Effect of Coated Tungsten Disulfide (WS2) on Tapered Optical Fibre for Urea Detection
It is crucial to detect urea in clinical samples because urea levels in biological fluids are clinically linked to a number of disorders, including dehydration, heart failure, and renal dysfunction. Here, a tungsten disulfide (WS2)-coated tapered optical fibre sensor with increased sensitivity is su...
Published in: | Journal of Advanced Research in Applied Sciences and Engineering Technology |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Published: |
Semarak Ilmu Publishing
2024
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85185507011&doi=10.37934%2faraset.39.2.181190&partnerID=40&md5=98104edd0d71b62cda4dad204d2780f0 |
id |
2-s2.0-85185507011 |
---|---|
spelling |
2-s2.0-85185507011 Burham N.; Bachok N.; Ali N.; Othman A.R.; Arsad N.; Awang A.H.; Isa N.M.; Li Z. Effect of Coated Tungsten Disulfide (WS2) on Tapered Optical Fibre for Urea Detection 2024 Journal of Advanced Research in Applied Sciences and Engineering Technology 39 2 10.37934/araset.39.2.181190 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85185507011&doi=10.37934%2faraset.39.2.181190&partnerID=40&md5=98104edd0d71b62cda4dad204d2780f0 It is crucial to detect urea in clinical samples because urea levels in biological fluids are clinically linked to a number of disorders, including dehydration, heart failure, and renal dysfunction. Here, a tungsten disulfide (WS2)-coated tapered optical fibre sensor with increased sensitivity is suggested and demonstrated. The findings have shown that the sensing sensitivity is greatly improved with WS2 coating on the tapered optical fibre. This improvement is made possible by the unique optoelectronic capabilities of the WS2 layer and the tapered diameter size. The coating of the 20 µm tapered diameter with 20 µL WS2 results in the maximum sensitivity (up to 0.069 dBm/(mg/dL)) in the experiment. This result demonstrates a sensitivity improvement of 60% compared to the scenario in which a WS2 coating was not present. Analysis and discussions are conducted on the sensing performance improvements brought about by the tapered diameter size and the WS2 coating. In addition, the WS2 tapered optical fibre sensor possesses a linear correlation coefficient of 99.8 % in a concentration range of 10–50 mg/dL. © 2024, Semarak Ilmu Publishing. All rights reserved. Semarak Ilmu Publishing 24621943 English Article All Open Access; Hybrid Gold Open Access |
author |
Burham N.; Bachok N.; Ali N.; Othman A.R.; Arsad N.; Awang A.H.; Isa N.M.; Li Z. |
spellingShingle |
Burham N.; Bachok N.; Ali N.; Othman A.R.; Arsad N.; Awang A.H.; Isa N.M.; Li Z. Effect of Coated Tungsten Disulfide (WS2) on Tapered Optical Fibre for Urea Detection |
author_facet |
Burham N.; Bachok N.; Ali N.; Othman A.R.; Arsad N.; Awang A.H.; Isa N.M.; Li Z. |
author_sort |
Burham N.; Bachok N.; Ali N.; Othman A.R.; Arsad N.; Awang A.H.; Isa N.M.; Li Z. |
title |
Effect of Coated Tungsten Disulfide (WS2) on Tapered Optical Fibre for Urea Detection |
title_short |
Effect of Coated Tungsten Disulfide (WS2) on Tapered Optical Fibre for Urea Detection |
title_full |
Effect of Coated Tungsten Disulfide (WS2) on Tapered Optical Fibre for Urea Detection |
title_fullStr |
Effect of Coated Tungsten Disulfide (WS2) on Tapered Optical Fibre for Urea Detection |
title_full_unstemmed |
Effect of Coated Tungsten Disulfide (WS2) on Tapered Optical Fibre for Urea Detection |
title_sort |
Effect of Coated Tungsten Disulfide (WS2) on Tapered Optical Fibre for Urea Detection |
publishDate |
2024 |
container_title |
Journal of Advanced Research in Applied Sciences and Engineering Technology |
container_volume |
39 |
container_issue |
2 |
doi_str_mv |
10.37934/araset.39.2.181190 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85185507011&doi=10.37934%2faraset.39.2.181190&partnerID=40&md5=98104edd0d71b62cda4dad204d2780f0 |
description |
It is crucial to detect urea in clinical samples because urea levels in biological fluids are clinically linked to a number of disorders, including dehydration, heart failure, and renal dysfunction. Here, a tungsten disulfide (WS2)-coated tapered optical fibre sensor with increased sensitivity is suggested and demonstrated. The findings have shown that the sensing sensitivity is greatly improved with WS2 coating on the tapered optical fibre. This improvement is made possible by the unique optoelectronic capabilities of the WS2 layer and the tapered diameter size. The coating of the 20 µm tapered diameter with 20 µL WS2 results in the maximum sensitivity (up to 0.069 dBm/(mg/dL)) in the experiment. This result demonstrates a sensitivity improvement of 60% compared to the scenario in which a WS2 coating was not present. Analysis and discussions are conducted on the sensing performance improvements brought about by the tapered diameter size and the WS2 coating. In addition, the WS2 tapered optical fibre sensor possesses a linear correlation coefficient of 99.8 % in a concentration range of 10–50 mg/dL. © 2024, Semarak Ilmu Publishing. All rights reserved. |
publisher |
Semarak Ilmu Publishing |
issn |
24621943 |
language |
English |
format |
Article |
accesstype |
All Open Access; Hybrid Gold Open Access |
record_format |
scopus |
collection |
Scopus |
_version_ |
1814778498522284032 |