Comparative Study between Horn-Schunk and Lucas Kenade Optical Flow Method for Lung Lesion Identification in Computed Tomography Images

This study compares the Horn-schunk and Lucas Kenade optical flow methods for lung lesion identification in computed tomography (CT) images. Mostly, the detected lesions were based only on a single CT image. However, detecting lesions from a single image does not align with the Radiologist's pr...

Full description

Bibliographic Details
Published in:Proceedings - 13th IEEE International Conference on Control System, Computing and Engineering, ICCSCE 2023
Main Author: Abdullah M.F.; Sulaiman S.N.B.; Osman M.K.; Karim N.K.A.; Ani A.I.C.; Damit D.S.A.
Format: Conference paper
Language:English
Published: Institute of Electrical and Electronics Engineers Inc. 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85172864792&doi=10.1109%2fICCSCE58721.2023.10237099&partnerID=40&md5=e99936996a4d91ca88cabec388ead629
id 2-s2.0-85172864792
spelling 2-s2.0-85172864792
Abdullah M.F.; Sulaiman S.N.B.; Osman M.K.; Karim N.K.A.; Ani A.I.C.; Damit D.S.A.
Comparative Study between Horn-Schunk and Lucas Kenade Optical Flow Method for Lung Lesion Identification in Computed Tomography Images
2023
Proceedings - 13th IEEE International Conference on Control System, Computing and Engineering, ICCSCE 2023


10.1109/ICCSCE58721.2023.10237099
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85172864792&doi=10.1109%2fICCSCE58721.2023.10237099&partnerID=40&md5=e99936996a4d91ca88cabec388ead629
This study compares the Horn-schunk and Lucas Kenade optical flow methods for lung lesion identification in computed tomography (CT) images. Mostly, the detected lesions were based only on a single CT image. However, detecting lesions from a single image does not align with the Radiologist's practice based on sequential images. Therefore, there is a need to consider the before-and-after images for identifying the moving object in the lung corresponding to the lesions' detection. Hence, this project aims to identify the lung lesion using two optical flow methods. The method that analyses pair of images called the optical flow method was chosen since the object stores the direction and speed of a moving object from one image, or video frame to another. The optical flow-based approach uses a pair of frames as data to measure optical flow based on four different mode selections. A new method has been proposed to find the possible images of lung lesions based on the standard deviation from the threshold value. As the image pair selected, the Horn-Schunck and Lukas Kenade optical flow method was picked in this study. Based on two optical flow approaches, Horn-Schunk was the most efficient way of locating lesions using mode 0 with a standard deviation of 0.99%. The finding was revealed that the threshold value based on the length of the optical flow vector gives a significant output for predicting the lesions and non-lesion CT images range. © 2023 IEEE.
Institute of Electrical and Electronics Engineers Inc.

English
Conference paper

author Abdullah M.F.; Sulaiman S.N.B.; Osman M.K.; Karim N.K.A.; Ani A.I.C.; Damit D.S.A.
spellingShingle Abdullah M.F.; Sulaiman S.N.B.; Osman M.K.; Karim N.K.A.; Ani A.I.C.; Damit D.S.A.
Comparative Study between Horn-Schunk and Lucas Kenade Optical Flow Method for Lung Lesion Identification in Computed Tomography Images
author_facet Abdullah M.F.; Sulaiman S.N.B.; Osman M.K.; Karim N.K.A.; Ani A.I.C.; Damit D.S.A.
author_sort Abdullah M.F.; Sulaiman S.N.B.; Osman M.K.; Karim N.K.A.; Ani A.I.C.; Damit D.S.A.
title Comparative Study between Horn-Schunk and Lucas Kenade Optical Flow Method for Lung Lesion Identification in Computed Tomography Images
title_short Comparative Study between Horn-Schunk and Lucas Kenade Optical Flow Method for Lung Lesion Identification in Computed Tomography Images
title_full Comparative Study between Horn-Schunk and Lucas Kenade Optical Flow Method for Lung Lesion Identification in Computed Tomography Images
title_fullStr Comparative Study between Horn-Schunk and Lucas Kenade Optical Flow Method for Lung Lesion Identification in Computed Tomography Images
title_full_unstemmed Comparative Study between Horn-Schunk and Lucas Kenade Optical Flow Method for Lung Lesion Identification in Computed Tomography Images
title_sort Comparative Study between Horn-Schunk and Lucas Kenade Optical Flow Method for Lung Lesion Identification in Computed Tomography Images
publishDate 2023
container_title Proceedings - 13th IEEE International Conference on Control System, Computing and Engineering, ICCSCE 2023
container_volume
container_issue
doi_str_mv 10.1109/ICCSCE58721.2023.10237099
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85172864792&doi=10.1109%2fICCSCE58721.2023.10237099&partnerID=40&md5=e99936996a4d91ca88cabec388ead629
description This study compares the Horn-schunk and Lucas Kenade optical flow methods for lung lesion identification in computed tomography (CT) images. Mostly, the detected lesions were based only on a single CT image. However, detecting lesions from a single image does not align with the Radiologist's practice based on sequential images. Therefore, there is a need to consider the before-and-after images for identifying the moving object in the lung corresponding to the lesions' detection. Hence, this project aims to identify the lung lesion using two optical flow methods. The method that analyses pair of images called the optical flow method was chosen since the object stores the direction and speed of a moving object from one image, or video frame to another. The optical flow-based approach uses a pair of frames as data to measure optical flow based on four different mode selections. A new method has been proposed to find the possible images of lung lesions based on the standard deviation from the threshold value. As the image pair selected, the Horn-Schunck and Lukas Kenade optical flow method was picked in this study. Based on two optical flow approaches, Horn-Schunk was the most efficient way of locating lesions using mode 0 with a standard deviation of 0.99%. The finding was revealed that the threshold value based on the length of the optical flow vector gives a significant output for predicting the lesions and non-lesion CT images range. © 2023 IEEE.
publisher Institute of Electrical and Electronics Engineers Inc.
issn
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1809677889541505024