Examination on Acoustic Emission Partial Discharge Localization Error Rate in Oil in the Presence of Pressboard

This paper presents an examination on acoustic emission (AE) partial discharge (PD) signal characteristic in oil in the presence of pressboard. First, a test tank was fabricated whereby the PD was generated through needle-plane electrode configuration. Next, the pressboard was placed at the PD sourc...

Full description

Bibliographic Details
Published in:APL 2023 - 12th Asia-Pacific International Conference on Lightning
Main Author: Hashim A.H.M.; Ahmad N.D.; Azis N.; Jasni J.; Radzi M.A.M.; Kozako M.; Jamil M.K.M.
Format: Conference paper
Language:English
Published: Institute of Electrical and Electronics Engineers Inc. 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85166736179&doi=10.1109%2fAPL57308.2023.10182077&partnerID=40&md5=6db38be4625f3448fc49ee285b59b6c8
id 2-s2.0-85166736179
spelling 2-s2.0-85166736179
Hashim A.H.M.; Ahmad N.D.; Azis N.; Jasni J.; Radzi M.A.M.; Kozako M.; Jamil M.K.M.
Examination on Acoustic Emission Partial Discharge Localization Error Rate in Oil in the Presence of Pressboard
2023
APL 2023 - 12th Asia-Pacific International Conference on Lightning


10.1109/APL57308.2023.10182077
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85166736179&doi=10.1109%2fAPL57308.2023.10182077&partnerID=40&md5=6db38be4625f3448fc49ee285b59b6c8
This paper presents an examination on acoustic emission (AE) partial discharge (PD) signal characteristic in oil in the presence of pressboard. First, a test tank was fabricated whereby the PD was generated through needle-plane electrode configuration. Next, the pressboard was placed at the PD source. The electrical PD was measured through Impedance Matching Circuit (IMC) whereby the AE PD signal was measured using AE sensor. Based on the measured AE PD signal, the time of arrival (TOA), amplitude, duration, and distance between PD location and AE sensor was examined. Location error and root mean square error (RMSE) was used to evaluate the PD localization error rate. It is found that the presence of pressboard has an impact on PD localization location error rate and RMSE. © 2023 IEEE.
Institute of Electrical and Electronics Engineers Inc.

English
Conference paper

author Hashim A.H.M.; Ahmad N.D.; Azis N.; Jasni J.; Radzi M.A.M.; Kozako M.; Jamil M.K.M.
spellingShingle Hashim A.H.M.; Ahmad N.D.; Azis N.; Jasni J.; Radzi M.A.M.; Kozako M.; Jamil M.K.M.
Examination on Acoustic Emission Partial Discharge Localization Error Rate in Oil in the Presence of Pressboard
author_facet Hashim A.H.M.; Ahmad N.D.; Azis N.; Jasni J.; Radzi M.A.M.; Kozako M.; Jamil M.K.M.
author_sort Hashim A.H.M.; Ahmad N.D.; Azis N.; Jasni J.; Radzi M.A.M.; Kozako M.; Jamil M.K.M.
title Examination on Acoustic Emission Partial Discharge Localization Error Rate in Oil in the Presence of Pressboard
title_short Examination on Acoustic Emission Partial Discharge Localization Error Rate in Oil in the Presence of Pressboard
title_full Examination on Acoustic Emission Partial Discharge Localization Error Rate in Oil in the Presence of Pressboard
title_fullStr Examination on Acoustic Emission Partial Discharge Localization Error Rate in Oil in the Presence of Pressboard
title_full_unstemmed Examination on Acoustic Emission Partial Discharge Localization Error Rate in Oil in the Presence of Pressboard
title_sort Examination on Acoustic Emission Partial Discharge Localization Error Rate in Oil in the Presence of Pressboard
publishDate 2023
container_title APL 2023 - 12th Asia-Pacific International Conference on Lightning
container_volume
container_issue
doi_str_mv 10.1109/APL57308.2023.10182077
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85166736179&doi=10.1109%2fAPL57308.2023.10182077&partnerID=40&md5=6db38be4625f3448fc49ee285b59b6c8
description This paper presents an examination on acoustic emission (AE) partial discharge (PD) signal characteristic in oil in the presence of pressboard. First, a test tank was fabricated whereby the PD was generated through needle-plane electrode configuration. Next, the pressboard was placed at the PD source. The electrical PD was measured through Impedance Matching Circuit (IMC) whereby the AE PD signal was measured using AE sensor. Based on the measured AE PD signal, the time of arrival (TOA), amplitude, duration, and distance between PD location and AE sensor was examined. Location error and root mean square error (RMSE) was used to evaluate the PD localization error rate. It is found that the presence of pressboard has an impact on PD localization location error rate and RMSE. © 2023 IEEE.
publisher Institute of Electrical and Electronics Engineers Inc.
issn
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1809677589839609856