Indoor Environmental Quality in Micro & Nanoelectronics Laboratories at IMEN, Research Complex, UKM

The National University of Malaysia's Micro and Nanoelectronics laboratories were examined to ascertain their comfort levels. Eight laboratories were chosen as the study locations. This study aims to assess the interior air quality at six locations by measuring CO2, formaldehyde CHOH, total vol...

Full description

Bibliographic Details
Published in:Journal of Advanced Research in Applied Sciences and Engineering Technology
Main Author: Hosnon M.H.; Sulong N.A.; Ehsan A.A.; Kharuddin K.N.M.
Format: Article
Language:English
Published: Penerbit Akademia Baru 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85174609877&doi=10.37934%2faraset.32.3.342354&partnerID=40&md5=208daf7d85e21acffd830e818255956e
id 2-s2.0-85174609877
spelling 2-s2.0-85174609877
Hosnon M.H.; Sulong N.A.; Ehsan A.A.; Kharuddin K.N.M.
Indoor Environmental Quality in Micro & Nanoelectronics Laboratories at IMEN, Research Complex, UKM
2023
Journal of Advanced Research in Applied Sciences and Engineering Technology
32
3
10.37934/araset.32.3.342354
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85174609877&doi=10.37934%2faraset.32.3.342354&partnerID=40&md5=208daf7d85e21acffd830e818255956e
The National University of Malaysia's Micro and Nanoelectronics laboratories were examined to ascertain their comfort levels. Eight laboratories were chosen as the study locations. This study aims to assess the interior air quality at six locations by measuring CO2, formaldehyde CHOH, total volatile organic compound TVOC, PM2.5, indoor temperature, and relative humidity. The thermal comfort evaluation for labs 1, 2, 3, 4, 5, and 7 is between 20.45 and 22.47 °C, which is below the range of DOSH and Ashrae. While the average readings in laboratories 6 and 8 are within the limits allowed at 23,21 °C and 23,75 °C, respectively. Five laboratories were exceeding the upper limit of RH (30–60%) but only three laboratories were still within the maximum level mentioned by the Ashrae standard. RH exceeded the ICOP limit (60%) at 70.3%, 63.7%, 75.4%, 60.6%, 62.8% and 65.5%, at Lab 1, 2,3,6,7 and 8, respectively, whereas temperature exceeded it (22.5-26 °C) at 20.45, 22.2, 21.9, 22.43, 21.58 and 22.47 at Lab 1, 2, 3, 4, 5, 7 and 8, respectively. While the average air velocities for all laboratories are 0.17, 0.13, 0.10, 0.16, 0.12, 0.14, 0.15 and 0.09 ms-1, respectively. All the data that has been measured is found to be below the maximum level as recommended by the ASHRAE Standard 55 (2004) of 0.25 ms-1. The indoor air contaminants (CO, CHOH, TVOC, PM2.5, and PM10) met the standard level of ICOP and DOSH except for CHOH approaches ICOP (0.1ppm) at 0.1 and 0.09, at Point 9 and Point 10 for laboratory 3 compared to other laboratories where the concentration obtained is lower. The highest laboratories average concentration of PM2.5 was 13 µg/m3 determined in Lab 3, which was the most actively utilized one because the research activity in this laboratory was working more intensively than the others. As in the study of PM2.5, the highest average PM10 concentration was evaluated in Lab 3 as 36 µg/m3. Based on observations and studies, we find that fresh outdoor air with a complete and good purifier/filter should be used to reduce the concentration of indoor pollutants. © 2023, Penerbit Akademia Baru. All rights reserved.
Penerbit Akademia Baru
24621943
English
Article
All Open Access; Hybrid Gold Open Access
author Hosnon M.H.; Sulong N.A.; Ehsan A.A.; Kharuddin K.N.M.
spellingShingle Hosnon M.H.; Sulong N.A.; Ehsan A.A.; Kharuddin K.N.M.
Indoor Environmental Quality in Micro & Nanoelectronics Laboratories at IMEN, Research Complex, UKM
author_facet Hosnon M.H.; Sulong N.A.; Ehsan A.A.; Kharuddin K.N.M.
author_sort Hosnon M.H.; Sulong N.A.; Ehsan A.A.; Kharuddin K.N.M.
title Indoor Environmental Quality in Micro & Nanoelectronics Laboratories at IMEN, Research Complex, UKM
title_short Indoor Environmental Quality in Micro & Nanoelectronics Laboratories at IMEN, Research Complex, UKM
title_full Indoor Environmental Quality in Micro & Nanoelectronics Laboratories at IMEN, Research Complex, UKM
title_fullStr Indoor Environmental Quality in Micro & Nanoelectronics Laboratories at IMEN, Research Complex, UKM
title_full_unstemmed Indoor Environmental Quality in Micro & Nanoelectronics Laboratories at IMEN, Research Complex, UKM
title_sort Indoor Environmental Quality in Micro & Nanoelectronics Laboratories at IMEN, Research Complex, UKM
publishDate 2023
container_title Journal of Advanced Research in Applied Sciences and Engineering Technology
container_volume 32
container_issue 3
doi_str_mv 10.37934/araset.32.3.342354
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85174609877&doi=10.37934%2faraset.32.3.342354&partnerID=40&md5=208daf7d85e21acffd830e818255956e
description The National University of Malaysia's Micro and Nanoelectronics laboratories were examined to ascertain their comfort levels. Eight laboratories were chosen as the study locations. This study aims to assess the interior air quality at six locations by measuring CO2, formaldehyde CHOH, total volatile organic compound TVOC, PM2.5, indoor temperature, and relative humidity. The thermal comfort evaluation for labs 1, 2, 3, 4, 5, and 7 is between 20.45 and 22.47 °C, which is below the range of DOSH and Ashrae. While the average readings in laboratories 6 and 8 are within the limits allowed at 23,21 °C and 23,75 °C, respectively. Five laboratories were exceeding the upper limit of RH (30–60%) but only three laboratories were still within the maximum level mentioned by the Ashrae standard. RH exceeded the ICOP limit (60%) at 70.3%, 63.7%, 75.4%, 60.6%, 62.8% and 65.5%, at Lab 1, 2,3,6,7 and 8, respectively, whereas temperature exceeded it (22.5-26 °C) at 20.45, 22.2, 21.9, 22.43, 21.58 and 22.47 at Lab 1, 2, 3, 4, 5, 7 and 8, respectively. While the average air velocities for all laboratories are 0.17, 0.13, 0.10, 0.16, 0.12, 0.14, 0.15 and 0.09 ms-1, respectively. All the data that has been measured is found to be below the maximum level as recommended by the ASHRAE Standard 55 (2004) of 0.25 ms-1. The indoor air contaminants (CO, CHOH, TVOC, PM2.5, and PM10) met the standard level of ICOP and DOSH except for CHOH approaches ICOP (0.1ppm) at 0.1 and 0.09, at Point 9 and Point 10 for laboratory 3 compared to other laboratories where the concentration obtained is lower. The highest laboratories average concentration of PM2.5 was 13 µg/m3 determined in Lab 3, which was the most actively utilized one because the research activity in this laboratory was working more intensively than the others. As in the study of PM2.5, the highest average PM10 concentration was evaluated in Lab 3 as 36 µg/m3. Based on observations and studies, we find that fresh outdoor air with a complete and good purifier/filter should be used to reduce the concentration of indoor pollutants. © 2023, Penerbit Akademia Baru. All rights reserved.
publisher Penerbit Akademia Baru
issn 24621943
language English
format Article
accesstype All Open Access; Hybrid Gold Open Access
record_format scopus
collection Scopus
_version_ 1809678016083656704