Investigation of the usage of zigzag transformers to reduce harmonics distortion in distribution systems

The increasing use of power electronics in various sectors leads to harmonic distortion in electric power systems, affecting power quality and equipment longevity. While harmonic filters have been used to address this issue, they are limited in effectiveness, particularly in reducing distortion acro...

Full description

Bibliographic Details
Published in:Journal of Mechatronics, Electrical Power, and Vehicular Technology
Main Author: Gumilar L.; Wicaksono I.A.; Afandi A.N.; Samat A.A.A.; Sias Q.A.
Format: Article
Language:English
Published: National Research and Innovation Agency (BRIN) 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85187174144&doi=10.14203%2fj.mev.2023.v14.138-149&partnerID=40&md5=9d03c7391fcc095eff839e82be0d910f
id 2-s2.0-85187174144
spelling 2-s2.0-85187174144
Gumilar L.; Wicaksono I.A.; Afandi A.N.; Samat A.A.A.; Sias Q.A.
Investigation of the usage of zigzag transformers to reduce harmonics distortion in distribution systems
2023
Journal of Mechatronics, Electrical Power, and Vehicular Technology
14
2
10.14203/j.mev.2023.v14.138-149
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85187174144&doi=10.14203%2fj.mev.2023.v14.138-149&partnerID=40&md5=9d03c7391fcc095eff839e82be0d910f
The increasing use of power electronics in various sectors leads to harmonic distortion in electric power systems, affecting power quality and equipment longevity. While harmonic filters have been used to address this issue, they are limited in effectiveness, particularly in reducing distortion across the entire distribution system. This study aims to reduce harmonic distortion using a zigzag transformer as a more comprehensive solution in mitigating harmonic distortion throughout the entire distribution system. In this research, the zigzag transformer was placed at point common coupling to reduce harmonic distortion in the distribution system as a whole. A zigzag transformer connection was configured by connecting either three windings of a single-phase transformer or one winding of a three-phase transformer. Based on the results of this research, the total harmonic distortion (THD) value has decreased from 25.26 % to 2.48 % following the implementation of the zigzag transformer. This substantial decrease in THD concludes the zigzag transformer's effectiveness as a solution for improving power quality in electrical distribution systems. Copyright ©2023 National Research and Innovation Agency.
National Research and Innovation Agency (BRIN)
20873379
English
Article
All Open Access; Gold Open Access
author Gumilar L.; Wicaksono I.A.; Afandi A.N.; Samat A.A.A.; Sias Q.A.
spellingShingle Gumilar L.; Wicaksono I.A.; Afandi A.N.; Samat A.A.A.; Sias Q.A.
Investigation of the usage of zigzag transformers to reduce harmonics distortion in distribution systems
author_facet Gumilar L.; Wicaksono I.A.; Afandi A.N.; Samat A.A.A.; Sias Q.A.
author_sort Gumilar L.; Wicaksono I.A.; Afandi A.N.; Samat A.A.A.; Sias Q.A.
title Investigation of the usage of zigzag transformers to reduce harmonics distortion in distribution systems
title_short Investigation of the usage of zigzag transformers to reduce harmonics distortion in distribution systems
title_full Investigation of the usage of zigzag transformers to reduce harmonics distortion in distribution systems
title_fullStr Investigation of the usage of zigzag transformers to reduce harmonics distortion in distribution systems
title_full_unstemmed Investigation of the usage of zigzag transformers to reduce harmonics distortion in distribution systems
title_sort Investigation of the usage of zigzag transformers to reduce harmonics distortion in distribution systems
publishDate 2023
container_title Journal of Mechatronics, Electrical Power, and Vehicular Technology
container_volume 14
container_issue 2
doi_str_mv 10.14203/j.mev.2023.v14.138-149
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85187174144&doi=10.14203%2fj.mev.2023.v14.138-149&partnerID=40&md5=9d03c7391fcc095eff839e82be0d910f
description The increasing use of power electronics in various sectors leads to harmonic distortion in electric power systems, affecting power quality and equipment longevity. While harmonic filters have been used to address this issue, they are limited in effectiveness, particularly in reducing distortion across the entire distribution system. This study aims to reduce harmonic distortion using a zigzag transformer as a more comprehensive solution in mitigating harmonic distortion throughout the entire distribution system. In this research, the zigzag transformer was placed at point common coupling to reduce harmonic distortion in the distribution system as a whole. A zigzag transformer connection was configured by connecting either three windings of a single-phase transformer or one winding of a three-phase transformer. Based on the results of this research, the total harmonic distortion (THD) value has decreased from 25.26 % to 2.48 % following the implementation of the zigzag transformer. This substantial decrease in THD concludes the zigzag transformer's effectiveness as a solution for improving power quality in electrical distribution systems. Copyright ©2023 National Research and Innovation Agency.
publisher National Research and Innovation Agency (BRIN)
issn 20873379
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809677888787578880