Behaviour of RC Columns Strengthened with Partial Carbon Fibre Reinforced Polymer (CFRP) Confinement

Recently, carbon fibre reinforced polymer (CFRP), particularly for strengthening RC columns, has been the chosen strengthening method. However, various approaches have been adopted to use CFRP as a strengthening material due to the higher expense of employing it. In this study, the behaviour of RC c...

Full description

Bibliographic Details
Published in:Lecture Notes in Civil Engineering
Main Author: Othman N.; Ahmad H.; Ismail R.; Zakwan F.A.A.; Dee G.L.; Wahid N.
Format: Conference paper
Language:English
Published: Springer Science and Business Media Deutschland GmbH 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85164270806&doi=10.1007%2f978-3-031-32511-3_85&partnerID=40&md5=797bfc10178a9a3c22e25f63403b45b2
id 2-s2.0-85164270806
spelling 2-s2.0-85164270806
Othman N.; Ahmad H.; Ismail R.; Zakwan F.A.A.; Dee G.L.; Wahid N.
Behaviour of RC Columns Strengthened with Partial Carbon Fibre Reinforced Polymer (CFRP) Confinement
2023
Lecture Notes in Civil Engineering
350 LNCE

10.1007/978-3-031-32511-3_85
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85164270806&doi=10.1007%2f978-3-031-32511-3_85&partnerID=40&md5=797bfc10178a9a3c22e25f63403b45b2
Recently, carbon fibre reinforced polymer (CFRP), particularly for strengthening RC columns, has been the chosen strengthening method. However, various approaches have been adopted to use CFRP as a strengthening material due to the higher expense of employing it. In this study, the behaviour of RC columns confined with one and two layers of CFRP strips were examined, and a comparison between confined and unconfined RC columns is conducted. Twelve RC column specimens with dimensions of 200 mm in diameter and 1000 mm in height were cast and tested under an axial load. In this study, the load-displacement, stress-strain, improvement in strength, and failure modes of the RC column specimens were discussed. This study revealed that, compared to an unconfined RC column, the strength of the RC column rose by 40% and 48%, respectively, with the confinement of one and two layers of CFRP strips. Existing mathematical model is used in an analytical investigation to compare and predict the experimental stress-strain RC column outcome. © 2023, The Author(s), under exclusive license to Springer Nature Switzerland AG.
Springer Science and Business Media Deutschland GmbH
23662557
English
Conference paper

author Othman N.; Ahmad H.; Ismail R.; Zakwan F.A.A.; Dee G.L.; Wahid N.
spellingShingle Othman N.; Ahmad H.; Ismail R.; Zakwan F.A.A.; Dee G.L.; Wahid N.
Behaviour of RC Columns Strengthened with Partial Carbon Fibre Reinforced Polymer (CFRP) Confinement
author_facet Othman N.; Ahmad H.; Ismail R.; Zakwan F.A.A.; Dee G.L.; Wahid N.
author_sort Othman N.; Ahmad H.; Ismail R.; Zakwan F.A.A.; Dee G.L.; Wahid N.
title Behaviour of RC Columns Strengthened with Partial Carbon Fibre Reinforced Polymer (CFRP) Confinement
title_short Behaviour of RC Columns Strengthened with Partial Carbon Fibre Reinforced Polymer (CFRP) Confinement
title_full Behaviour of RC Columns Strengthened with Partial Carbon Fibre Reinforced Polymer (CFRP) Confinement
title_fullStr Behaviour of RC Columns Strengthened with Partial Carbon Fibre Reinforced Polymer (CFRP) Confinement
title_full_unstemmed Behaviour of RC Columns Strengthened with Partial Carbon Fibre Reinforced Polymer (CFRP) Confinement
title_sort Behaviour of RC Columns Strengthened with Partial Carbon Fibre Reinforced Polymer (CFRP) Confinement
publishDate 2023
container_title Lecture Notes in Civil Engineering
container_volume 350 LNCE
container_issue
doi_str_mv 10.1007/978-3-031-32511-3_85
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85164270806&doi=10.1007%2f978-3-031-32511-3_85&partnerID=40&md5=797bfc10178a9a3c22e25f63403b45b2
description Recently, carbon fibre reinforced polymer (CFRP), particularly for strengthening RC columns, has been the chosen strengthening method. However, various approaches have been adopted to use CFRP as a strengthening material due to the higher expense of employing it. In this study, the behaviour of RC columns confined with one and two layers of CFRP strips were examined, and a comparison between confined and unconfined RC columns is conducted. Twelve RC column specimens with dimensions of 200 mm in diameter and 1000 mm in height were cast and tested under an axial load. In this study, the load-displacement, stress-strain, improvement in strength, and failure modes of the RC column specimens were discussed. This study revealed that, compared to an unconfined RC column, the strength of the RC column rose by 40% and 48%, respectively, with the confinement of one and two layers of CFRP strips. Existing mathematical model is used in an analytical investigation to compare and predict the experimental stress-strain RC column outcome. © 2023, The Author(s), under exclusive license to Springer Nature Switzerland AG.
publisher Springer Science and Business Media Deutschland GmbH
issn 23662557
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1809678021544640512