Experimental Bond Behaviour of Glued-In Rod Connection for Mengkulang Glulam under Pull-Out Loading

Mechanical joint and adhesive joint are the two most common types of timber connections. In the case of timber construction, bonded-in rods offer a long-term, aesthetically acceptable alternative to some of the more conventional steel moment connections. Bonded-in rod connections in timber need many...

Full description

Bibliographic Details
Published in:Civil Engineering and Architecture
Main Author: Hussin T.A.R.; Hassan R.; Awaludin A.; Sidek M.N.M.; Hamid N.H.A.; Salit M.S.
Format: Article
Language:English
Published: Horizon Research Publishing 2022
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85156242556&doi=10.13189%2fcea.2022.100322&partnerID=40&md5=6fba0f9c2ef489240c6e59e8008335d2
id 2-s2.0-85156242556
spelling 2-s2.0-85156242556
Hussin T.A.R.; Hassan R.; Awaludin A.; Sidek M.N.M.; Hamid N.H.A.; Salit M.S.
Experimental Bond Behaviour of Glued-In Rod Connection for Mengkulang Glulam under Pull-Out Loading
2022
Civil Engineering and Architecture
10
3
10.13189/cea.2022.100322
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85156242556&doi=10.13189%2fcea.2022.100322&partnerID=40&md5=6fba0f9c2ef489240c6e59e8008335d2
Mechanical joint and adhesive joint are the two most common types of timber connections. In the case of timber construction, bonded-in rods offer a long-term, aesthetically acceptable alternative to some of the more conventional steel moment connections. Bonded-in rod connections in timber need many desirable attributes inefficiency, manufacture, performance, aesthetics and cost. This paper presents pull-out experimental testing for glued-in rod made of Mengkulang (tarrietia javanica) glulam joints. Hundred and seven (107) specimens were prepared, each with a single glued-in rod parallel and perpendicular to the grain. The steel treaded rod with a diameter of 12 mm, 16 mm and 20 mm with three numbers of adhesive (Sikadur-30) thicknesses of 2 mm, 3 mm and 4 mm were used in this experiment. The pull-out tests observations were on the effects of adhesive thickness, parallel and perpendicular grain directions and modes of failure of the specimens. The result obtained that 4 mm adhesive thickness was the strongest and parallel specimens showed better results than the perpendicular specimens. The pull-out failure modes are affected by the selected factors, i.e. the adhesive thickness, rod diameter and grain directions. Most of the specimens show failures in the timber besides the adhesive to timber interface. © 2022 by authors. All rights reserved.
Horizon Research Publishing
23321091
English
Article
All Open Access; Gold Open Access
author Hussin T.A.R.; Hassan R.; Awaludin A.; Sidek M.N.M.; Hamid N.H.A.; Salit M.S.
spellingShingle Hussin T.A.R.; Hassan R.; Awaludin A.; Sidek M.N.M.; Hamid N.H.A.; Salit M.S.
Experimental Bond Behaviour of Glued-In Rod Connection for Mengkulang Glulam under Pull-Out Loading
author_facet Hussin T.A.R.; Hassan R.; Awaludin A.; Sidek M.N.M.; Hamid N.H.A.; Salit M.S.
author_sort Hussin T.A.R.; Hassan R.; Awaludin A.; Sidek M.N.M.; Hamid N.H.A.; Salit M.S.
title Experimental Bond Behaviour of Glued-In Rod Connection for Mengkulang Glulam under Pull-Out Loading
title_short Experimental Bond Behaviour of Glued-In Rod Connection for Mengkulang Glulam under Pull-Out Loading
title_full Experimental Bond Behaviour of Glued-In Rod Connection for Mengkulang Glulam under Pull-Out Loading
title_fullStr Experimental Bond Behaviour of Glued-In Rod Connection for Mengkulang Glulam under Pull-Out Loading
title_full_unstemmed Experimental Bond Behaviour of Glued-In Rod Connection for Mengkulang Glulam under Pull-Out Loading
title_sort Experimental Bond Behaviour of Glued-In Rod Connection for Mengkulang Glulam under Pull-Out Loading
publishDate 2022
container_title Civil Engineering and Architecture
container_volume 10
container_issue 3
doi_str_mv 10.13189/cea.2022.100322
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85156242556&doi=10.13189%2fcea.2022.100322&partnerID=40&md5=6fba0f9c2ef489240c6e59e8008335d2
description Mechanical joint and adhesive joint are the two most common types of timber connections. In the case of timber construction, bonded-in rods offer a long-term, aesthetically acceptable alternative to some of the more conventional steel moment connections. Bonded-in rod connections in timber need many desirable attributes inefficiency, manufacture, performance, aesthetics and cost. This paper presents pull-out experimental testing for glued-in rod made of Mengkulang (tarrietia javanica) glulam joints. Hundred and seven (107) specimens were prepared, each with a single glued-in rod parallel and perpendicular to the grain. The steel treaded rod with a diameter of 12 mm, 16 mm and 20 mm with three numbers of adhesive (Sikadur-30) thicknesses of 2 mm, 3 mm and 4 mm were used in this experiment. The pull-out tests observations were on the effects of adhesive thickness, parallel and perpendicular grain directions and modes of failure of the specimens. The result obtained that 4 mm adhesive thickness was the strongest and parallel specimens showed better results than the perpendicular specimens. The pull-out failure modes are affected by the selected factors, i.e. the adhesive thickness, rod diameter and grain directions. Most of the specimens show failures in the timber besides the adhesive to timber interface. © 2022 by authors. All rights reserved.
publisher Horizon Research Publishing
issn 23321091
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809677684534411264