Assessment of ultimate bearing capacity of the pile for jacking & rotary piling method

Techniques of pile installation such as jacking, dropping weight, vibration, and explosion were applied but these methods were discovered to have weaknesses, such as high friction resistance and high settlements. To overcome these problems, this study introduces new method of pile installation which...

Full description

Bibliographic Details
Published in:Physics and Chemistry of the Earth
Main Author: Hassan N.S.; Ibrahim A.; Alias R.; Abang Hasbollah D.Z.; Ramli A.B.
Format: Article
Language:English
Published: Elsevier Ltd 2023
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85145592994&doi=10.1016%2fj.pce.2022.103331&partnerID=40&md5=446298565aafe920325361bc11c42f37
id 2-s2.0-85145592994
spelling 2-s2.0-85145592994
Hassan N.S.; Ibrahim A.; Alias R.; Abang Hasbollah D.Z.; Ramli A.B.
Assessment of ultimate bearing capacity of the pile for jacking & rotary piling method
2023
Physics and Chemistry of the Earth
129

10.1016/j.pce.2022.103331
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85145592994&doi=10.1016%2fj.pce.2022.103331&partnerID=40&md5=446298565aafe920325361bc11c42f37
Techniques of pile installation such as jacking, dropping weight, vibration, and explosion were applied but these methods were discovered to have weaknesses, such as high friction resistance and high settlements. To overcome these problems, this study introduces new method of pile installation which is Jacking and Rotary method (J&R). The objective of this study is to determine pile behaviour for static load test using common method namely jacking (J), and a new method, J&R through the ultimate pile capacity achieved by both methods. A stainless steel 25 mm circular pile, a 50 mm circular pile and a screw pile were used as test piles for this investigation. To achieve the objectives, this study employed graphical methods such as Brinch Hansen 80% and Tangent method to determine the ultimate pile capacity for both piling installation methods. Results revealed that for jacking method, the highest ultimate pile capacity value for the 50 mm circular pile was 1.186 kN, whereas the 25 mm circular pile had the lowest pile capacity reading of 0.539 kN. Screw pile shows the reading of 1.068 kN for its pile capacity. While for J&R, the highest average for both graphical methods are screw pile with 0.683 kN, while the 50 mm circular pile produced the lowest pile capacity which was 0.491 kN. For 25 mm, pile capacity using J&R is 0.543 kN. Result shows the acceptable for J&R methods to be introduced with further investigation such as the response of pile under axial loading and others. © 2022 Elsevier Ltd
Elsevier Ltd
14747065
English
Article

author Hassan N.S.; Ibrahim A.; Alias R.; Abang Hasbollah D.Z.; Ramli A.B.
spellingShingle Hassan N.S.; Ibrahim A.; Alias R.; Abang Hasbollah D.Z.; Ramli A.B.
Assessment of ultimate bearing capacity of the pile for jacking & rotary piling method
author_facet Hassan N.S.; Ibrahim A.; Alias R.; Abang Hasbollah D.Z.; Ramli A.B.
author_sort Hassan N.S.; Ibrahim A.; Alias R.; Abang Hasbollah D.Z.; Ramli A.B.
title Assessment of ultimate bearing capacity of the pile for jacking & rotary piling method
title_short Assessment of ultimate bearing capacity of the pile for jacking & rotary piling method
title_full Assessment of ultimate bearing capacity of the pile for jacking & rotary piling method
title_fullStr Assessment of ultimate bearing capacity of the pile for jacking & rotary piling method
title_full_unstemmed Assessment of ultimate bearing capacity of the pile for jacking & rotary piling method
title_sort Assessment of ultimate bearing capacity of the pile for jacking & rotary piling method
publishDate 2023
container_title Physics and Chemistry of the Earth
container_volume 129
container_issue
doi_str_mv 10.1016/j.pce.2022.103331
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85145592994&doi=10.1016%2fj.pce.2022.103331&partnerID=40&md5=446298565aafe920325361bc11c42f37
description Techniques of pile installation such as jacking, dropping weight, vibration, and explosion were applied but these methods were discovered to have weaknesses, such as high friction resistance and high settlements. To overcome these problems, this study introduces new method of pile installation which is Jacking and Rotary method (J&R). The objective of this study is to determine pile behaviour for static load test using common method namely jacking (J), and a new method, J&R through the ultimate pile capacity achieved by both methods. A stainless steel 25 mm circular pile, a 50 mm circular pile and a screw pile were used as test piles for this investigation. To achieve the objectives, this study employed graphical methods such as Brinch Hansen 80% and Tangent method to determine the ultimate pile capacity for both piling installation methods. Results revealed that for jacking method, the highest ultimate pile capacity value for the 50 mm circular pile was 1.186 kN, whereas the 25 mm circular pile had the lowest pile capacity reading of 0.539 kN. Screw pile shows the reading of 1.068 kN for its pile capacity. While for J&R, the highest average for both graphical methods are screw pile with 0.683 kN, while the 50 mm circular pile produced the lowest pile capacity which was 0.491 kN. For 25 mm, pile capacity using J&R is 0.543 kN. Result shows the acceptable for J&R methods to be introduced with further investigation such as the response of pile under axial loading and others. © 2022 Elsevier Ltd
publisher Elsevier Ltd
issn 14747065
language English
format Article
accesstype
record_format scopus
collection Scopus
_version_ 1814778503763066880