Structural Performance of Ti6Al4V Tibial Tray in Total Knee Arthroplasty (TKA) by Functionally Graded Lattice Structures using Numerical Analysis

The medical industry benefits greatly from the additive manufacturing (AM) technology used on customized products. Total knee arthroplasty (TKA) has been widely used however it has drawbacks of stress shielding and loosening due to the excessive daily routine of patients. The problem could be minimi...

Full description

Bibliographic Details
Published in:Journal of Mechanical Engineering
Main Author: Rabuan N.; Adenan M.S.; Manurung Y.H.P.; Anuar M.A.M.; Shuib S.
Format: Article
Language:English
Published: UiTM Press 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85182243024&doi=10.24191%2fJMECHE.V12I1.24643&partnerID=40&md5=e7fee763d70174410d18918bc6aa65fe
id 2-s2.0-85182243024
spelling 2-s2.0-85182243024
Rabuan N.; Adenan M.S.; Manurung Y.H.P.; Anuar M.A.M.; Shuib S.
Structural Performance of Ti6Al4V Tibial Tray in Total Knee Arthroplasty (TKA) by Functionally Graded Lattice Structures using Numerical Analysis
2023
Journal of Mechanical Engineering
SI12

10.24191/JMECHE.V12I1.24643
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85182243024&doi=10.24191%2fJMECHE.V12I1.24643&partnerID=40&md5=e7fee763d70174410d18918bc6aa65fe
The medical industry benefits greatly from the additive manufacturing (AM) technology used on customized products. Total knee arthroplasty (TKA) has been widely used however it has drawbacks of stress shielding and loosening due to the excessive daily routine of patients. The problem could be minimized by applying lattice structures to the implant and mimicking the actual density of human bone. This study aims to investigate the optimal design of a Ti6Al4V alloy tibial tray by applying different types of lattice structure designs. A finite element analysis was used to investigate the mechanical behavior of uniform and non-uniform lattice structures in a walking position. Functional gradation structure was optimized on selected regions of the tibial tray with weight reduction and adaptation to the near actual density of the human bone without compromising its mechanical performance. The results indicated that the Voronoi structure has improved stress behavior and the capability to withstand the loads exerted, based on the Von Mises stress result of the Voronoi structure at 35.83 MPa as compared to the gyroid and diamond structures at 61.65 MPa and 49.74 MPa, respectively. The optimal design of the tibial implant was achieved by functionally graded lattice structures, replacing the solid tibial implant. © 2023 College of Engineering, Universiti Teknologi MARA (UiTM), Malaysia. All Rights Reserved.
UiTM Press
18235514
English
Article
All Open Access; Bronze Open Access
author Rabuan N.; Adenan M.S.; Manurung Y.H.P.; Anuar M.A.M.; Shuib S.
spellingShingle Rabuan N.; Adenan M.S.; Manurung Y.H.P.; Anuar M.A.M.; Shuib S.
Structural Performance of Ti6Al4V Tibial Tray in Total Knee Arthroplasty (TKA) by Functionally Graded Lattice Structures using Numerical Analysis
author_facet Rabuan N.; Adenan M.S.; Manurung Y.H.P.; Anuar M.A.M.; Shuib S.
author_sort Rabuan N.; Adenan M.S.; Manurung Y.H.P.; Anuar M.A.M.; Shuib S.
title Structural Performance of Ti6Al4V Tibial Tray in Total Knee Arthroplasty (TKA) by Functionally Graded Lattice Structures using Numerical Analysis
title_short Structural Performance of Ti6Al4V Tibial Tray in Total Knee Arthroplasty (TKA) by Functionally Graded Lattice Structures using Numerical Analysis
title_full Structural Performance of Ti6Al4V Tibial Tray in Total Knee Arthroplasty (TKA) by Functionally Graded Lattice Structures using Numerical Analysis
title_fullStr Structural Performance of Ti6Al4V Tibial Tray in Total Knee Arthroplasty (TKA) by Functionally Graded Lattice Structures using Numerical Analysis
title_full_unstemmed Structural Performance of Ti6Al4V Tibial Tray in Total Knee Arthroplasty (TKA) by Functionally Graded Lattice Structures using Numerical Analysis
title_sort Structural Performance of Ti6Al4V Tibial Tray in Total Knee Arthroplasty (TKA) by Functionally Graded Lattice Structures using Numerical Analysis
publishDate 2023
container_title Journal of Mechanical Engineering
container_volume SI12
container_issue
doi_str_mv 10.24191/JMECHE.V12I1.24643
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85182243024&doi=10.24191%2fJMECHE.V12I1.24643&partnerID=40&md5=e7fee763d70174410d18918bc6aa65fe
description The medical industry benefits greatly from the additive manufacturing (AM) technology used on customized products. Total knee arthroplasty (TKA) has been widely used however it has drawbacks of stress shielding and loosening due to the excessive daily routine of patients. The problem could be minimized by applying lattice structures to the implant and mimicking the actual density of human bone. This study aims to investigate the optimal design of a Ti6Al4V alloy tibial tray by applying different types of lattice structure designs. A finite element analysis was used to investigate the mechanical behavior of uniform and non-uniform lattice structures in a walking position. Functional gradation structure was optimized on selected regions of the tibial tray with weight reduction and adaptation to the near actual density of the human bone without compromising its mechanical performance. The results indicated that the Voronoi structure has improved stress behavior and the capability to withstand the loads exerted, based on the Von Mises stress result of the Voronoi structure at 35.83 MPa as compared to the gyroid and diamond structures at 61.65 MPa and 49.74 MPa, respectively. The optimal design of the tibial implant was achieved by functionally graded lattice structures, replacing the solid tibial implant. © 2023 College of Engineering, Universiti Teknologi MARA (UiTM), Malaysia. All Rights Reserved.
publisher UiTM Press
issn 18235514
language English
format Article
accesstype All Open Access; Bronze Open Access
record_format scopus
collection Scopus
_version_ 1809677585636917248