Effect of the Electrodeposition Cycle of RGO Towards Glucose Detection

The author report on the synthesis of reduced graphene oxide (RGO) using electrodeposition method on screen printed gold electrode (SPGE). The RGO were deposited on the screen-printed gold electrode (SPGE) using cyclic voltammetry technique with different cycles of 3, 5 and 7 of voltage range from-1...

Full description

Bibliographic Details
Published in:Proceedings - 2023 IEEE Regional Symposium on Micro and Nanoelectronics, RSM 2023
Main Author: Ilias M.H.; Khairudin N.; Zoolfakar A.S.; Zolkapli M.; Zain Z.M.; Fitrah Abu Bakar N.; Rani R.A.; Manut A.
Format: Conference paper
Language:English
Published: Institute of Electrical and Electronics Engineers Inc. 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85179852138&doi=10.1109%2fRSM59033.2023.10327336&partnerID=40&md5=7a63d024e935772262cbb4ef9dbd0de6
id 2-s2.0-85179852138
spelling 2-s2.0-85179852138
Ilias M.H.; Khairudin N.; Zoolfakar A.S.; Zolkapli M.; Zain Z.M.; Fitrah Abu Bakar N.; Rani R.A.; Manut A.
Effect of the Electrodeposition Cycle of RGO Towards Glucose Detection
2023
Proceedings - 2023 IEEE Regional Symposium on Micro and Nanoelectronics, RSM 2023


10.1109/RSM59033.2023.10327336
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85179852138&doi=10.1109%2fRSM59033.2023.10327336&partnerID=40&md5=7a63d024e935772262cbb4ef9dbd0de6
The author report on the synthesis of reduced graphene oxide (RGO) using electrodeposition method on screen printed gold electrode (SPGE). The RGO were deposited on the screen-printed gold electrode (SPGE) using cyclic voltammetry technique with different cycles of 3, 5 and 7 of voltage range from-1.35V to-2.0V voltage applied. The surface morphology of RGO was being characterized using field-emission scanning electron microscopy (FESEM) and Raman spectroscopy. The intensity ratio of Raman spectra was being calculated in order to investigate the amount of disordered phase for each cycle. The cyclic voltammetry (CV) analysis was used in the detection of glucose and the linear curve plot was obtained. The sensitivity for each electrode was calculated from the slope obtained from the linear obtained from each electrode. The increase in the number of cycles increase the sensitivity of the sensor. The highest sensitivity in the detection of glucose concentration (1mM-10mM) was discovered from the RGO 7 cycles of electrodeposition. © 2023 IEEE.
Institute of Electrical and Electronics Engineers Inc.

English
Conference paper

author Ilias M.H.; Khairudin N.; Zoolfakar A.S.; Zolkapli M.; Zain Z.M.; Fitrah Abu Bakar N.; Rani R.A.; Manut A.
spellingShingle Ilias M.H.; Khairudin N.; Zoolfakar A.S.; Zolkapli M.; Zain Z.M.; Fitrah Abu Bakar N.; Rani R.A.; Manut A.
Effect of the Electrodeposition Cycle of RGO Towards Glucose Detection
author_facet Ilias M.H.; Khairudin N.; Zoolfakar A.S.; Zolkapli M.; Zain Z.M.; Fitrah Abu Bakar N.; Rani R.A.; Manut A.
author_sort Ilias M.H.; Khairudin N.; Zoolfakar A.S.; Zolkapli M.; Zain Z.M.; Fitrah Abu Bakar N.; Rani R.A.; Manut A.
title Effect of the Electrodeposition Cycle of RGO Towards Glucose Detection
title_short Effect of the Electrodeposition Cycle of RGO Towards Glucose Detection
title_full Effect of the Electrodeposition Cycle of RGO Towards Glucose Detection
title_fullStr Effect of the Electrodeposition Cycle of RGO Towards Glucose Detection
title_full_unstemmed Effect of the Electrodeposition Cycle of RGO Towards Glucose Detection
title_sort Effect of the Electrodeposition Cycle of RGO Towards Glucose Detection
publishDate 2023
container_title Proceedings - 2023 IEEE Regional Symposium on Micro and Nanoelectronics, RSM 2023
container_volume
container_issue
doi_str_mv 10.1109/RSM59033.2023.10327336
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85179852138&doi=10.1109%2fRSM59033.2023.10327336&partnerID=40&md5=7a63d024e935772262cbb4ef9dbd0de6
description The author report on the synthesis of reduced graphene oxide (RGO) using electrodeposition method on screen printed gold electrode (SPGE). The RGO were deposited on the screen-printed gold electrode (SPGE) using cyclic voltammetry technique with different cycles of 3, 5 and 7 of voltage range from-1.35V to-2.0V voltage applied. The surface morphology of RGO was being characterized using field-emission scanning electron microscopy (FESEM) and Raman spectroscopy. The intensity ratio of Raman spectra was being calculated in order to investigate the amount of disordered phase for each cycle. The cyclic voltammetry (CV) analysis was used in the detection of glucose and the linear curve plot was obtained. The sensitivity for each electrode was calculated from the slope obtained from the linear obtained from each electrode. The increase in the number of cycles increase the sensitivity of the sensor. The highest sensitivity in the detection of glucose concentration (1mM-10mM) was discovered from the RGO 7 cycles of electrodeposition. © 2023 IEEE.
publisher Institute of Electrical and Electronics Engineers Inc.
issn
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1809677587806420992