Spectrophotometric Detection of Fe3+ Ion Based on Alizarin Red S (ARS) Reagent
Metal ions such as iro(III) ion (Fe3+) have an impact on human health and also play an important function in biological systems. However, the negative effects of Fe3+ ion to human and environment motivate the researchers to find a simple and quick method for Fe3+ detection. The aim of this study is...
Published in: | Malaysian Journal of Chemistry |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Published: |
Malaysian Institute of Chemistry
2024
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85198047111&doi=10.55373%2fmjchem.v26i3.320&partnerID=40&md5=dafbaf992c0c3cc13ce708dc7a4dbb6f |
id |
2-s2.0-85198047111 |
---|---|
spelling |
2-s2.0-85198047111 Zulkefli N.A.; Wan Khalid W.E.F. Spectrophotometric Detection of Fe3+ Ion Based on Alizarin Red S (ARS) Reagent 2024 Malaysian Journal of Chemistry 26 3 10.55373/mjchem.v26i3.320 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85198047111&doi=10.55373%2fmjchem.v26i3.320&partnerID=40&md5=dafbaf992c0c3cc13ce708dc7a4dbb6f Metal ions such as iro(III) ion (Fe3+) have an impact on human health and also play an important function in biological systems. However, the negative effects of Fe3+ ion to human and environment motivate the researchers to find a simple and quick method for Fe3+ detection. The aim of this study is to develop a simple method for determination of Fe3+ ion using Alizarin Red S (ARS) reagent. The reaction between ARS and Fe3+ ion has produced ARS-Fe(III) blackish-brown complex. All the optimization studies were carried out using UV-Vis Spectrophotometer at 572 nm. A dynamic linear range in acetate buffer solution was obtained in the range of 0.02 - 0.25 M with R2 value of 0.9909. Moreover, stability study indicated that ARS showed stable response for about 7 hours while the reproducibility study was found to give a satisfactory relative standard deviation (RSD) value of 1.63 % and 0.85 %. Based on the interference study, Al3+ and Ca2+ were found to not significantly interfere in the detection of Fe3+ ion while Cu2+ showed some interference. This proposed method is deemed simple and could be a promising method for a rapid and direct detection of Fe3+ ion in both qualitative and quantitative approaches. © 2024 Malaysian Institute of Chemistry. All rights reserved. Malaysian Institute of Chemistry 15112292 English Article |
author |
Zulkefli N.A.; Wan Khalid W.E.F. |
spellingShingle |
Zulkefli N.A.; Wan Khalid W.E.F. Spectrophotometric Detection of Fe3+ Ion Based on Alizarin Red S (ARS) Reagent |
author_facet |
Zulkefli N.A.; Wan Khalid W.E.F. |
author_sort |
Zulkefli N.A.; Wan Khalid W.E.F. |
title |
Spectrophotometric Detection of Fe3+ Ion Based on Alizarin Red S (ARS) Reagent |
title_short |
Spectrophotometric Detection of Fe3+ Ion Based on Alizarin Red S (ARS) Reagent |
title_full |
Spectrophotometric Detection of Fe3+ Ion Based on Alizarin Red S (ARS) Reagent |
title_fullStr |
Spectrophotometric Detection of Fe3+ Ion Based on Alizarin Red S (ARS) Reagent |
title_full_unstemmed |
Spectrophotometric Detection of Fe3+ Ion Based on Alizarin Red S (ARS) Reagent |
title_sort |
Spectrophotometric Detection of Fe3+ Ion Based on Alizarin Red S (ARS) Reagent |
publishDate |
2024 |
container_title |
Malaysian Journal of Chemistry |
container_volume |
26 |
container_issue |
3 |
doi_str_mv |
10.55373/mjchem.v26i3.320 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85198047111&doi=10.55373%2fmjchem.v26i3.320&partnerID=40&md5=dafbaf992c0c3cc13ce708dc7a4dbb6f |
description |
Metal ions such as iro(III) ion (Fe3+) have an impact on human health and also play an important function in biological systems. However, the negative effects of Fe3+ ion to human and environment motivate the researchers to find a simple and quick method for Fe3+ detection. The aim of this study is to develop a simple method for determination of Fe3+ ion using Alizarin Red S (ARS) reagent. The reaction between ARS and Fe3+ ion has produced ARS-Fe(III) blackish-brown complex. All the optimization studies were carried out using UV-Vis Spectrophotometer at 572 nm. A dynamic linear range in acetate buffer solution was obtained in the range of 0.02 - 0.25 M with R2 value of 0.9909. Moreover, stability study indicated that ARS showed stable response for about 7 hours while the reproducibility study was found to give a satisfactory relative standard deviation (RSD) value of 1.63 % and 0.85 %. Based on the interference study, Al3+ and Ca2+ were found to not significantly interfere in the detection of Fe3+ ion while Cu2+ showed some interference. This proposed method is deemed simple and could be a promising method for a rapid and direct detection of Fe3+ ion in both qualitative and quantitative approaches. © 2024 Malaysian Institute of Chemistry. All rights reserved. |
publisher |
Malaysian Institute of Chemistry |
issn |
15112292 |
language |
English |
format |
Article |
accesstype |
|
record_format |
scopus |
collection |
Scopus |
_version_ |
1809678154481008640 |