Comparison between ultrasound and radiography for greenstick fracture with various angulations on pediatric distal radius: Phantom study

This study aims to compare the diagnostic accuracy of the ultrasound and radiography examinations in detecting the greenstick fracture with different angulations on pediatric distal radius using phantoms. Ten phantoms consisting of chicken leg bones and gelatin were prepared to represent the pediatr...

Full description

Bibliographic Details
Published in:AIP Conference Proceedings
Main Author: Noor N.A.M.; Supar R.; Yamin L.S.M.
Format: Conference paper
Language:English
Published: American Institute of Physics Inc. 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85176805709&doi=10.1063%2f5.0164529&partnerID=40&md5=2ed6a821a3ddd68674da7ed246d6dd64
id 2-s2.0-85176805709
spelling 2-s2.0-85176805709
Noor N.A.M.; Supar R.; Yamin L.S.M.
Comparison between ultrasound and radiography for greenstick fracture with various angulations on pediatric distal radius: Phantom study
2023
AIP Conference Proceedings
2827
1
10.1063/5.0164529
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85176805709&doi=10.1063%2f5.0164529&partnerID=40&md5=2ed6a821a3ddd68674da7ed246d6dd64
This study aims to compare the diagnostic accuracy of the ultrasound and radiography examinations in detecting the greenstick fracture with different angulations on pediatric distal radius using phantoms. Ten phantoms consisting of chicken leg bones and gelatin were prepared to represent the pediatric distal radius. There were two sets of phantoms, each containing two normal chicken leg bones and three chicken leg bones with different angulations of greenstick fracture at 10°, 20° and 30°. Three emergency physicians then evaluated all phantoms through ultrasound and radiographic images to diagnose the presence of greenstick fractures and determine the angulations if any. Based on the result, ultrasound has a high specificity,100% and low sensitivity, 55.6% with a positive predictive value, 100% and a negative predictive value, 60%, while radiography has low specificity, 50.0% and sensitivity, 44.4%, with a positive predictive value, 50% and negative predictive value, 37%. From this study, ultrasound is more effective in detecting greenstick fracture with different angulations on the distal radius as compared to radiography. © 2023 Author(s).
American Institute of Physics Inc.
0094243X
English
Conference paper

author Noor N.A.M.; Supar R.; Yamin L.S.M.
spellingShingle Noor N.A.M.; Supar R.; Yamin L.S.M.
Comparison between ultrasound and radiography for greenstick fracture with various angulations on pediatric distal radius: Phantom study
author_facet Noor N.A.M.; Supar R.; Yamin L.S.M.
author_sort Noor N.A.M.; Supar R.; Yamin L.S.M.
title Comparison between ultrasound and radiography for greenstick fracture with various angulations on pediatric distal radius: Phantom study
title_short Comparison between ultrasound and radiography for greenstick fracture with various angulations on pediatric distal radius: Phantom study
title_full Comparison between ultrasound and radiography for greenstick fracture with various angulations on pediatric distal radius: Phantom study
title_fullStr Comparison between ultrasound and radiography for greenstick fracture with various angulations on pediatric distal radius: Phantom study
title_full_unstemmed Comparison between ultrasound and radiography for greenstick fracture with various angulations on pediatric distal radius: Phantom study
title_sort Comparison between ultrasound and radiography for greenstick fracture with various angulations on pediatric distal radius: Phantom study
publishDate 2023
container_title AIP Conference Proceedings
container_volume 2827
container_issue 1
doi_str_mv 10.1063/5.0164529
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85176805709&doi=10.1063%2f5.0164529&partnerID=40&md5=2ed6a821a3ddd68674da7ed246d6dd64
description This study aims to compare the diagnostic accuracy of the ultrasound and radiography examinations in detecting the greenstick fracture with different angulations on pediatric distal radius using phantoms. Ten phantoms consisting of chicken leg bones and gelatin were prepared to represent the pediatric distal radius. There were two sets of phantoms, each containing two normal chicken leg bones and three chicken leg bones with different angulations of greenstick fracture at 10°, 20° and 30°. Three emergency physicians then evaluated all phantoms through ultrasound and radiographic images to diagnose the presence of greenstick fractures and determine the angulations if any. Based on the result, ultrasound has a high specificity,100% and low sensitivity, 55.6% with a positive predictive value, 100% and a negative predictive value, 60%, while radiography has low specificity, 50.0% and sensitivity, 44.4%, with a positive predictive value, 50% and negative predictive value, 37%. From this study, ultrasound is more effective in detecting greenstick fracture with different angulations on the distal radius as compared to radiography. © 2023 Author(s).
publisher American Institute of Physics Inc.
issn 0094243X
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1809677581229752320