Feasibility study on electricity generation in Kg. Sabur Pulau Banggi Malaysia from wind energy using HOMER software

The feasibility of electricity generation using wind turbine system in Kg. Sabur, Pulau Banggi, Sabah is studied by investigating the electrical load profile of Kg. Sabur and analyzing the techno-economic aspects. Pulau Banggi is an area that encountering with electricity shortage and the highlighte...

Full description

Bibliographic Details
Published in:IOP Conference Series: Earth and Environmental Science
Main Author: Kumar Y.N.S.; Makmud M.Z.H.; Hamid A.S.A.; Rahman A.B.A.; Miskon M.T.; Salleh S.
Format: Conference paper
Language:English
Published: Institute of Physics 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85182354077&doi=10.1088%2f1755-1315%2f1281%2f1%2f012031&partnerID=40&md5=62887e69bea882ed603588edd4f5ae1c
id 2-s2.0-85182354077
spelling 2-s2.0-85182354077
Kumar Y.N.S.; Makmud M.Z.H.; Hamid A.S.A.; Rahman A.B.A.; Miskon M.T.; Salleh S.
Feasibility study on electricity generation in Kg. Sabur Pulau Banggi Malaysia from wind energy using HOMER software
2023
IOP Conference Series: Earth and Environmental Science
1281
1
10.1088/1755-1315/1281/1/012031
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85182354077&doi=10.1088%2f1755-1315%2f1281%2f1%2f012031&partnerID=40&md5=62887e69bea882ed603588edd4f5ae1c
The feasibility of electricity generation using wind turbine system in Kg. Sabur, Pulau Banggi, Sabah is studied by investigating the electrical load profile of Kg. Sabur and analyzing the techno-economic aspects. Pulau Banggi is an area that encountering with electricity shortage and the highlighted location from Pulau Banggi that facing this issue is Kg. Sabur. The diesel generator, main electricity supply insufficient to meet the load requirement in Kg. Sabur. Survey data is used to develop the electrical load profile in HOMER software. The meteorological data such as wind speed, solar GHI and temperature are inputted into HOMER as well as components sizing and costs details. Comparison is made between four electrical systems on the aspects of electricity production, economics, fuel consumption and gas emission to evaluate the efficiency of the system with wind turbine. The total electrical load of residential area in Kg. Sabur is 888 kWh/day. Type 1 electrical system that consists of wind turbine, solar PV, battery, generator and converter is the most cost-effective and highly reliable system to be implement in Kg. Sabur. Electrical generation from wind energy is the most feasible system to implement in Kg. Sabur, Pulau Banggi, Kudat. © 2023 Institute of Physics Publishing. All rights reserved.
Institute of Physics
17551307
English
Conference paper
All Open Access; Gold Open Access
author Kumar Y.N.S.; Makmud M.Z.H.; Hamid A.S.A.; Rahman A.B.A.; Miskon M.T.; Salleh S.
spellingShingle Kumar Y.N.S.; Makmud M.Z.H.; Hamid A.S.A.; Rahman A.B.A.; Miskon M.T.; Salleh S.
Feasibility study on electricity generation in Kg. Sabur Pulau Banggi Malaysia from wind energy using HOMER software
author_facet Kumar Y.N.S.; Makmud M.Z.H.; Hamid A.S.A.; Rahman A.B.A.; Miskon M.T.; Salleh S.
author_sort Kumar Y.N.S.; Makmud M.Z.H.; Hamid A.S.A.; Rahman A.B.A.; Miskon M.T.; Salleh S.
title Feasibility study on electricity generation in Kg. Sabur Pulau Banggi Malaysia from wind energy using HOMER software
title_short Feasibility study on electricity generation in Kg. Sabur Pulau Banggi Malaysia from wind energy using HOMER software
title_full Feasibility study on electricity generation in Kg. Sabur Pulau Banggi Malaysia from wind energy using HOMER software
title_fullStr Feasibility study on electricity generation in Kg. Sabur Pulau Banggi Malaysia from wind energy using HOMER software
title_full_unstemmed Feasibility study on electricity generation in Kg. Sabur Pulau Banggi Malaysia from wind energy using HOMER software
title_sort Feasibility study on electricity generation in Kg. Sabur Pulau Banggi Malaysia from wind energy using HOMER software
publishDate 2023
container_title IOP Conference Series: Earth and Environmental Science
container_volume 1281
container_issue 1
doi_str_mv 10.1088/1755-1315/1281/1/012031
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85182354077&doi=10.1088%2f1755-1315%2f1281%2f1%2f012031&partnerID=40&md5=62887e69bea882ed603588edd4f5ae1c
description The feasibility of electricity generation using wind turbine system in Kg. Sabur, Pulau Banggi, Sabah is studied by investigating the electrical load profile of Kg. Sabur and analyzing the techno-economic aspects. Pulau Banggi is an area that encountering with electricity shortage and the highlighted location from Pulau Banggi that facing this issue is Kg. Sabur. The diesel generator, main electricity supply insufficient to meet the load requirement in Kg. Sabur. Survey data is used to develop the electrical load profile in HOMER software. The meteorological data such as wind speed, solar GHI and temperature are inputted into HOMER as well as components sizing and costs details. Comparison is made between four electrical systems on the aspects of electricity production, economics, fuel consumption and gas emission to evaluate the efficiency of the system with wind turbine. The total electrical load of residential area in Kg. Sabur is 888 kWh/day. Type 1 electrical system that consists of wind turbine, solar PV, battery, generator and converter is the most cost-effective and highly reliable system to be implement in Kg. Sabur. Electrical generation from wind energy is the most feasible system to implement in Kg. Sabur, Pulau Banggi, Kudat. © 2023 Institute of Physics Publishing. All rights reserved.
publisher Institute of Physics
issn 17551307
language English
format Conference paper
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809677585806786560