Fault Identification Technique For Fault-Tolerant Boost Rectifier Based on SPMC Using Simulink/MATLAB

This paper presents an operation of the simulation model designed for fault identification within the proposed boost rectifier based on single-phase matrix converter (SPMC). The main goal of the fault identification technique is to locate a faulty switch during an open circuit fault (OCF) by observi...

Full description

Bibliographic Details
Published in:IEACon 2023 - 2023 IEEE Industrial Electronics and Applications Conference
Main Author: Hayroman M.H.; Muhammad K.S.; Baharom R.; Wan Abdul Munim W.N.
Format: Conference paper
Language:English
Published: Institute of Electrical and Electronics Engineers Inc. 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85182952976&doi=10.1109%2fIEACon57683.2023.10370632&partnerID=40&md5=f243186354506b98a8e5e8fd68e372b8
id 2-s2.0-85182952976
spelling 2-s2.0-85182952976
Hayroman M.H.; Muhammad K.S.; Baharom R.; Wan Abdul Munim W.N.
Fault Identification Technique For Fault-Tolerant Boost Rectifier Based on SPMC Using Simulink/MATLAB
2023
IEACon 2023 - 2023 IEEE Industrial Electronics and Applications Conference


10.1109/IEACon57683.2023.10370632
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85182952976&doi=10.1109%2fIEACon57683.2023.10370632&partnerID=40&md5=f243186354506b98a8e5e8fd68e372b8
This paper presents an operation of the simulation model designed for fault identification within the proposed boost rectifier based on single-phase matrix converter (SPMC). The main goal of the fault identification technique is to locate a faulty switch during an open circuit fault (OCF) by observing the output voltage, the cycle of input supply and magnitude of inductor current. This is done by generating a binary code that acts as a signal for a controller to activate the relevant Current Option Route (COR) strategy-a setup meant to redirect current to working switches when a OCF occurs, ensuring the required current pathway in the circuit. The switching operation of COR strategy and fault identification technique is presented using Simulink MATLAB. © 2023 IEEE.
Institute of Electrical and Electronics Engineers Inc.

English
Conference paper

author Hayroman M.H.; Muhammad K.S.; Baharom R.; Wan Abdul Munim W.N.
spellingShingle Hayroman M.H.; Muhammad K.S.; Baharom R.; Wan Abdul Munim W.N.
Fault Identification Technique For Fault-Tolerant Boost Rectifier Based on SPMC Using Simulink/MATLAB
author_facet Hayroman M.H.; Muhammad K.S.; Baharom R.; Wan Abdul Munim W.N.
author_sort Hayroman M.H.; Muhammad K.S.; Baharom R.; Wan Abdul Munim W.N.
title Fault Identification Technique For Fault-Tolerant Boost Rectifier Based on SPMC Using Simulink/MATLAB
title_short Fault Identification Technique For Fault-Tolerant Boost Rectifier Based on SPMC Using Simulink/MATLAB
title_full Fault Identification Technique For Fault-Tolerant Boost Rectifier Based on SPMC Using Simulink/MATLAB
title_fullStr Fault Identification Technique For Fault-Tolerant Boost Rectifier Based on SPMC Using Simulink/MATLAB
title_full_unstemmed Fault Identification Technique For Fault-Tolerant Boost Rectifier Based on SPMC Using Simulink/MATLAB
title_sort Fault Identification Technique For Fault-Tolerant Boost Rectifier Based on SPMC Using Simulink/MATLAB
publishDate 2023
container_title IEACon 2023 - 2023 IEEE Industrial Electronics and Applications Conference
container_volume
container_issue
doi_str_mv 10.1109/IEACon57683.2023.10370632
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85182952976&doi=10.1109%2fIEACon57683.2023.10370632&partnerID=40&md5=f243186354506b98a8e5e8fd68e372b8
description This paper presents an operation of the simulation model designed for fault identification within the proposed boost rectifier based on single-phase matrix converter (SPMC). The main goal of the fault identification technique is to locate a faulty switch during an open circuit fault (OCF) by observing the output voltage, the cycle of input supply and magnitude of inductor current. This is done by generating a binary code that acts as a signal for a controller to activate the relevant Current Option Route (COR) strategy-a setup meant to redirect current to working switches when a OCF occurs, ensuring the required current pathway in the circuit. The switching operation of COR strategy and fault identification technique is presented using Simulink MATLAB. © 2023 IEEE.
publisher Institute of Electrical and Electronics Engineers Inc.
issn
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1809677584659644416