Performance evaluation of an extended aeration treatment plant: a case study in Sarawak, Malaysia
The extended aeration system is a sewage treatment plant for domestic and industrial wastewater. This study evaluates the performance of an extended aeration treatment plant (EATP), located at Universiti Teknologi MARA Sarawak Branch which has operated for more than 20 years. The evaluation consists...
Published in: | International Journal of Environment and Waste Management |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Published: |
Inderscience Publishers
2024
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85197650817&doi=10.1504%2fIJEWM.2024.139243&partnerID=40&md5=6a1d613c5cf1f83d4ff1de76186ef8e9 |
id |
2-s2.0-85197650817 |
---|---|
spelling |
2-s2.0-85197650817 Rashid A.F.A.; Pahroraji M.E.H.M.; Adnan A.S.; Idris J.; Jeffary A.; Victor B.J.; Wakimin N.D.; Abdullah M.F.; Husen R. Performance evaluation of an extended aeration treatment plant: a case study in Sarawak, Malaysia 2024 International Journal of Environment and Waste Management 34 2 10.1504/IJEWM.2024.139243 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85197650817&doi=10.1504%2fIJEWM.2024.139243&partnerID=40&md5=6a1d613c5cf1f83d4ff1de76186ef8e9 The extended aeration system is a sewage treatment plant for domestic and industrial wastewater. This study evaluates the performance of an extended aeration treatment plant (EATP), located at Universiti Teknologi MARA Sarawak Branch which has operated for more than 20 years. The evaluation consists of the temperature, pH, turbidity, total suspended solids (TSS), and chemical oxygen demand (COD) of influent (raw wastewater) and effluent (treated wastewater). The results show that the temperature, pH, turbidity, TSS, COD, and BOD5, of the effluent were in the range of 29.0°C to 30.5°C, 7.2 to 7.4, 16.6 NTU to 64.1 NTU, 76.6 mg/L to 176.0 mg/L, 32.0 mg/L to 67.5 mg/L and 18.0 mg/L to 68.0 mg/L respectively. Overall, most of the parameters are within the Standard B of Department of Environment Malaysia excluding turbidity, TSS and BOD5, which were marginally high. The plant is considered functioning well, and proper maintenance service is essential to ensure the effluent is within the standard limit. Copyright © 2024 Inderscience Enterprises Ltd. Inderscience Publishers 14789876 English Article |
author |
Rashid A.F.A.; Pahroraji M.E.H.M.; Adnan A.S.; Idris J.; Jeffary A.; Victor B.J.; Wakimin N.D.; Abdullah M.F.; Husen R. |
spellingShingle |
Rashid A.F.A.; Pahroraji M.E.H.M.; Adnan A.S.; Idris J.; Jeffary A.; Victor B.J.; Wakimin N.D.; Abdullah M.F.; Husen R. Performance evaluation of an extended aeration treatment plant: a case study in Sarawak, Malaysia |
author_facet |
Rashid A.F.A.; Pahroraji M.E.H.M.; Adnan A.S.; Idris J.; Jeffary A.; Victor B.J.; Wakimin N.D.; Abdullah M.F.; Husen R. |
author_sort |
Rashid A.F.A.; Pahroraji M.E.H.M.; Adnan A.S.; Idris J.; Jeffary A.; Victor B.J.; Wakimin N.D.; Abdullah M.F.; Husen R. |
title |
Performance evaluation of an extended aeration treatment plant: a case study in Sarawak, Malaysia |
title_short |
Performance evaluation of an extended aeration treatment plant: a case study in Sarawak, Malaysia |
title_full |
Performance evaluation of an extended aeration treatment plant: a case study in Sarawak, Malaysia |
title_fullStr |
Performance evaluation of an extended aeration treatment plant: a case study in Sarawak, Malaysia |
title_full_unstemmed |
Performance evaluation of an extended aeration treatment plant: a case study in Sarawak, Malaysia |
title_sort |
Performance evaluation of an extended aeration treatment plant: a case study in Sarawak, Malaysia |
publishDate |
2024 |
container_title |
International Journal of Environment and Waste Management |
container_volume |
34 |
container_issue |
2 |
doi_str_mv |
10.1504/IJEWM.2024.139243 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85197650817&doi=10.1504%2fIJEWM.2024.139243&partnerID=40&md5=6a1d613c5cf1f83d4ff1de76186ef8e9 |
description |
The extended aeration system is a sewage treatment plant for domestic and industrial wastewater. This study evaluates the performance of an extended aeration treatment plant (EATP), located at Universiti Teknologi MARA Sarawak Branch which has operated for more than 20 years. The evaluation consists of the temperature, pH, turbidity, total suspended solids (TSS), and chemical oxygen demand (COD) of influent (raw wastewater) and effluent (treated wastewater). The results show that the temperature, pH, turbidity, TSS, COD, and BOD5, of the effluent were in the range of 29.0°C to 30.5°C, 7.2 to 7.4, 16.6 NTU to 64.1 NTU, 76.6 mg/L to 176.0 mg/L, 32.0 mg/L to 67.5 mg/L and 18.0 mg/L to 68.0 mg/L respectively. Overall, most of the parameters are within the Standard B of Department of Environment Malaysia excluding turbidity, TSS and BOD5, which were marginally high. The plant is considered functioning well, and proper maintenance service is essential to ensure the effluent is within the standard limit. Copyright © 2024 Inderscience Enterprises Ltd. |
publisher |
Inderscience Publishers |
issn |
14789876 |
language |
English |
format |
Article |
accesstype |
|
record_format |
scopus |
collection |
Scopus |
_version_ |
1809678475057954816 |