Design Optimisation of Bi-Cruciate Retaining Total Knee Arthroplasty (TKA) Prosthesis via Taguchi Methods

Total knee replacement has become a viable option for treating severe knee arthritis. The demand for more kinematically functional implants that better replicate natural knee kinematics led to the development of total knee arthroplasty (TKA), including bi-cruciate-retaining (BCR) TKA. However, optim...

Full description

Bibliographic Details
Published in:Mathematics
Main Author: Mohd Mukhtar N.Q.; Shuib S.; Anuar M.A.; Mohd Miswan M.F.; Mohd Anuar M.A.
Format: Article
Language:English
Published: MDPI 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146777617&doi=10.3390%2fmath11020312&partnerID=40&md5=c6bb7be5766fdd7650873ad0f5623ed5
id 2-s2.0-85146777617
spelling 2-s2.0-85146777617
Mohd Mukhtar N.Q.; Shuib S.; Anuar M.A.; Mohd Miswan M.F.; Mohd Anuar M.A.
Design Optimisation of Bi-Cruciate Retaining Total Knee Arthroplasty (TKA) Prosthesis via Taguchi Methods
2023
Mathematics
11
2
10.3390/math11020312
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146777617&doi=10.3390%2fmath11020312&partnerID=40&md5=c6bb7be5766fdd7650873ad0f5623ed5
Total knee replacement has become a viable option for treating severe knee arthritis. The demand for more kinematically functional implants that better replicate natural knee kinematics led to the development of total knee arthroplasty (TKA), including bi-cruciate-retaining (BCR) TKA. However, optimised design parameters of BCR TKA knee implants that can help achieve a long-term prosthetic survival rate remain unknown. Therefore, this study aimed to investigate the effect of the design parameters of BCR TKA knee implants on the mechanics of knee joints and optimise and individualise the knee implant design parameters using the Taguchi method incorporating finite element analysis. Herein, experimental factors and levels were selected and nine finite element models of BCR TKA knee implants were developed to optimise the design of the following parameters: the curvature ratio on the sagittal plane, curvature ratio on the coronal plane, and tibial slope. In addition, finite element analysis was used to determine the effect of the design parameters on the peak contact stress on ultra-high-molecular-weight polyethylene (UHMWPE) and its deformation. Consequently, among the three parameters that affect the peak contact stress and its deformation, the curvature ratio on the sagittal plane had the greatest effect (range = 10.96), followed by the curvature ratio on the coronal plane (range = 3.54), and the tibial slope (range = 2.56). The optimal design parameters for the BCR TKA knee implant were a curvature ratio of 1.5 on both the sagittal and coronal planes and a tibial slope of 5°. Under these conditions, the peak contact stress and deformation were 25.80 MPa and 0.0835 mm, respectively. The optimisation method based on finite element analysis and the Taguchi method can produce one of the highest-performing BCR TKA knee implant designs, thereby reducing the peak contact stress and deformation. This method sheds fresh light on the development of the BCR TKA knee implant as well as biomechanical decision-making to implant the TKA prosthesis correctly. © 2023 by the authors.
MDPI
22277390
English
Article
All Open Access; Gold Open Access
author Mohd Mukhtar N.Q.; Shuib S.; Anuar M.A.; Mohd Miswan M.F.; Mohd Anuar M.A.
spellingShingle Mohd Mukhtar N.Q.; Shuib S.; Anuar M.A.; Mohd Miswan M.F.; Mohd Anuar M.A.
Design Optimisation of Bi-Cruciate Retaining Total Knee Arthroplasty (TKA) Prosthesis via Taguchi Methods
author_facet Mohd Mukhtar N.Q.; Shuib S.; Anuar M.A.; Mohd Miswan M.F.; Mohd Anuar M.A.
author_sort Mohd Mukhtar N.Q.; Shuib S.; Anuar M.A.; Mohd Miswan M.F.; Mohd Anuar M.A.
title Design Optimisation of Bi-Cruciate Retaining Total Knee Arthroplasty (TKA) Prosthesis via Taguchi Methods
title_short Design Optimisation of Bi-Cruciate Retaining Total Knee Arthroplasty (TKA) Prosthesis via Taguchi Methods
title_full Design Optimisation of Bi-Cruciate Retaining Total Knee Arthroplasty (TKA) Prosthesis via Taguchi Methods
title_fullStr Design Optimisation of Bi-Cruciate Retaining Total Knee Arthroplasty (TKA) Prosthesis via Taguchi Methods
title_full_unstemmed Design Optimisation of Bi-Cruciate Retaining Total Knee Arthroplasty (TKA) Prosthesis via Taguchi Methods
title_sort Design Optimisation of Bi-Cruciate Retaining Total Knee Arthroplasty (TKA) Prosthesis via Taguchi Methods
publishDate 2023
container_title Mathematics
container_volume 11
container_issue 2
doi_str_mv 10.3390/math11020312
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146777617&doi=10.3390%2fmath11020312&partnerID=40&md5=c6bb7be5766fdd7650873ad0f5623ed5
description Total knee replacement has become a viable option for treating severe knee arthritis. The demand for more kinematically functional implants that better replicate natural knee kinematics led to the development of total knee arthroplasty (TKA), including bi-cruciate-retaining (BCR) TKA. However, optimised design parameters of BCR TKA knee implants that can help achieve a long-term prosthetic survival rate remain unknown. Therefore, this study aimed to investigate the effect of the design parameters of BCR TKA knee implants on the mechanics of knee joints and optimise and individualise the knee implant design parameters using the Taguchi method incorporating finite element analysis. Herein, experimental factors and levels were selected and nine finite element models of BCR TKA knee implants were developed to optimise the design of the following parameters: the curvature ratio on the sagittal plane, curvature ratio on the coronal plane, and tibial slope. In addition, finite element analysis was used to determine the effect of the design parameters on the peak contact stress on ultra-high-molecular-weight polyethylene (UHMWPE) and its deformation. Consequently, among the three parameters that affect the peak contact stress and its deformation, the curvature ratio on the sagittal plane had the greatest effect (range = 10.96), followed by the curvature ratio on the coronal plane (range = 3.54), and the tibial slope (range = 2.56). The optimal design parameters for the BCR TKA knee implant were a curvature ratio of 1.5 on both the sagittal and coronal planes and a tibial slope of 5°. Under these conditions, the peak contact stress and deformation were 25.80 MPa and 0.0835 mm, respectively. The optimisation method based on finite element analysis and the Taguchi method can produce one of the highest-performing BCR TKA knee implant designs, thereby reducing the peak contact stress and deformation. This method sheds fresh light on the development of the BCR TKA knee implant as well as biomechanical decision-making to implant the TKA prosthesis correctly. © 2023 by the authors.
publisher MDPI
issn 22277390
language English
format Article
accesstype All Open Access; Gold Open Access
record_format scopus
collection Scopus
_version_ 1809678157739982848