Modelling Neutral to Ground Voltage (NTGV) considering current sourcing method and grounding wiring configuration

A ground fault event can cause the rise of neutral to ground voltage (NTGV). Excess NTGV can result in considerable costs and safety issues, especially for high-tech educational buildings, including faulty equipment operation and failure, frequent tripping, and electromagnetic interference. Hence, t...

Full description

Bibliographic Details
Published in:2022 IEEE International Conference on Power and Energy: Advancement in Power and Energy Systems towards Sustainable and Resilient Energy Supply, PECon 2022
Main Author: Mahadan M.E.; Abidin A.F.; Talib Mat Yusoh M.A.; Hairuddin M.A.
Format: Conference paper
Language:English
Published: Institute of Electrical and Electronics Engineers Inc. 2022
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146428910&doi=10.1109%2fPECon54459.2022.9988966&partnerID=40&md5=e4c92390a6c330440e2a7b434385a688
id 2-s2.0-85146428910
spelling 2-s2.0-85146428910
Mahadan M.E.; Abidin A.F.; Talib Mat Yusoh M.A.; Hairuddin M.A.
Modelling Neutral to Ground Voltage (NTGV) considering current sourcing method and grounding wiring configuration
2022
2022 IEEE International Conference on Power and Energy: Advancement in Power and Energy Systems towards Sustainable and Resilient Energy Supply, PECon 2022


10.1109/PECon54459.2022.9988966
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146428910&doi=10.1109%2fPECon54459.2022.9988966&partnerID=40&md5=e4c92390a6c330440e2a7b434385a688
A ground fault event can cause the rise of neutral to ground voltage (NTGV). Excess NTGV can result in considerable costs and safety issues, especially for high-tech educational buildings, including faulty equipment operation and failure, frequent tripping, and electromagnetic interference. Hence, to explore the consequences and determinants of high NTGV due to ground fault, a reliable model must be employed. As a result, the main goal of this article is to establish the magnitude and shape of the NTGV in relation to ground current and load currents. The load at the educational building is constructed using the current sourcing technique, and the wiring parameters for the grounding system are taken into account. To validate the rate of accuracy of the simulation model, the Pearson correlation coefficient and mean square error (MSE) are utilized. The proposed method for figuring out the size and shape of the NTGV gives very similar results to real measurements. © 2022 IEEE.
Institute of Electrical and Electronics Engineers Inc.

English
Conference paper

author Mahadan M.E.; Abidin A.F.; Talib Mat Yusoh M.A.; Hairuddin M.A.
spellingShingle Mahadan M.E.; Abidin A.F.; Talib Mat Yusoh M.A.; Hairuddin M.A.
Modelling Neutral to Ground Voltage (NTGV) considering current sourcing method and grounding wiring configuration
author_facet Mahadan M.E.; Abidin A.F.; Talib Mat Yusoh M.A.; Hairuddin M.A.
author_sort Mahadan M.E.; Abidin A.F.; Talib Mat Yusoh M.A.; Hairuddin M.A.
title Modelling Neutral to Ground Voltage (NTGV) considering current sourcing method and grounding wiring configuration
title_short Modelling Neutral to Ground Voltage (NTGV) considering current sourcing method and grounding wiring configuration
title_full Modelling Neutral to Ground Voltage (NTGV) considering current sourcing method and grounding wiring configuration
title_fullStr Modelling Neutral to Ground Voltage (NTGV) considering current sourcing method and grounding wiring configuration
title_full_unstemmed Modelling Neutral to Ground Voltage (NTGV) considering current sourcing method and grounding wiring configuration
title_sort Modelling Neutral to Ground Voltage (NTGV) considering current sourcing method and grounding wiring configuration
publishDate 2022
container_title 2022 IEEE International Conference on Power and Energy: Advancement in Power and Energy Systems towards Sustainable and Resilient Energy Supply, PECon 2022
container_volume
container_issue
doi_str_mv 10.1109/PECon54459.2022.9988966
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85146428910&doi=10.1109%2fPECon54459.2022.9988966&partnerID=40&md5=e4c92390a6c330440e2a7b434385a688
description A ground fault event can cause the rise of neutral to ground voltage (NTGV). Excess NTGV can result in considerable costs and safety issues, especially for high-tech educational buildings, including faulty equipment operation and failure, frequent tripping, and electromagnetic interference. Hence, to explore the consequences and determinants of high NTGV due to ground fault, a reliable model must be employed. As a result, the main goal of this article is to establish the magnitude and shape of the NTGV in relation to ground current and load currents. The load at the educational building is constructed using the current sourcing technique, and the wiring parameters for the grounding system are taken into account. To validate the rate of accuracy of the simulation model, the Pearson correlation coefficient and mean square error (MSE) are utilized. The proposed method for figuring out the size and shape of the NTGV gives very similar results to real measurements. © 2022 IEEE.
publisher Institute of Electrical and Electronics Engineers Inc.
issn
language English
format Conference paper
accesstype
record_format scopus
collection Scopus
_version_ 1809677594573930496