optimization studies were carried out using UV-Vis Spectrophotometer at 572 nm. A dynamic linear range in acetate buffer solution was obtained in the range of 0.02 - 0.25 M with R2 value of 0.9909. Moreover, stability study indicated that ARS showed stable response for about 7 hours while the reproducibility study was found to give a satisfactory relative standard deviation (RSD) value of 1.63 % and 0.85 %. Based on the interference study, Al3+ and Ca2+ were found to not significantly interfere in the detection of Fe3+ ion while Cu2+ showed some interference. This proposed method is deemed simple and could be a promising method for a rapid and direct detection of Fe3+ ion in both qualitative and quantitative approaches. © 2024 Malaysian Institute of Chemistry. All rights reserved.
Malaysian Institute of Chemistry
15112292
English
Article

author Zulkefli N.A.; Wan Khalid W.E.F.
spellingShingle Zulkefli N.A.; Wan Khalid W.E.F.
Spectrophotometric Detection of Fe3+ Ion Based on Alizarin Red S (ARS) Reagent
author_facet Zulkefli N.A.; Wan Khalid W.E.F.
author_sort Zulkefli N.A.; Wan Khalid W.E.F.
title Spectrophotometric Detection of Fe3+ Ion Based on Alizarin Red S (ARS) Reagent
title_short Spectrophotometric Detection of Fe3+ Ion Based on Alizarin Red S (ARS) Reagent
title_full Spectrophotometric Detection of Fe3+ Ion Based on Alizarin Red S (ARS) Reagent
title_fullStr Spectrophotometric Detection of Fe3+ Ion Based on Alizarin Red S (ARS) Reagent
title_full_unstemmed Spectrophotometric Detection of Fe3+ Ion Based on Alizarin Red S (ARS) Reagent
title_sort Spectrophotometric Detection of Fe3+ Ion Based on Alizarin Red S (ARS) Reagent
publishDate 2024
container_title Malaysian Journal of Chemistry
container_volume 26
container_issue 3
doi_str_mv 10.55373/mjchem.v26i3.320
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85198047111&doi=10.55373%2fmjchem.v26i3.320&partnerID=40&md5=dafbaf992c0c3cc13ce708dc7a4dbb6f
description Metal ions such as iro(III) ion (Fe3+) have an impact on human health and also play an important function in biological systems. However, the negative effects of Fe3+ ion to human and environment motivate the researchers to find a simple and quick method for Fe3+ detection. The aim of this study is to develop a simple method for determination of Fe3+ ion using Alizarin Red S (ARS) reagent. The reaction between ARS and Fe3+ ion has produced ARS-Fe(III) blackish-brown complex. All the optimization studies were carried out using UV-Vis Spectrophotometer at 572 nm. A dynamic linear range in acetate buffer solution was obtained in the range of 0.02 - 0.25 M with R2 value of 0.9909. Moreover, stability study indicated that ARS showed stable response for about 7 hours while the reproducibility study was found to give a satisfactory relative standard deviation (RSD) value of 1.63 % and 0.85 %. Based on the interference study, Al3+ and Ca2+ were found to not significantly interfere in the detection of Fe3+ ion while Cu2+ showed some interference. This proposed method is deemed simple and could be a promising method for a rapid and direct detection of Fe3+ ion in both qualitative and quantitative approaches. © 2024 Malaysian Institute of Chemistry. All rights reserved.
publisher Malaysian Institute of Chemistry
issn 15112292
language English
format Article
accesstype
record_format scopus
collection Scopus
_version_ 1809678154481008640