Gold Nanoparticle Deposited on Screen-Printed Carbon Electrode for Electrochemical Detection of Nicotine in E-cigarette

Nicotine addiction is a global health problem that causes 4.9 million deaths each year. Nicotine addiction from smoking tobacco may harm both active and passive smokers. Due to nicotine’s slow electrode kinetics and redox response occurring at positive potentials, there has been a need in designing...

Full description

Bibliographic Details
Published in:Malaysian Journal of Chemistry
Main Author: Ali Amran A.A.; Chin L.Y.; Azman N.; Jafar N.; Mohd Y.; Rahim R.A.; Nordin A.N.; Zain Z.M.
Format: Article
Language:English
Published: Malaysian Institute of Chemistry 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85153607026&doi=10.55373%2fmjchem.v25i2.1&partnerID=40&md5=fca36933d2d61a8170508e2a5659d68c
id 2-s2.0-85153607026
spelling 2-s2.0-85153607026
Ali Amran A.A.; Chin L.Y.; Azman N.; Jafar N.; Mohd Y.; Rahim R.A.; Nordin A.N.; Zain Z.M.
Gold Nanoparticle Deposited on Screen-Printed Carbon Electrode for Electrochemical Detection of Nicotine in E-cigarette
2023
Malaysian Journal of Chemistry
25
2
10.55373/mjchem.v25i2.1
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85153607026&doi=10.55373%2fmjchem.v25i2.1&partnerID=40&md5=fca36933d2d61a8170508e2a5659d68c
Nicotine addiction is a global health problem that causes 4.9 million deaths each year. Nicotine addiction from smoking tobacco may harm both active and passive smokers. Due to nicotine’s slow electrode kinetics and redox response occurring at positive potentials, there has been a need in designing electrode material for narrowing the electrochemical window for nicotine redox reaction on the current-potential curve. Nicotine oxidation happens at a higher potential making the signal susceptible to interference from oxygen, thus causing inconsistency in the electrochemical signal. Numerous electrode modifications have been attempted to solve the problem of nicotine’s substantial overpotential on bare carbon electrodes. In this work, nicotine in e-cigarette tobacco products was detected using gold nanoparticles electrodeposited on screen-printed carbon electrode (AuNPs-SPCE). The gold solution was prepared from a precursor solution of 10 mM chloroauric acid, HAuCl4. The screen-printed carbon electrode (SPCE) was immersed in the gold solution and was selectively electrodeposited on the SPCE surface at a potential of +0.53 V as the first layer deposition by using chronoamperometry (CA). Then, CA was performed at a constant potential of –0.9 V for approximately 900 seconds on the SPCE surface, resulting in a second layer with gold nanostructures. The gold nanostructures were characterised by using Scanning Electron Microscopy (SEM) and Elemental Dispersive X-ray Spectroscopy (EDX). The electrochemical analysis was proceeded using the fabricated AuNPs-SPCE as the working electrode in potassium ferrocyanide, K4Fe(CN)6, standard nicotine in 0.1 M PBS (pH 7), and liquid-flavoured e-cigarette (sample) using the cyclic voltammetry (CV) method. The effectiveness of the AuNPs-SPCE shows the detection of nicotine at a potential +0.2 V focusing on nicotine’s oxidation peak. The oxidation peak calibration graph was linear from 0.00025 M to 0.03 M, with a correlation coefficient (R2) of 0.9920 and a limit detection of 8.3 mM within 2 secs of response time. This preliminary finding can contribute to the health care community in diagnosing nicotine addiction at an early stage to prevent tragic nicotine overdoses. © 2023 Malaysian Institute of Chemistry. All rights reserved.
Malaysian Institute of Chemistry
15112292
English
Article
All Open Access; Green Open Access
author Ali Amran A.A.; Chin L.Y.; Azman N.; Jafar N.; Mohd Y.; Rahim R.A.; Nordin A.N.; Zain Z.M.
spellingShingle Ali Amran A.A.; Chin L.Y.; Azman N.; Jafar N.; Mohd Y.; Rahim R.A.; Nordin A.N.; Zain Z.M.
Gold Nanoparticle Deposited on Screen-Printed Carbon Electrode for Electrochemical Detection of Nicotine in E-cigarette
author_facet Ali Amran A.A.; Chin L.Y.; Azman N.; Jafar N.; Mohd Y.; Rahim R.A.; Nordin A.N.; Zain Z.M.
author_sort Ali Amran A.A.; Chin L.Y.; Azman N.; Jafar N.; Mohd Y.; Rahim R.A.; Nordin A.N.; Zain Z.M.
title Gold Nanoparticle Deposited on Screen-Printed Carbon Electrode for Electrochemical Detection of Nicotine in E-cigarette
title_short Gold Nanoparticle Deposited on Screen-Printed Carbon Electrode for Electrochemical Detection of Nicotine in E-cigarette
title_full Gold Nanoparticle Deposited on Screen-Printed Carbon Electrode for Electrochemical Detection of Nicotine in E-cigarette
title_fullStr Gold Nanoparticle Deposited on Screen-Printed Carbon Electrode for Electrochemical Detection of Nicotine in E-cigarette
title_full_unstemmed Gold Nanoparticle Deposited on Screen-Printed Carbon Electrode for Electrochemical Detection of Nicotine in E-cigarette
title_sort Gold Nanoparticle Deposited on Screen-Printed Carbon Electrode for Electrochemical Detection of Nicotine in E-cigarette
publishDate 2023
container_title Malaysian Journal of Chemistry
container_volume 25
container_issue 2
doi_str_mv 10.55373/mjchem.v25i2.1
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85153607026&doi=10.55373%2fmjchem.v25i2.1&partnerID=40&md5=fca36933d2d61a8170508e2a5659d68c
description Nicotine addiction is a global health problem that causes 4.9 million deaths each year. Nicotine addiction from smoking tobacco may harm both active and passive smokers. Due to nicotine’s slow electrode kinetics and redox response occurring at positive potentials, there has been a need in designing electrode material for narrowing the electrochemical window for nicotine redox reaction on the current-potential curve. Nicotine oxidation happens at a higher potential making the signal susceptible to interference from oxygen, thus causing inconsistency in the electrochemical signal. Numerous electrode modifications have been attempted to solve the problem of nicotine’s substantial overpotential on bare carbon electrodes. In this work, nicotine in e-cigarette tobacco products was detected using gold nanoparticles electrodeposited on screen-printed carbon electrode (AuNPs-SPCE). The gold solution was prepared from a precursor solution of 10 mM chloroauric acid, HAuCl4. The screen-printed carbon electrode (SPCE) was immersed in the gold solution and was selectively electrodeposited on the SPCE surface at a potential of +0.53 V as the first layer deposition by using chronoamperometry (CA). Then, CA was performed at a constant potential of –0.9 V for approximately 900 seconds on the SPCE surface, resulting in a second layer with gold nanostructures. The gold nanostructures were characterised by using Scanning Electron Microscopy (SEM) and Elemental Dispersive X-ray Spectroscopy (EDX). The electrochemical analysis was proceeded using the fabricated AuNPs-SPCE as the working electrode in potassium ferrocyanide, K4Fe(CN)6, standard nicotine in 0.1 M PBS (pH 7), and liquid-flavoured e-cigarette (sample) using the cyclic voltammetry (CV) method. The effectiveness of the AuNPs-SPCE shows the detection of nicotine at a potential +0.2 V focusing on nicotine’s oxidation peak. The oxidation peak calibration graph was linear from 0.00025 M to 0.03 M, with a correlation coefficient (R2) of 0.9920 and a limit detection of 8.3 mM within 2 secs of response time. This preliminary finding can contribute to the health care community in diagnosing nicotine addiction at an early stage to prevent tragic nicotine overdoses. © 2023 Malaysian Institute of Chemistry. All rights reserved.
publisher Malaysian Institute of Chemistry
issn 15112292
language English
format Article
accesstype All Open Access; Green Open Access
record_format scopus
collection Scopus
_version_ 1809678021460754432