A highly sensitive LC-MS/MS method for quantitative determination of 7 vitamin D metabolites in mouse brain tissue

Despite its critical role in neurodevelopment and brain function, vitamin D (vit-D) homeostasis, metabolism, and kinetics within the central nervous system remain largely undetermined. Thus, it is of critical importance to establish an accurate, highly sensitive, and reproducible method to quantitat...

Full description

Bibliographic Details
Published in:Analytical and Bioanalytical Chemistry
Main Author: Stephenson A.J.; Hunter B.; Shaw P.N.; Kassim N.S.A.; Trengove R.; Takechi R.; Lam V.; Mamo J.
Format: Article
Language:English
Published: Springer Science and Business Media Deutschland GmbH 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146923924&doi=10.1007%2fs00216-023-04527-8&partnerID=40&md5=0e6fe27f2603a1d0c61135f8eb1811bd
id 2-s2.0-85146923924
spelling 2-s2.0-85146923924
Stephenson A.J.; Hunter B.; Shaw P.N.; Kassim N.S.A.; Trengove R.; Takechi R.; Lam V.; Mamo J.
A highly sensitive LC-MS/MS method for quantitative determination of 7 vitamin D metabolites in mouse brain tissue
2023
Analytical and Bioanalytical Chemistry
415
7
10.1007/s00216-023-04527-8
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146923924&doi=10.1007%2fs00216-023-04527-8&partnerID=40&md5=0e6fe27f2603a1d0c61135f8eb1811bd
Despite its critical role in neurodevelopment and brain function, vitamin D (vit-D) homeostasis, metabolism, and kinetics within the central nervous system remain largely undetermined. Thus, it is of critical importance to establish an accurate, highly sensitive, and reproducible method to quantitate vit-D in brain tissue. Here, we present a novel liquid chromatography tandem mass spectrometry (LC-MS/MS) method and for the first time, demonstrate detection of seven major vit-D metabolites in brain tissues of C57BL/6J wild-type mice, namely 1,25(OH)2D3, 3-epi-1,25(OH)2D3, 1,25(OH)2D2, 25(OH)D3, 25(OH)D2, 24,25(OH)2D3, and 24,25(OH)2D2. Chromatographic separation was achieved on a pentaflurophenyl column with 3 mM ammonium formate water/methanol [A] and 3 mM ammonium formate methanol/isopropanol [B] mobile phase components. Detection was by positive ion electrospray tandem mass spectrometry with the EVOQ elite triple quadrupole mass spectrometer with an Advance ultra-high-performance liquid chromatograph and online extraction system. Calibration standards of each metabolite prepared in brain matrices were used to validate the detection range, precision, accuracy, and recovery. Isotopically labelled analogues, 1,25(OH)2D3-d3, 25(OH)D3-c5, and 24,25(OH)2D3-d6, served as the internal standards for the closest molecular-related metabolite in all measurements. Standards between 1 fg/mL and 10 ng/mL were injected with a resulting linear range between 0.001 and 1 ng, with an LLOD and LLOQ of 1 pg/mL and 12.5 pg/mL, respectively. The intra-/inter-day precision and accuracy for measuring brain vit-D metabolites ranged between 0.12–11.53% and 0.28–9.11%, respectively. Recovery in acetonitrile ranged between 99.09 and 106.92% for all metabolites. Collectively, the sensitivity and efficiency of our method supersedes previously reported protocols used to measure vit-D and to our knowledge, the first protocol to reveal the abundance of 25(OH)D2, 1,25(OH)D2, and 24,25(OH)2D2, in brain tissue of any species. This technique may be important in supporting the future advancement of pre-clinical research into the function of vit-D in neurophysiological and neuropsychiatric disorders, and neurodegeneration. Graphical Abstract: [Figure not available: see fulltext.]. © 2023, The Author(s).
Springer Science and Business Media Deutschland GmbH
16182642
English
Article
All Open Access; Hybrid Gold Open Access
author Stephenson A.J.; Hunter B.; Shaw P.N.; Kassim N.S.A.; Trengove R.; Takechi R.; Lam V.; Mamo J.
spellingShingle Stephenson A.J.; Hunter B.; Shaw P.N.; Kassim N.S.A.; Trengove R.; Takechi R.; Lam V.; Mamo J.
A highly sensitive LC-MS/MS method for quantitative determination of 7 vitamin D metabolites in mouse brain tissue
author_facet Stephenson A.J.; Hunter B.; Shaw P.N.; Kassim N.S.A.; Trengove R.; Takechi R.; Lam V.; Mamo J.
author_sort Stephenson A.J.; Hunter B.; Shaw P.N.; Kassim N.S.A.; Trengove R.; Takechi R.; Lam V.; Mamo J.
title A highly sensitive LC-MS/MS method for quantitative determination of 7 vitamin D metabolites in mouse brain tissue
title_short A highly sensitive LC-MS/MS method for quantitative determination of 7 vitamin D metabolites in mouse brain tissue
title_full A highly sensitive LC-MS/MS method for quantitative determination of 7 vitamin D metabolites in mouse brain tissue
title_fullStr A highly sensitive LC-MS/MS method for quantitative determination of 7 vitamin D metabolites in mouse brain tissue
title_full_unstemmed A highly sensitive LC-MS/MS method for quantitative determination of 7 vitamin D metabolites in mouse brain tissue
title_sort A highly sensitive LC-MS/MS method for quantitative determination of 7 vitamin D metabolites in mouse brain tissue
publishDate 2023
container_title Analytical and Bioanalytical Chemistry
container_volume 415
container_issue 7
doi_str_mv 10.1007/s00216-023-04527-8
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146923924&doi=10.1007%2fs00216-023-04527-8&partnerID=40&md5=0e6fe27f2603a1d0c61135f8eb1811bd
description Despite its critical role in neurodevelopment and brain function, vitamin D (vit-D) homeostasis, metabolism, and kinetics within the central nervous system remain largely undetermined. Thus, it is of critical importance to establish an accurate, highly sensitive, and reproducible method to quantitate vit-D in brain tissue. Here, we present a novel liquid chromatography tandem mass spectrometry (LC-MS/MS) method and for the first time, demonstrate detection of seven major vit-D metabolites in brain tissues of C57BL/6J wild-type mice, namely 1,25(OH)2D3, 3-epi-1,25(OH)2D3, 1,25(OH)2D2, 25(OH)D3, 25(OH)D2, 24,25(OH)2D3, and 24,25(OH)2D2. Chromatographic separation was achieved on a pentaflurophenyl column with 3 mM ammonium formate water/methanol [A] and 3 mM ammonium formate methanol/isopropanol [B] mobile phase components. Detection was by positive ion electrospray tandem mass spectrometry with the EVOQ elite triple quadrupole mass spectrometer with an Advance ultra-high-performance liquid chromatograph and online extraction system. Calibration standards of each metabolite prepared in brain matrices were used to validate the detection range, precision, accuracy, and recovery. Isotopically labelled analogues, 1,25(OH)2D3-d3, 25(OH)D3-c5, and 24,25(OH)2D3-d6, served as the internal standards for the closest molecular-related metabolite in all measurements. Standards between 1 fg/mL and 10 ng/mL were injected with a resulting linear range between 0.001 and 1 ng, with an LLOD and LLOQ of 1 pg/mL and 12.5 pg/mL, respectively. The intra-/inter-day precision and accuracy for measuring brain vit-D metabolites ranged between 0.12–11.53% and 0.28–9.11%, respectively. Recovery in acetonitrile ranged between 99.09 and 106.92% for all metabolites. Collectively, the sensitivity and efficiency of our method supersedes previously reported protocols used to measure vit-D and to our knowledge, the first protocol to reveal the abundance of 25(OH)D2, 1,25(OH)D2, and 24,25(OH)2D2, in brain tissue of any species. This technique may be important in supporting the future advancement of pre-clinical research into the function of vit-D in neurophysiological and neuropsychiatric disorders, and neurodegeneration. Graphical Abstract: [Figure not available: see fulltext.]. © 2023, The Author(s).
publisher Springer Science and Business Media Deutschland GmbH
issn 16182642
language English
format Article
accesstype All Open Access; Hybrid Gold Open Access
record_format scopus
collection Scopus
_version_ 1809678156421922816