IN-SYRINGE DISPERSIVE SOLID PHASE MICROEXTRACTION FOR THE DETERMINATION OF ORGANOPHOSPHORUS PESTICIDE RESIDUES IN VEGETABLES; [(Pengestrakan Mikro Fasa Pepejal Secara Penyerakan dalam Picagari bagi Penentuan Sisa Racun Jenis Organofosforus dalam Sayur-Sayuran)]

In-syringe dispersive solid-phase microextraction with activated carbon as adsorbent was successfully developed to determine organophosphorus pesticide (OPP) residues in vegetable samples and the analytes were detected using gas chromatography-flame photometric detector (GC-FPD). Under optimized con...

Full description

Bibliographic Details
Published in:Malaysian Journal of Analytical Sciences
Main Author: Manap H.N.; Yunus F.B.M.; Zain N.N.M.; Yahaya N.; Surikumaran H.; Chandrasekaram K.; Sambasevam K.P.; Raoov M.
Format: Article
Language:English
Published: Malaysian Society of Analytical Sciences 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85164124215&partnerID=40&md5=d075a668f0cbc8a437a37b565d785034
id 2-s2.0-85164124215
spelling 2-s2.0-85164124215
Manap H.N.; Yunus F.B.M.; Zain N.N.M.; Yahaya N.; Surikumaran H.; Chandrasekaram K.; Sambasevam K.P.; Raoov M.
IN-SYRINGE DISPERSIVE SOLID PHASE MICROEXTRACTION FOR THE DETERMINATION OF ORGANOPHOSPHORUS PESTICIDE RESIDUES IN VEGETABLES; [(Pengestrakan Mikro Fasa Pepejal Secara Penyerakan dalam Picagari bagi Penentuan Sisa Racun Jenis Organofosforus dalam Sayur-Sayuran)]
2023
Malaysian Journal of Analytical Sciences
27
3

https://www.scopus.com/inward/record.uri?eid=2-s2.0-85164124215&partnerID=40&md5=d075a668f0cbc8a437a37b565d785034
In-syringe dispersive solid-phase microextraction with activated carbon as adsorbent was successfully developed to determine organophosphorus pesticide (OPP) residues in vegetable samples and the analytes were detected using gas chromatography-flame photometric detector (GC-FPD). Under optimized conditions (6 mg of activated carbon in 10 mL sample volume with 3 min extraction time and desorption with 300 µL of acetone), activated carbon was proven to be an effective adsorbent for the organophosphorus pesticide residues in vegetable samples with a satisfactory percentage recovery achieved from 81.46 to 108.93%. All the studied analytes showed good linearity in the range of 10 to 500 µg kg-1 and the correlation of determination (R2) was from 0.9962 to 0.9985. The LODs obtained were from 0.39 to 0.84 µg kg-1, and LOQs were from 1.18 to 2.56 µg kg-1. This method gives precision values for both intra-and inter-day within accepted variable limits (<15 % of RSD). The in-syringe dispersive solid-phase microextraction managed to eliminate the centrifugation process, reduce chemical consumption during extraction, and additionally speed up the extraction process, making it more efficient. This developed method can be applied to real samples such as vegetables and fruit juices as well as tap, river, or ground water analysis for the determination of OPPs. © 2023, Malaysian Society of Analytical Sciences. All rights reserved.
Malaysian Society of Analytical Sciences
13942506
English
Article

author Manap H.N.; Yunus F.B.M.; Zain N.N.M.; Yahaya N.; Surikumaran H.; Chandrasekaram K.; Sambasevam K.P.; Raoov M.
spellingShingle Manap H.N.; Yunus F.B.M.; Zain N.N.M.; Yahaya N.; Surikumaran H.; Chandrasekaram K.; Sambasevam K.P.; Raoov M.
IN-SYRINGE DISPERSIVE SOLID PHASE MICROEXTRACTION FOR THE DETERMINATION OF ORGANOPHOSPHORUS PESTICIDE RESIDUES IN VEGETABLES; [(Pengestrakan Mikro Fasa Pepejal Secara Penyerakan dalam Picagari bagi Penentuan Sisa Racun Jenis Organofosforus dalam Sayur-Sayuran)]
author_facet Manap H.N.; Yunus F.B.M.; Zain N.N.M.; Yahaya N.; Surikumaran H.; Chandrasekaram K.; Sambasevam K.P.; Raoov M.
author_sort Manap H.N.; Yunus F.B.M.; Zain N.N.M.; Yahaya N.; Surikumaran H.; Chandrasekaram K.; Sambasevam K.P.; Raoov M.
title IN-SYRINGE DISPERSIVE SOLID PHASE MICROEXTRACTION FOR THE DETERMINATION OF ORGANOPHOSPHORUS PESTICIDE RESIDUES IN VEGETABLES; [(Pengestrakan Mikro Fasa Pepejal Secara Penyerakan dalam Picagari bagi Penentuan Sisa Racun Jenis Organofosforus dalam Sayur-Sayuran)]
title_short IN-SYRINGE DISPERSIVE SOLID PHASE MICROEXTRACTION FOR THE DETERMINATION OF ORGANOPHOSPHORUS PESTICIDE RESIDUES IN VEGETABLES; [(Pengestrakan Mikro Fasa Pepejal Secara Penyerakan dalam Picagari bagi Penentuan Sisa Racun Jenis Organofosforus dalam Sayur-Sayuran)]
title_full IN-SYRINGE DISPERSIVE SOLID PHASE MICROEXTRACTION FOR THE DETERMINATION OF ORGANOPHOSPHORUS PESTICIDE RESIDUES IN VEGETABLES; [(Pengestrakan Mikro Fasa Pepejal Secara Penyerakan dalam Picagari bagi Penentuan Sisa Racun Jenis Organofosforus dalam Sayur-Sayuran)]
title_fullStr IN-SYRINGE DISPERSIVE SOLID PHASE MICROEXTRACTION FOR THE DETERMINATION OF ORGANOPHOSPHORUS PESTICIDE RESIDUES IN VEGETABLES; [(Pengestrakan Mikro Fasa Pepejal Secara Penyerakan dalam Picagari bagi Penentuan Sisa Racun Jenis Organofosforus dalam Sayur-Sayuran)]
title_full_unstemmed IN-SYRINGE DISPERSIVE SOLID PHASE MICROEXTRACTION FOR THE DETERMINATION OF ORGANOPHOSPHORUS PESTICIDE RESIDUES IN VEGETABLES; [(Pengestrakan Mikro Fasa Pepejal Secara Penyerakan dalam Picagari bagi Penentuan Sisa Racun Jenis Organofosforus dalam Sayur-Sayuran)]
title_sort IN-SYRINGE DISPERSIVE SOLID PHASE MICROEXTRACTION FOR THE DETERMINATION OF ORGANOPHOSPHORUS PESTICIDE RESIDUES IN VEGETABLES; [(Pengestrakan Mikro Fasa Pepejal Secara Penyerakan dalam Picagari bagi Penentuan Sisa Racun Jenis Organofosforus dalam Sayur-Sayuran)]
publishDate 2023
container_title Malaysian Journal of Analytical Sciences
container_volume 27
container_issue 3
doi_str_mv
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85164124215&partnerID=40&md5=d075a668f0cbc8a437a37b565d785034
description In-syringe dispersive solid-phase microextraction with activated carbon as adsorbent was successfully developed to determine organophosphorus pesticide (OPP) residues in vegetable samples and the analytes were detected using gas chromatography-flame photometric detector (GC-FPD). Under optimized conditions (6 mg of activated carbon in 10 mL sample volume with 3 min extraction time and desorption with 300 µL of acetone), activated carbon was proven to be an effective adsorbent for the organophosphorus pesticide residues in vegetable samples with a satisfactory percentage recovery achieved from 81.46 to 108.93%. All the studied analytes showed good linearity in the range of 10 to 500 µg kg-1 and the correlation of determination (R2) was from 0.9962 to 0.9985. The LODs obtained were from 0.39 to 0.84 µg kg-1, and LOQs were from 1.18 to 2.56 µg kg-1. This method gives precision values for both intra-and inter-day within accepted variable limits (<15 % of RSD). The in-syringe dispersive solid-phase microextraction managed to eliminate the centrifugation process, reduce chemical consumption during extraction, and additionally speed up the extraction process, making it more efficient. This developed method can be applied to real samples such as vegetables and fruit juices as well as tap, river, or ground water analysis for the determination of OPPs. © 2023, Malaysian Society of Analytical Sciences. All rights reserved.
publisher Malaysian Society of Analytical Sciences
issn 13942506
language English
format Article
accesstype
record_format scopus
collection Scopus
_version_ 1809677590846242816