Effect of the Electrodeposition Cycle of RGO Towards Glucose Detection
The author report on the synthesis of reduced graphene oxide (RGO) using electrodeposition method on screen printed gold electrode (SPGE). The RGO were deposited on the screen-printed gold electrode (SPGE) using cyclic voltammetry technique with different cycles of 3, 5 and 7 of voltage range from-1...
Published in: | Proceedings - 2023 IEEE Regional Symposium on Micro and Nanoelectronics, RSM 2023 |
---|---|
Main Author: | |
Format: | Conference paper |
Language: | English |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2023
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85179852138&doi=10.1109%2fRSM59033.2023.10327336&partnerID=40&md5=7a63d024e935772262cbb4ef9dbd0de6 |
id |
2-s2.0-85179852138 |
---|---|
spelling |
2-s2.0-85179852138 Ilias M.H.; Khairudin N.; Zoolfakar A.S.; Zolkapli M.; Zain Z.M.; Fitrah Abu Bakar N.; Rani R.A.; Manut A. Effect of the Electrodeposition Cycle of RGO Towards Glucose Detection 2023 Proceedings - 2023 IEEE Regional Symposium on Micro and Nanoelectronics, RSM 2023 10.1109/RSM59033.2023.10327336 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85179852138&doi=10.1109%2fRSM59033.2023.10327336&partnerID=40&md5=7a63d024e935772262cbb4ef9dbd0de6 The author report on the synthesis of reduced graphene oxide (RGO) using electrodeposition method on screen printed gold electrode (SPGE). The RGO were deposited on the screen-printed gold electrode (SPGE) using cyclic voltammetry technique with different cycles of 3, 5 and 7 of voltage range from-1.35V to-2.0V voltage applied. The surface morphology of RGO was being characterized using field-emission scanning electron microscopy (FESEM) and Raman spectroscopy. The intensity ratio of Raman spectra was being calculated in order to investigate the amount of disordered phase for each cycle. The cyclic voltammetry (CV) analysis was used in the detection of glucose and the linear curve plot was obtained. The sensitivity for each electrode was calculated from the slope obtained from the linear obtained from each electrode. The increase in the number of cycles increase the sensitivity of the sensor. The highest sensitivity in the detection of glucose concentration (1mM-10mM) was discovered from the RGO 7 cycles of electrodeposition. © 2023 IEEE. Institute of Electrical and Electronics Engineers Inc. English Conference paper |
author |
Ilias M.H.; Khairudin N.; Zoolfakar A.S.; Zolkapli M.; Zain Z.M.; Fitrah Abu Bakar N.; Rani R.A.; Manut A. |
spellingShingle |
Ilias M.H.; Khairudin N.; Zoolfakar A.S.; Zolkapli M.; Zain Z.M.; Fitrah Abu Bakar N.; Rani R.A.; Manut A. Effect of the Electrodeposition Cycle of RGO Towards Glucose Detection |
author_facet |
Ilias M.H.; Khairudin N.; Zoolfakar A.S.; Zolkapli M.; Zain Z.M.; Fitrah Abu Bakar N.; Rani R.A.; Manut A. |
author_sort |
Ilias M.H.; Khairudin N.; Zoolfakar A.S.; Zolkapli M.; Zain Z.M.; Fitrah Abu Bakar N.; Rani R.A.; Manut A. |
title |
Effect of the Electrodeposition Cycle of RGO Towards Glucose Detection |
title_short |
Effect of the Electrodeposition Cycle of RGO Towards Glucose Detection |
title_full |
Effect of the Electrodeposition Cycle of RGO Towards Glucose Detection |
title_fullStr |
Effect of the Electrodeposition Cycle of RGO Towards Glucose Detection |
title_full_unstemmed |
Effect of the Electrodeposition Cycle of RGO Towards Glucose Detection |
title_sort |
Effect of the Electrodeposition Cycle of RGO Towards Glucose Detection |
publishDate |
2023 |
container_title |
Proceedings - 2023 IEEE Regional Symposium on Micro and Nanoelectronics, RSM 2023 |
container_volume |
|
container_issue |
|
doi_str_mv |
10.1109/RSM59033.2023.10327336 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85179852138&doi=10.1109%2fRSM59033.2023.10327336&partnerID=40&md5=7a63d024e935772262cbb4ef9dbd0de6 |
description |
The author report on the synthesis of reduced graphene oxide (RGO) using electrodeposition method on screen printed gold electrode (SPGE). The RGO were deposited on the screen-printed gold electrode (SPGE) using cyclic voltammetry technique with different cycles of 3, 5 and 7 of voltage range from-1.35V to-2.0V voltage applied. The surface morphology of RGO was being characterized using field-emission scanning electron microscopy (FESEM) and Raman spectroscopy. The intensity ratio of Raman spectra was being calculated in order to investigate the amount of disordered phase for each cycle. The cyclic voltammetry (CV) analysis was used in the detection of glucose and the linear curve plot was obtained. The sensitivity for each electrode was calculated from the slope obtained from the linear obtained from each electrode. The increase in the number of cycles increase the sensitivity of the sensor. The highest sensitivity in the detection of glucose concentration (1mM-10mM) was discovered from the RGO 7 cycles of electrodeposition. © 2023 IEEE. |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
issn |
|
language |
English |
format |
Conference paper |
accesstype |
|
record_format |
scopus |
collection |
Scopus |
_version_ |
1809677587806420992 |