Concentration measurement of coloured solution using optofluidic approach

In analytical process, measurement of concentration of solution based on colorimetric sensing is normally performed using commercial devices such as colorimeter and spectrophotometer. This approach has several disadvantages such as involving a large volume of reagent and analyte during testing and m...

Full description

Bibliographic Details
Published in:Journal of Physics: Conference Series
Main Author: Dali M.R.M.; Robi F.I.M.; Ahmad K.A.; Muhammad Z.; Omar A.F.; Sulaiman M.S.; Rahman M.F.A.
Format: Conference paper
Language:English
Published: Institute of Physics 2022
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146589381&doi=10.1088%2f1742-6596%2f2411%2f1%2f012005&partnerID=40&md5=253e752851611eaf8f902419caf0e1a3
id 2-s2.0-85146589381
spelling 2-s2.0-85146589381
Dali M.R.M.; Robi F.I.M.; Ahmad K.A.; Muhammad Z.; Omar A.F.; Sulaiman M.S.; Rahman M.F.A.
Concentration measurement of coloured solution using optofluidic approach
2022
Journal of Physics: Conference Series
2411
1
10.1088/1742-6596/2411/1/012005
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146589381&doi=10.1088%2f1742-6596%2f2411%2f1%2f012005&partnerID=40&md5=253e752851611eaf8f902419caf0e1a3
In analytical process, measurement of concentration of solution based on colorimetric sensing is normally performed using commercial devices such as colorimeter and spectrophotometer. This approach has several disadvantages such as involving a large volume of reagent and analyte during testing and measurement, unextendible and expensive. Such problem can be solved by replicating its function using a simple optofluidic device with capability of carrying out colorimetric testing with low volume of analyte and reagent. Other benefits of optofluidic devices platforms includes ability to be expanded for automated sensing and mixing for various analytical based reaction. The measurement device works based on the absorbance of absorbance of light, which is related to Beer-Lambert law principles with LED and photodiode as its main optical components. The samples were prepared for concentration ranges between 0.2 to 2.0 M for testing. As a result, it is observed that these concentrations produce a linear voltage calibration curve with correlation coefficient, R2 equal to 0.9944. By using the obtained calibration curve, the final absorbance calculation gives an acceptable linear absorbance concentration with R2 equal to 0.9751 for the tested samples. As a conclusion, these microfluidic platforms not only have a good measurement performance, but also have advantages in terms of its portability and have potential to be implemented for real time application. © Published under licence by IOP Publishing Ltd.
Institute of Physics
17426588
English
Conference paper

author Dali M.R.M.; Robi F.I.M.; Ahmad K.A.; Muhammad Z.; Omar A.F.; Sulaiman M.S.; Rahman M.F.A.
spellingShingle Dali M.R.M.; Robi F.I.M.; Ahmad K.A.; Muhammad Z.; Omar A.F.; Sulaiman M.S.; Rahman M.F.A.
Concentration measurement of coloured solution using optofluidic approach
author_facet Dali M.R.M.; Robi F.I.M.; Ahmad K.A.; Muhammad Z.; Omar A.F.; Sulaiman M.S.; Rahman M.F.A.
author_sort Dali M.R.M.; Robi F.I.M.; Ahmad K.A.; Muhammad Z.; Omar A.F.; Sulaiman M.S.; Rahman M.F.A.
title Concentration measurement of coloured solution using optofluidic approach
title_short Concentration measurement of coloured solution using optofluidic approach
title_full Concentration measurement of coloured solution using optofluidic approach
title_fullStr Concentration measurement of coloured solution using optofluidic approach
title_full_unstemmed Concentration measurement of coloured solution using optofluidic approach
title_sort Concentration measurement of coloured solution using optofluidic approach
publishDate 2022
container_title Journal of Physics: Conference Series
container_volume 2411
container_issue 1
doi_str_mv 10.1088/1742-6596/2411/1/012005
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146589381&doi=10.1088%2f1742-6596%2f2411%2f1%2f012005&partnerID=40&md5=253e752851611eaf8f902419caf0e1a3
description In analytical process, measurement of concentration of solution based on colorimetric sensing is normally performed using commercial devices such as colorimeter and spectrophotometer. This approach has several disadvantages such as involving a large volume of reagent and analyte during testing and measurement, unextendible and expensive. Such problem can be solved by replicating its function using a simple optofluidic device with capability of carrying out colorimetric testing with low volume of analyte and reagent. Other benefits of optofluidic devices platforms includes ability to be expanded for automated sensing and mixing for various analytical based reaction. The measurement device works based on the absorbance of absorbance of light, which is related to Beer-Lambert law principles with LED and photodiode as its main optical components. The samples were prepared for concentration ranges between 0.2 to 2.0 M for testing. As a result, it is observed that these concentrations produce a linear voltage calibration curve with correlation coefficient, R2 equal to 0.9944. By using the obtained calibration curve, the final absorbance calculation gives an acceptable linear absorbance concentration with R2 equal to 0.9751 for the tested samples. As a conclusion, these microfluidic platforms not only have a good measurement performance, but also have advantages in terms of its portability and have potential to be implemented for real time application. © Published under licence by IOP Publishing Ltd.
publisher Institute of Physics
issn 17426588
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1809678025349922816