Clinical Usefulness of Abbreviated MRI Protocol in Breast Cancer Detection

Background: The use of breast MRI for screening has increased over the past decade, mostly in women with a high risk of breast cancer. Abbreviated breast MRI (AB-MR) is introduced to make MRI a more accessible screening modality. AB-MR decreases scanning and reporting time and the overall cost of MR...

Full description

Bibliographic Details
Published in:Current Medical Imaging
Main Author: Hamid M.T.R.; Loi K.S.; Chan W.Y.; Mumin N.A.; Hamid S.A.; Rozalli F.I.; Rahmat K.
Format: Article
Language:English
Published: Bentham Science Publishers 2024
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85178364749&doi=10.2174%2f1573405620666230829150218&partnerID=40&md5=c287e649be1c18a3b6c099299d83d579
id 2-s2.0-85178364749
spelling 2-s2.0-85178364749
Hamid M.T.R.; Loi K.S.; Chan W.Y.; Mumin N.A.; Hamid S.A.; Rozalli F.I.; Rahmat K.
Clinical Usefulness of Abbreviated MRI Protocol in Breast Cancer Detection
2024
Current Medical Imaging
20

10.2174/1573405620666230829150218
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85178364749&doi=10.2174%2f1573405620666230829150218&partnerID=40&md5=c287e649be1c18a3b6c099299d83d579
Background: The use of breast MRI for screening has increased over the past decade, mostly in women with a high risk of breast cancer. Abbreviated breast MRI (AB-MR) is introduced to make MRI a more accessible screening modality. AB-MR decreases scanning and reporting time and the overall cost of MRI. Objective: This study aims to evaluate the diagnostic efficacy of abbreviated MRI protocol in detecting breast cancer in screening and diagnostic populations, using histopathology as the reference standard. Materials and Methods: This is a single-centre retrospective cross-sectional study of 134 patients with 198 histologically proven breast lesions who underwent full diagnostic protocol contrast-enhanced breast MRI (FDP-MR) at the University Malaya Medical Centre (UMMC) from 1st January 2018 to 31st December 2019. AB-MR was pre-determined and evaluated with regard to the potential to detect and exclude malignancy from 3 readers of varying radiological experiences. The sensitivity of both AB-MR and FDP-MR were compared using the McNemar test, where both protocols' diagnostic performances were assessed via the receiver operating characteristic (ROC) curve. Inter-observer agreement was analysed using Fleiss Kappa. Results: There were 134 patients with 198 lesions. The average age was 50.9 years old (range 27 – 80). A total of 121 (90%) MRIs were performed for diagnostic purposes. Screening accounted for 9.4% of the cases, 55.6% (n=110) lesions were benign, and 44.4% (n=88) were malignant. The commonest benign and malignant lesions were fibrocystic change (27.3%) and invasive ductal carcinoma (78.4%). The mean sensitivity, specificity, positive predictive value, and negative predictive value for AB-MR were 0.96, 0.57, 0.68 and 0.94, respectively. Both AB-MR and FDP-MR showed excellent diagnostic performance with AUC of 0.88 and 0.96, respectively. The general inter-observer agreement of all three readers for AB-MR was substantial (k=0.69), with fair agreement demonstrated between AB-MR and FDP-MR (k=0.36). Conclusion: The study shows no evidence that the diagnostic efficacy of AB-MR is inferior to FDP-MR. AB-MR, with high sensitivity, has proven its capability in cancer detection and exclusion, especially for biologically aggressive cancers. © 2024 The Author(s). Published by Bentham Science Publisher.
Bentham Science Publishers
15734056
English
Article
All Open Access; Hybrid Gold Open Access
author Hamid M.T.R.; Loi K.S.; Chan W.Y.; Mumin N.A.; Hamid S.A.; Rozalli F.I.; Rahmat K.
spellingShingle Hamid M.T.R.; Loi K.S.; Chan W.Y.; Mumin N.A.; Hamid S.A.; Rozalli F.I.; Rahmat K.
Clinical Usefulness of Abbreviated MRI Protocol in Breast Cancer Detection
author_facet Hamid M.T.R.; Loi K.S.; Chan W.Y.; Mumin N.A.; Hamid S.A.; Rozalli F.I.; Rahmat K.
author_sort Hamid M.T.R.; Loi K.S.; Chan W.Y.; Mumin N.A.; Hamid S.A.; Rozalli F.I.; Rahmat K.
title Clinical Usefulness of Abbreviated MRI Protocol in Breast Cancer Detection
title_short Clinical Usefulness of Abbreviated MRI Protocol in Breast Cancer Detection
title_full Clinical Usefulness of Abbreviated MRI Protocol in Breast Cancer Detection
title_fullStr Clinical Usefulness of Abbreviated MRI Protocol in Breast Cancer Detection
title_full_unstemmed Clinical Usefulness of Abbreviated MRI Protocol in Breast Cancer Detection
title_sort Clinical Usefulness of Abbreviated MRI Protocol in Breast Cancer Detection
publishDate 2024
container_title Current Medical Imaging
container_volume 20
container_issue
doi_str_mv 10.2174/1573405620666230829150218
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85178364749&doi=10.2174%2f1573405620666230829150218&partnerID=40&md5=c287e649be1c18a3b6c099299d83d579
description Background: The use of breast MRI for screening has increased over the past decade, mostly in women with a high risk of breast cancer. Abbreviated breast MRI (AB-MR) is introduced to make MRI a more accessible screening modality. AB-MR decreases scanning and reporting time and the overall cost of MRI. Objective: This study aims to evaluate the diagnostic efficacy of abbreviated MRI protocol in detecting breast cancer in screening and diagnostic populations, using histopathology as the reference standard. Materials and Methods: This is a single-centre retrospective cross-sectional study of 134 patients with 198 histologically proven breast lesions who underwent full diagnostic protocol contrast-enhanced breast MRI (FDP-MR) at the University Malaya Medical Centre (UMMC) from 1st January 2018 to 31st December 2019. AB-MR was pre-determined and evaluated with regard to the potential to detect and exclude malignancy from 3 readers of varying radiological experiences. The sensitivity of both AB-MR and FDP-MR were compared using the McNemar test, where both protocols' diagnostic performances were assessed via the receiver operating characteristic (ROC) curve. Inter-observer agreement was analysed using Fleiss Kappa. Results: There were 134 patients with 198 lesions. The average age was 50.9 years old (range 27 – 80). A total of 121 (90%) MRIs were performed for diagnostic purposes. Screening accounted for 9.4% of the cases, 55.6% (n=110) lesions were benign, and 44.4% (n=88) were malignant. The commonest benign and malignant lesions were fibrocystic change (27.3%) and invasive ductal carcinoma (78.4%). The mean sensitivity, specificity, positive predictive value, and negative predictive value for AB-MR were 0.96, 0.57, 0.68 and 0.94, respectively. Both AB-MR and FDP-MR showed excellent diagnostic performance with AUC of 0.88 and 0.96, respectively. The general inter-observer agreement of all three readers for AB-MR was substantial (k=0.69), with fair agreement demonstrated between AB-MR and FDP-MR (k=0.36). Conclusion: The study shows no evidence that the diagnostic efficacy of AB-MR is inferior to FDP-MR. AB-MR, with high sensitivity, has proven its capability in cancer detection and exclusion, especially for biologically aggressive cancers. © 2024 The Author(s). Published by Bentham Science Publisher.
publisher Bentham Science Publishers
issn 15734056
language English
format Article
accesstype All Open Access; Hybrid Gold Open Access
record_format scopus
collection Scopus
_version_ 1809678154763075584