FEA-Based Simulation of Accelerated Ageing in a Power Cable Due to Sustained Partial Discharge Activities in a Spherical Cavity

The reliability of electrical assets is greatly influenced by the quality of their insulations. Key power installations such as power cables are manufactured with polymer-based materials as part of their insulation system. However, accelerated ageing of equipment insulations due to manifestation of...

Full description

Bibliographic Details
Published in:Arabian Journal for Science and Engineering
Main Author: Musa U.; Mati A.A.; Mas’ud A.A.; Shehu G.S.; Rodríguez-Serna J.M.; Al-Shammari S.J.; Rohani M.N.K.H.; Muhammad-Sukki F.
Format: Article
Language:English
Published: Institute for Ionics 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85161823092&doi=10.1007%2fs13369-023-07967-7&partnerID=40&md5=9a013776eb6faec74cd550a6cbb46e7d
id 2-s2.0-85161823092
spelling 2-s2.0-85161823092
Musa U.; Mati A.A.; Mas’ud A.A.; Shehu G.S.; Rodríguez-Serna J.M.; Al-Shammari S.J.; Rohani M.N.K.H.; Muhammad-Sukki F.
FEA-Based Simulation of Accelerated Ageing in a Power Cable Due to Sustained Partial Discharge Activities in a Spherical Cavity
2023
Arabian Journal for Science and Engineering
48
11
10.1007/s13369-023-07967-7
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85161823092&doi=10.1007%2fs13369-023-07967-7&partnerID=40&md5=9a013776eb6faec74cd550a6cbb46e7d
The reliability of electrical assets is greatly influenced by the quality of their insulations. Key power installations such as power cables are manufactured with polymer-based materials as part of their insulation system. However, accelerated ageing of equipment insulations due to manifestation of defect(s), and partial discharges (PDs) can offset the operation of these systems or even lead to breakdowns. In this study, a non-deterministic model to simulate the phenomenon of repetitive discharges in a spherical air-filled cavity within a practical power cable has been investigated. In addition, the work contributes to the understanding of PD behaviour and field distribution under different ageing conditions considering changes in cavity surface conductivity. First, a section of the practical XLPE cable containing the cavity is developed in 2D using COMSOL software, and a finite element analysis (FEA) of the electric field distribution within the cable insulation is performed. The magnitude of the cavity local field, that is enough to ignite a PD, is investigated. Alongside the COMSOL model, the activity of sustained internal PD is simulated in MATLAB by introducing a random sample generating factor and adjusting the model’s parameters to obtain something close to the practical results. Furthermore, the impact of continuous PD in the power cable under different cavity dimensions and surface conductivity is likewise investigated, and a phase resolved PD (PRPD) pattern is established. The result shows that the magnitude and number of PDs per cycle increase as the cavity size and its surface conductivity increase. Finally, when the cavity surface conductivity rises, the amplitude of the electric field generated by the surface charge distribution and the number of PDs per cycle approach their maximum values. © 2023, The Author(s).
Institute for Ionics
2193567X
English
Article
All Open Access; Hybrid Gold Open Access
author Musa U.; Mati A.A.; Mas’ud A.A.; Shehu G.S.; Rodríguez-Serna J.M.; Al-Shammari S.J.; Rohani M.N.K.H.; Muhammad-Sukki F.
spellingShingle Musa U.; Mati A.A.; Mas’ud A.A.; Shehu G.S.; Rodríguez-Serna J.M.; Al-Shammari S.J.; Rohani M.N.K.H.; Muhammad-Sukki F.
FEA-Based Simulation of Accelerated Ageing in a Power Cable Due to Sustained Partial Discharge Activities in a Spherical Cavity
author_facet Musa U.; Mati A.A.; Mas’ud A.A.; Shehu G.S.; Rodríguez-Serna J.M.; Al-Shammari S.J.; Rohani M.N.K.H.; Muhammad-Sukki F.
author_sort Musa U.; Mati A.A.; Mas’ud A.A.; Shehu G.S.; Rodríguez-Serna J.M.; Al-Shammari S.J.; Rohani M.N.K.H.; Muhammad-Sukki F.
title FEA-Based Simulation of Accelerated Ageing in a Power Cable Due to Sustained Partial Discharge Activities in a Spherical Cavity
title_short FEA-Based Simulation of Accelerated Ageing in a Power Cable Due to Sustained Partial Discharge Activities in a Spherical Cavity
title_full FEA-Based Simulation of Accelerated Ageing in a Power Cable Due to Sustained Partial Discharge Activities in a Spherical Cavity
title_fullStr FEA-Based Simulation of Accelerated Ageing in a Power Cable Due to Sustained Partial Discharge Activities in a Spherical Cavity
title_full_unstemmed FEA-Based Simulation of Accelerated Ageing in a Power Cable Due to Sustained Partial Discharge Activities in a Spherical Cavity
title_sort FEA-Based Simulation of Accelerated Ageing in a Power Cable Due to Sustained Partial Discharge Activities in a Spherical Cavity
publishDate 2023
container_title Arabian Journal for Science and Engineering
container_volume 48
container_issue 11
doi_str_mv 10.1007/s13369-023-07967-7
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85161823092&doi=10.1007%2fs13369-023-07967-7&partnerID=40&md5=9a013776eb6faec74cd550a6cbb46e7d
description The reliability of electrical assets is greatly influenced by the quality of their insulations. Key power installations such as power cables are manufactured with polymer-based materials as part of their insulation system. However, accelerated ageing of equipment insulations due to manifestation of defect(s), and partial discharges (PDs) can offset the operation of these systems or even lead to breakdowns. In this study, a non-deterministic model to simulate the phenomenon of repetitive discharges in a spherical air-filled cavity within a practical power cable has been investigated. In addition, the work contributes to the understanding of PD behaviour and field distribution under different ageing conditions considering changes in cavity surface conductivity. First, a section of the practical XLPE cable containing the cavity is developed in 2D using COMSOL software, and a finite element analysis (FEA) of the electric field distribution within the cable insulation is performed. The magnitude of the cavity local field, that is enough to ignite a PD, is investigated. Alongside the COMSOL model, the activity of sustained internal PD is simulated in MATLAB by introducing a random sample generating factor and adjusting the model’s parameters to obtain something close to the practical results. Furthermore, the impact of continuous PD in the power cable under different cavity dimensions and surface conductivity is likewise investigated, and a phase resolved PD (PRPD) pattern is established. The result shows that the magnitude and number of PDs per cycle increase as the cavity size and its surface conductivity increase. Finally, when the cavity surface conductivity rises, the amplitude of the electric field generated by the surface charge distribution and the number of PDs per cycle approach their maximum values. © 2023, The Author(s).
publisher Institute for Ionics
issn 2193567X
language English
format Article
accesstype All Open Access; Hybrid Gold Open Access
record_format scopus
collection Scopus
_version_ 1809678156156633088