A Model for Verification of High Neutral-to-Ground Voltage (NTGV) in Educational Buildings
There are various factors that can cause the rise of Neutral-To-Ground Voltage (NTGV) in an educational building. However, based on the pattern of the recorded NTGV, it is difficult to identify the possible factors that contributed to the event. This situation could lead to the wrong decisions to mi...
Published in: | International Review of Electrical Engineering |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Published: |
Praise Worthy Prize S.r.l
2023
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85171630335&doi=10.15866%2firee.v18i3.23175&partnerID=40&md5=d3554804c2b6772f7d220c6d35e39c0b |
id |
2-s2.0-85171630335 |
---|---|
spelling |
2-s2.0-85171630335 Mahadan M.E.; Abidin A.F.; Mat Yusoh M.A.T.; Hairuddin M.A.; Mustapa R.F. A Model for Verification of High Neutral-to-Ground Voltage (NTGV) in Educational Buildings 2023 International Review of Electrical Engineering 18 3 10.15866/iree.v18i3.23175 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85171630335&doi=10.15866%2firee.v18i3.23175&partnerID=40&md5=d3554804c2b6772f7d220c6d35e39c0b There are various factors that can cause the rise of Neutral-To-Ground Voltage (NTGV) in an educational building. However, based on the pattern of the recorded NTGV, it is difficult to identify the possible factors that contributed to the event. This situation could lead to the wrong decisions to mitigate the corresponding problem. Thus, the main objective of this paper is to verify the high NTGV events based on a model of the educational building’s three-phase four-wire system. In this study, the developed educational building electrical network model is integrated with the model for events in a MATLAB/SIMULINK environment. According to the findings, high NTGV events in the building were caused by lightning and ground fault activities. This shows that the model is accurate and suitable to be used for analysing the high NTGV events in an educational building if they are detected. © 2023 Praise Worthy Prize S.r.l. All rights reserved. Praise Worthy Prize S.r.l 18276660 English Article |
author |
Mahadan M.E.; Abidin A.F.; Mat Yusoh M.A.T.; Hairuddin M.A.; Mustapa R.F. |
spellingShingle |
Mahadan M.E.; Abidin A.F.; Mat Yusoh M.A.T.; Hairuddin M.A.; Mustapa R.F. A Model for Verification of High Neutral-to-Ground Voltage (NTGV) in Educational Buildings |
author_facet |
Mahadan M.E.; Abidin A.F.; Mat Yusoh M.A.T.; Hairuddin M.A.; Mustapa R.F. |
author_sort |
Mahadan M.E.; Abidin A.F.; Mat Yusoh M.A.T.; Hairuddin M.A.; Mustapa R.F. |
title |
A Model for Verification of High Neutral-to-Ground Voltage (NTGV) in Educational Buildings |
title_short |
A Model for Verification of High Neutral-to-Ground Voltage (NTGV) in Educational Buildings |
title_full |
A Model for Verification of High Neutral-to-Ground Voltage (NTGV) in Educational Buildings |
title_fullStr |
A Model for Verification of High Neutral-to-Ground Voltage (NTGV) in Educational Buildings |
title_full_unstemmed |
A Model for Verification of High Neutral-to-Ground Voltage (NTGV) in Educational Buildings |
title_sort |
A Model for Verification of High Neutral-to-Ground Voltage (NTGV) in Educational Buildings |
publishDate |
2023 |
container_title |
International Review of Electrical Engineering |
container_volume |
18 |
container_issue |
3 |
doi_str_mv |
10.15866/iree.v18i3.23175 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85171630335&doi=10.15866%2firee.v18i3.23175&partnerID=40&md5=d3554804c2b6772f7d220c6d35e39c0b |
description |
There are various factors that can cause the rise of Neutral-To-Ground Voltage (NTGV) in an educational building. However, based on the pattern of the recorded NTGV, it is difficult to identify the possible factors that contributed to the event. This situation could lead to the wrong decisions to mitigate the corresponding problem. Thus, the main objective of this paper is to verify the high NTGV events based on a model of the educational building’s three-phase four-wire system. In this study, the developed educational building electrical network model is integrated with the model for events in a MATLAB/SIMULINK environment. According to the findings, high NTGV events in the building were caused by lightning and ground fault activities. This shows that the model is accurate and suitable to be used for analysing the high NTGV events in an educational building if they are detected. © 2023 Praise Worthy Prize S.r.l. All rights reserved. |