Numerical Investigation of Flow and Dispersion over Two-Dimensional Semi-Open Street Canyon

A semi-open street canyon is able to protect pedestrians from unpleasant situations such as direct sunlight and rain. However, the protruding elements of the two opposite building facades that form the semi-open configuration can affect the air quality of the urban canopy layer (UCL). Therefore, thi...

Full description

Bibliographic Details
Published in:CFD Letters
Main Author: Ibrahim M.F.; Mohamad M.F.; Ikegaya N.; Razak A.A.
Format: Article
Language:English
Published: Penerbit Akademia Baru 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85147021311&doi=10.37934%2fcfdl.15.2.5370&partnerID=40&md5=632589794d7d8914d6aebfce1993bbe3
Description
Summary:A semi-open street canyon is able to protect pedestrians from unpleasant situations such as direct sunlight and rain. However, the protruding elements of the two opposite building facades that form the semi-open configuration can affect the air quality of the urban canopy layer (UCL). Therefore, this paper investigated the influence of the eave structures on the flow and pollutant dispersion over an idealized 2D street canyon with a unity aspect ratio. The length of the eaves was varied into 0.25H and 0.5H (H is the building height) and placed either on the leeward wall, the windward wall, or on both building facades located at the same elevation as the street canyon. Numerical simulations were performed using the steady-state Reynolds-averaged Navier-Stokes (RANS) equations in conjunction with Re-Normalization Group (RNG) k-ε as the turbulence closure model. The pollutant was released from a line source in the center of the bottom of the target canyon with uniform flow rate. Six different eave configurations were simulated in the wind direction perpendicular to the canyon axis, representing the worst condition of canyon ventilation. The evolution of the primary vortex, which occupied the entire canyon with the characteristic of skimming flow, showed less dependence on the length and position of the eave, except for the longest eave on the windward wall. However, the position of the vortex center depicted opposite results. The pollutant concentration is always higher near the leeward wall, but for the eave that protrudes from the windward wall with a length of 0.5H, the pollutant accumulates near the windward region. The ratio of pollutant concentration showed higher concentration in the semi-open configurations compared to the fully open layout as a result of limited penetration of shear flow into the canyon, which leads to deterioration of pollutant removal. © 2023, Penerbit Akademia Baru. All rights reserved.
ISSN:21801363
DOI:10.37934/cfdl.15.2.5370