FTIR conformity analysis and performance testings of fresh, aged and expired polymeric paints under different storage conditions
This study aims to correlate the molecular structure consistency of unmixed paints and the performance of 2-pack three-layer protective dried coatings (mixed and cured paints) in various aging conditions (fresh, aged and expired paints) stored under different conditions. All the physical tests (dens...
Published in: | Pure and Applied Chemistry |
---|---|
Main Author: | |
Format: | Conference paper |
Language: | English |
Published: |
De Gruyter Open Ltd
2023
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85149545078&doi=10.1515%2fpac-2022-0901&partnerID=40&md5=081e5edad18f05a15d7edc3c6b122a4d |
id |
2-s2.0-85149545078 |
---|---|
spelling |
2-s2.0-85149545078 Abd Rashid N.; Salim Y.S.; Abdul Halim S.I.; Harun M.K.; Ong C.H.; Chan C.H. FTIR conformity analysis and performance testings of fresh, aged and expired polymeric paints under different storage conditions 2023 Pure and Applied Chemistry 95 2 10.1515/pac-2022-0901 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85149545078&doi=10.1515%2fpac-2022-0901&partnerID=40&md5=081e5edad18f05a15d7edc3c6b122a4d This study aims to correlate the molecular structure consistency of unmixed paints and the performance of 2-pack three-layer protective dried coatings (mixed and cured paints) in various aging conditions (fresh, aged and expired paints) stored under different conditions. All the physical tests (density, solid content, viscosity and sag resistance) of paints fulfil the required specifications. However, these tests cannot tell if the chemical formulation of retained paints (aged and expired) has undergone changes due to storage. The conformity analysis by Fourier-transform infrared (FTIR) spectroscopy coupled with squared derivative algorithm was employed for molecular structure analysis comparison of the fresh and retained paints. FTIR results show high degree of similarity (r), with r ≥ 0.900 for the properly stored retained paints when compared against its fresh paints using high sensitivity compare algorithm. This finding is validated with a paired Student's t-test and it turns out that the r values of properly stored paints are not statistically different from the fresh paints. Moreover, the performance test (pull off adhesion and salt-spray) of dried coatings indicates good durability when the properly stored retained paints with high degree of structural similarity are applied on the substrate according to end user specifications. This approach offers a practical solution for the paint manufacturer and user to employ a rapid and non-destructive FTIR structural analysis for the confirmation of structural consistency of retained paints before application instead of disposing the polymeric paint without verification. © 2023 IUPAC & De Gruyter. This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. For more information, please visit: http://creativecommons.org/licenses/by-nc-nd/4.0/. De Gruyter Open Ltd 334545 English Conference paper All Open Access; Hybrid Gold Open Access |
author |
Abd Rashid N.; Salim Y.S.; Abdul Halim S.I.; Harun M.K.; Ong C.H.; Chan C.H. |
spellingShingle |
Abd Rashid N.; Salim Y.S.; Abdul Halim S.I.; Harun M.K.; Ong C.H.; Chan C.H. FTIR conformity analysis and performance testings of fresh, aged and expired polymeric paints under different storage conditions |
author_facet |
Abd Rashid N.; Salim Y.S.; Abdul Halim S.I.; Harun M.K.; Ong C.H.; Chan C.H. |
author_sort |
Abd Rashid N.; Salim Y.S.; Abdul Halim S.I.; Harun M.K.; Ong C.H.; Chan C.H. |
title |
FTIR conformity analysis and performance testings of fresh, aged and expired polymeric paints under different storage conditions |
title_short |
FTIR conformity analysis and performance testings of fresh, aged and expired polymeric paints under different storage conditions |
title_full |
FTIR conformity analysis and performance testings of fresh, aged and expired polymeric paints under different storage conditions |
title_fullStr |
FTIR conformity analysis and performance testings of fresh, aged and expired polymeric paints under different storage conditions |
title_full_unstemmed |
FTIR conformity analysis and performance testings of fresh, aged and expired polymeric paints under different storage conditions |
title_sort |
FTIR conformity analysis and performance testings of fresh, aged and expired polymeric paints under different storage conditions |
publishDate |
2023 |
container_title |
Pure and Applied Chemistry |
container_volume |
95 |
container_issue |
2 |
doi_str_mv |
10.1515/pac-2022-0901 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85149545078&doi=10.1515%2fpac-2022-0901&partnerID=40&md5=081e5edad18f05a15d7edc3c6b122a4d |
description |
This study aims to correlate the molecular structure consistency of unmixed paints and the performance of 2-pack three-layer protective dried coatings (mixed and cured paints) in various aging conditions (fresh, aged and expired paints) stored under different conditions. All the physical tests (density, solid content, viscosity and sag resistance) of paints fulfil the required specifications. However, these tests cannot tell if the chemical formulation of retained paints (aged and expired) has undergone changes due to storage. The conformity analysis by Fourier-transform infrared (FTIR) spectroscopy coupled with squared derivative algorithm was employed for molecular structure analysis comparison of the fresh and retained paints. FTIR results show high degree of similarity (r), with r ≥ 0.900 for the properly stored retained paints when compared against its fresh paints using high sensitivity compare algorithm. This finding is validated with a paired Student's t-test and it turns out that the r values of properly stored paints are not statistically different from the fresh paints. Moreover, the performance test (pull off adhesion and salt-spray) of dried coatings indicates good durability when the properly stored retained paints with high degree of structural similarity are applied on the substrate according to end user specifications. This approach offers a practical solution for the paint manufacturer and user to employ a rapid and non-destructive FTIR structural analysis for the confirmation of structural consistency of retained paints before application instead of disposing the polymeric paint without verification. © 2023 IUPAC & De Gruyter. This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. For more information, please visit: http://creativecommons.org/licenses/by-nc-nd/4.0/. |
publisher |
De Gruyter Open Ltd |
issn |
334545 |
language |
English |
format |
Conference paper |
accesstype |
All Open Access; Hybrid Gold Open Access |
record_format |
scopus |
collection |
Scopus |
_version_ |
1809678017440514048 |