Effect of the Water Condensation Rate with the Presence of Gas Condensate in the Wet Gas Pipeline
Pipelines are common medium to transfer hydrocarbons, but their integrity are compromised with the corrosion issues specifically in top of line corrosion (TLC) due to several influence factors such as water condensation. Water condensation occurs due to a significant variance in temperature outside...
Published in: | Key Engineering Materials |
---|---|
Main Author: | |
Format: | Book chapter |
Language: | English |
Published: |
Trans Tech Publications Ltd
2023
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85163694400&doi=10.4028%2fp-609529&partnerID=40&md5=51b849839819bfdcee8484c6c0d9223f |
id |
2-s2.0-85163694400 |
---|---|
spelling |
2-s2.0-85163694400 Husna H.J.; Wan Nurmi S.W.A.; Mohd Rizuan M.R.; Adli M.N.; Najmiddin Y. Effect of the Water Condensation Rate with the Presence of Gas Condensate in the Wet Gas Pipeline 2023 Key Engineering Materials 939 10.4028/p-609529 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85163694400&doi=10.4028%2fp-609529&partnerID=40&md5=51b849839819bfdcee8484c6c0d9223f Pipelines are common medium to transfer hydrocarbons, but their integrity are compromised with the corrosion issues specifically in top of line corrosion (TLC) due to several influence factors such as water condensation. Water condensation occurs due to a significant variance in temperature outside the pipeline and inside the pipeline as water condenses in the inner pipeline. Hence, this paper aims to study the water condensation rate (WCR) behaviour in the presence of gas condensate in wet gas pipelines. The objectives of the research are to determine the components of the gas condensate by characterizing the gas condensate using Gas Chromatography–Mass Spectrometry (GC-MS) and Fourier-Transform Infrared Spectroscopy (FTIR) equipment and later to determine the effect of gas condensate on water condensation rate by conducting 2 different experiments. The condition of TLC was imitated by using a customized TLC testing unit, whereby 2 sets of API 5L X65 carbon steel coupons were used. Meanwhile, the delta temperature of the gas and steel obtained by regulating the temperature setting of the chiller and hot plate respectively enabled the water condensation process to be simulated. Throughout the 7-days of experiments, the gas and steel temperature were daily monitored and the water that only condensed on the surface of the coupons was collected and measured. Subsequently, the WCR was determined. The first objective was achieved as the result from GC-MS showed that there were 67 compounds in the condensate, and 5 functional groups were detected using FTIR, which confirmed that the gas condensate used in this experiment was similar to the gas condensate obtained from the pipelines. The second objective proved the condensate affected the water condensation rate, in which the WCR was reduced by about 73% with the presence of condensate. This WCR reduction is postulated because of the two different liquids (water and hydrocarbon) competing for the same surface area (top metal coupon) to condense. © 2023 Trans Tech Publications Ltd, Switzerland. Trans Tech Publications Ltd 10139826 English Book chapter |
author |
Husna H.J.; Wan Nurmi S.W.A.; Mohd Rizuan M.R.; Adli M.N.; Najmiddin Y. |
spellingShingle |
Husna H.J.; Wan Nurmi S.W.A.; Mohd Rizuan M.R.; Adli M.N.; Najmiddin Y. Effect of the Water Condensation Rate with the Presence of Gas Condensate in the Wet Gas Pipeline |
author_facet |
Husna H.J.; Wan Nurmi S.W.A.; Mohd Rizuan M.R.; Adli M.N.; Najmiddin Y. |
author_sort |
Husna H.J.; Wan Nurmi S.W.A.; Mohd Rizuan M.R.; Adli M.N.; Najmiddin Y. |
title |
Effect of the Water Condensation Rate with the Presence of Gas Condensate in the Wet Gas Pipeline |
title_short |
Effect of the Water Condensation Rate with the Presence of Gas Condensate in the Wet Gas Pipeline |
title_full |
Effect of the Water Condensation Rate with the Presence of Gas Condensate in the Wet Gas Pipeline |
title_fullStr |
Effect of the Water Condensation Rate with the Presence of Gas Condensate in the Wet Gas Pipeline |
title_full_unstemmed |
Effect of the Water Condensation Rate with the Presence of Gas Condensate in the Wet Gas Pipeline |
title_sort |
Effect of the Water Condensation Rate with the Presence of Gas Condensate in the Wet Gas Pipeline |
publishDate |
2023 |
container_title |
Key Engineering Materials |
container_volume |
939 |
container_issue |
|
doi_str_mv |
10.4028/p-609529 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85163694400&doi=10.4028%2fp-609529&partnerID=40&md5=51b849839819bfdcee8484c6c0d9223f |
description |
Pipelines are common medium to transfer hydrocarbons, but their integrity are compromised with the corrosion issues specifically in top of line corrosion (TLC) due to several influence factors such as water condensation. Water condensation occurs due to a significant variance in temperature outside the pipeline and inside the pipeline as water condenses in the inner pipeline. Hence, this paper aims to study the water condensation rate (WCR) behaviour in the presence of gas condensate in wet gas pipelines. The objectives of the research are to determine the components of the gas condensate by characterizing the gas condensate using Gas Chromatography–Mass Spectrometry (GC-MS) and Fourier-Transform Infrared Spectroscopy (FTIR) equipment and later to determine the effect of gas condensate on water condensation rate by conducting 2 different experiments. The condition of TLC was imitated by using a customized TLC testing unit, whereby 2 sets of API 5L X65 carbon steel coupons were used. Meanwhile, the delta temperature of the gas and steel obtained by regulating the temperature setting of the chiller and hot plate respectively enabled the water condensation process to be simulated. Throughout the 7-days of experiments, the gas and steel temperature were daily monitored and the water that only condensed on the surface of the coupons was collected and measured. Subsequently, the WCR was determined. The first objective was achieved as the result from GC-MS showed that there were 67 compounds in the condensate, and 5 functional groups were detected using FTIR, which confirmed that the gas condensate used in this experiment was similar to the gas condensate obtained from the pipelines. The second objective proved the condensate affected the water condensation rate, in which the WCR was reduced by about 73% with the presence of condensate. This WCR reduction is postulated because of the two different liquids (water and hydrocarbon) competing for the same surface area (top metal coupon) to condense. © 2023 Trans Tech Publications Ltd, Switzerland. |